Danner 02522
Pondmaster Pond-Mag 250 GPH Magnetic Drive Water Pump User Manual
Modell: 02522
Wichtige Sicherheitsinformationen
WARNUNG: Dieses Produkt kann Sie Chemikalien aussetzen, darunter Blei, das im US-Bundesstaat Kalifornien als krebserregend und als Ursache für Geburtsfehler oder andere Fortpflanzungsschäden gilt. Weitere Informationen finden Sie unter www.P65Warnings.ca.gov.
- Always disconnect the pump from the power supply before handling or performing any maintenance.
- Stellen Sie sicher, dass die Pumpe ordnungsgemäß geerdet ist.
- Die Pumpe darf nicht in Betrieb genommen werden, wenn das Netzkabel beschädigt ist.
- Keep children and pets away from the pump and water feature during operation.
- This pump is designed for water use only. Do not use with flammable liquids.
Produkt überview
Beschreibung
Danner Manufacturing, Inc., Pondmaster Pond-Mag Magnetic Drive Water Pumps, including the 250 GPH model, are engineered for various water movement applications. These pumps offer quiet, efficient, and reliable 24/7 performance, featuring a magnetic impeller assembly and an epoxy-encased power unit. The Pond-Mag 250 GPH pump is ideal for small to medium-sized ponds ranging from 150 to 550 gallons.
Hauptmerkmale
- Certified to UL or ETL standard for safety.
- Designed for continuous operation without seals to wear out.
- Features a magnetic impeller assembly and an epoxy encased power unit.
- Max. Watts/Amps: 24/0.4, Volts: 120 / 60Hz.
- Inlet: 1/2" FPT, Outlet: 1/2" MPT.
- Cord Length: 18'.
- Includes a rigid pre-filter.
- Operates submerged or inline.
- Equipped with a durable ceramic shaft.
Produktdiagramm

Figure 1: Internal components of the Pondmaster Pond-Mag pump.
Technische Daten
| Attribut | Wert |
|---|---|
| Marke | Danner |
| Modellnummer | 02522 |
| Farbe | Schwarz |
| Material | Acrylnitril-Butadien-Styrol (ABS) |
| Technische Daten | 4.5 Zoll L x 3.75 Zoll B x 3.5 Zoll H |
| Stromquelle | Kabelgebundene Elektrik |
| Artikelgewicht | 3.7 Pfund |
| Maximaler Durchfluss | 4.16 Gallonen pro Minute (250 GPH) |
| Einlass | 1/2" FPT |
| Auslauf | 1/2" MPT |
| Kabellänge | 18' |
Setup und Installation
The Pondmaster Pond-Mag pump can be installed either submerged in water or inline (external) depending on your application needs.
Untergetauchte Installation
- Ensure the pump is placed on a stable, level surface within the pond or water feature.
- Connect appropriate tubing to the pump's outlet (1/2" MPT) for water circulation.
- Ensure the pre-filter is securely attached to the pump's inlet to prevent debris from entering.
- Submerge the pump completely in water before connecting to power.
Inline (External) Installation
- Position the pump on a dry, stable surface near the water source.
- Connect tubing to both the inlet (1/2" FPT) and outlet (1/2" MPT) of the pump. Ensure all connections are watertight.
- The pump must be primed before initial operation in an inline setup. Consult a plumbing professional if unsure about priming procedures.
- Ensure the pump is protected from direct weather exposure if installed outdoors.

Figure 2: Danner Pondmaster Pond-Mag 250 GPH pump.

Figure 3: Rigid pre-filter for the Pondmaster pump.
Bedienungsanleitung
Once the pump is properly installed and connected to the water system, plug the power cord into a grounded electrical outlet. The pump is designed for continuous operation (24/7 performance). Ensure the pump is always submerged in water if used in a submerged application, or properly primed if used inline, to prevent dry running which can damage the unit.
Monitor the water flow to ensure optimal performance. If flow decreases, refer to the Maintenance or Troubleshooting sections.
Wartung
Regular maintenance ensures the longevity and efficient operation of your Pondmaster Pond-Mag pump.
- Vorfilterreinigung: Periodically remove and clean the rigid pre-filter to prevent clogging and maintain optimal water flow. Rinse with clean water.
- Laufradprüfung: If flow is significantly reduced, disconnect power and inspect the magnetic impeller assembly for debris or blockages. Carefully remove any obstructions.
- Wellenschmierung: Apply silicone grease to the ceramic shaft and rubber O-ring during reassembly to ensure smooth operation and seal integrity.
- Überwinterung: In freezing climates, remove the pump from the water feature before the first freeze. Clean thoroughly and store in a frost-free location.
Fehlerbehebung
| Problem | Mögliche Ursache | Lösung |
|---|---|---|
| Die Pumpe startet nicht und funktioniert nicht. | No power to the pump; Impeller jammed; Motor failure. | Check power connection and circuit breaker. Disconnect power and inspect impeller for debris. If problem persists, contact support. |
| Reduzierter Wasserdurchfluss. | Clogged pre-filter; Debris in impeller; Kinked or blocked tubing. | Clean pre-filter. Disconnect power and clear impeller. Check and clear tubing. |
| Pumpe ist laut. | Debris in impeller; Pump not fully submerged (if applicable); Air in system (if inline). | Clean impeller. Ensure pump is fully submerged. Bleed air from inline system. |
Garantie und Support
This Pondmaster Pond-Mag pump comes with a 5 Jahre eingeschränkte GarantieBitte bewahren Sie Ihren Kaufbeleg für Garantieansprüche auf.
For detailed warranty terms, technical support, or replacement parts, please refer to the official Danner Manufacturing, Inc. webWebsite oder wenden Sie sich an den Kundendienst.
Eine offizielle Bedienungsanleitung (PDF) steht ebenfalls zum Download bereit: Benutzerhandbuch herunterladen (PDF)
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.