Leviton 1222-2W

Leviton 1222-2W Double-Pole AC Quiet Switch Instruction Manual

Modell: 1222-2W

1. Produktüberschreitungview

The Leviton 1222-2W is a 20 Amp, 120/277 Volt, Toggle Double-Pole AC Quiet Switch designed for extra heavy-duty applications. This industrial-grade switch features a self-grounding design and supports both back and side wiring for flexible installation. It is built with high-quality materials to ensure durability and reliable performance.

Hauptmerkmale:

  • Industrial Quality: Constructed for demanding environments.
  • Heavy Gauge Copper Alloy Arm: Ensures top performance and longevity.
  • Large Silver Cadmium-Oxide Contacts: Designed for long life, preventing sticking, welding, and excessive pitting.
  • Fully Enclosed Switch Mechanism: Housed in a rugged enclosure for strength, track, and arc resistance.
  • Wire Lead Switches: Ermöglicht eine schnelle und einfache Installation.
Front view of the Leviton 1222-2W Double-Pole AC Quiet Switch

Abbildung 1: Vorderseite view of the Leviton 1222-2W Double-Pole AC Quiet Switch. Shows the white toggle and the metal mounting strap.

2. Sicherheitshinweise

WARNUNG: To avoid fire, shock, or death, turn off power at the circuit breaker or fuse box and test that the power is off before wiring! This device must be installed in accordance with all national and local electrical codes.

  • Always disconnect power at the service panel before working on any electrical circuit.
  • Verwenden Sie geeignete persönliche Schutzausrüstung (PSA) wie z. B. Schutzbrille und isolierende Handschuhe.
  • Wenn Sie sich über einen Teil dieser Anweisungen nicht sicher sind, wenden Sie sich an einen qualifizierten Elektriker.
  • Do not use this switch with loads exceeding its specified ratings (20 Amps, 120/277 Volts AC).
  • This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm (Proposition 65 warning). Wash hands after handling.

3. Spezifikationen

MarkeLeviton
Modellnummer1222-2 W
SchaltertypToggle, Double-Pole
Aktuelle Bewertung20 Amps
Bandtage Bewertung120/277 Volt Wechselstrom
BetriebsmodusEIN-AUS
Anzahl Positionen2
VerdrahtungstypBack and Side Wired
ErdungSelf Grounding
MaterialMetal (Mounting Strap), Silver Alloy (Contacts)
FarbeWeiß
ZertifizierungenCSA, FCC, RoHS, TUV, cUL

4. Einrichtung und Installation

Follow these steps carefully to install your Leviton 1222-2W Double-Pole AC Quiet Switch. Ensure all safety precautions are observed.

Erforderliche Werkzeuge:

  • Schraubendreher (Kreuzschlitz und Schlitz)
  • Abisolierzangen/-schneider
  • Bandtage-Tester
  • Isolierband (optional)

Installationsschritte:

  1. Strom ausschalten: Locate the circuit breaker or fuse that controls the power to the switch location. Turn it OFF. Use a voltage tester to confirm that the power is completely off at the switch box.
  2. Alten Schalter entfernen (falls zutreffend): Carefully remove the wall plate and unscrew the old switch from the electrical box. Disconnect the wires from the old switch, noting their positions.
  3. Drähte vorbereiten: If necessary, strip approximately 1/2 inch (12.7 mm) of insulation from the ends of the circuit wires. Ensure wire ends are clean and straight.
  4. Terminals identifizieren: The Leviton 1222-2W switch has four terminals for line and load connections, plus a green grounding screw. For a double-pole switch, there will be two 'LINE' terminals (for incoming power) and two 'LOAD' terminals (for outgoing power to the device). The switch is marked 'LINE' and 'LOAD' on the back.
  5. Zurück view of the Leviton 1222-2W Double-Pole AC Quiet Switch showing LINE and LOAD terminals

    Abbildung 2: Zurück view of the switch, indicating 'LINE' and 'LOAD' terminals for wiring connections. Note the green grounding screw at the bottom.

  6. Erdungskabel anschließen: Connect the bare copper or green insulated ground wire from the electrical box to the green grounding screw on the switch. Tighten securely.
  7. Connect Line Wires: Connect the two incoming hot (usually black) wires from the power source to the two 'LINE' terminals on the switch. You can use either the side screw terminals or the back-wire holes. Tighten screws firmly if using side terminals.
  8. Lastleitungen anschließen: Connect the two outgoing hot (usually black) wires leading to the fixture or appliance to the two 'LOAD' terminals on the switch. Tighten screws firmly.
  9. Seite view of the Leviton 1222-2W Double-Pole AC Quiet Switch with toggle in ON position

    Abbildung 3: Seitenansichtfile of the switch, showing the depth and the toggle in the 'ON' position. This view highlights the robust construction.

  10. Montieren Sie den Schalter: Carefully fold the wires into the electrical box, leaving enough room for the switch. Secure the switch to the electrical box using the provided mounting screws.
  11. Wandplatte installieren: Attach the wall plate over the switch.
  12. Strom wiederherstellen: Turn the power back ON at the circuit breaker or fuse box. Test the switch to ensure proper operation.

5. Bedienung

The Leviton 1222-2W is a simple ON-OFF toggle switch. To operate:

  • Zum Einschalten: Push the toggle lever to the 'ON' position (typically upwards).
  • Ausschalten: Push the toggle lever to the 'OFF' position (typically downwards).
Seite view of the Leviton 1222-2W Double-Pole AC Quiet Switch with toggle in OFF position

Abbildung 4: Seitenansichtfile of the switch, showing the depth and the toggle in the 'OFF' position. This view highlights the robust construction.

6. Wartung

The Leviton 1222-2W switch is designed for long-term, maintenance-free operation under normal conditions. However, periodic checks can help ensure continued safety and performance:

  • Reinigung: Um den Schalter und die Wandplatte zu reinigen, wischen Sie sie mit einem weichen, feuchten Tuch ab.amp Mit einem Tuch abwischen. Keine Scheuermittel oder Lösungsmittel verwenden. Vor der Reinigung sicherstellen, dass das Gerät ausgeschaltet ist.
  • Inspektion: Periodically inspect the switch and wall plate for any signs of damage, such as cracks, discoloration, or loose connections. If any damage is observed, turn off power and replace the switch.
  • Dichtheit: If the switch feels loose in the wall box, turn off power and gently tighten the mounting screws. Do not overtighten.

7. Fehlerbehebung

If you experience issues with your Leviton 1222-2W switch, refer to the following common problems and solutions:

ProblemMögliche UrsacheLösung
Switch does not turn ON/OFF power.Keine Stromversorgung des Stromkreises; Lose Kabelverbindung; Defekter Schalter.Check circuit breaker/fuse. Turn off power, check all wire connections for tightness. If connections are secure, replace the switch.
Der Schalter fühlt sich warm an.Overload on the circuit; Loose wiring connection; Internal fault.Immediately turn off power. Reduce load on the circuit. Check wiring connections for tightness. If problem persists, replace the switch.
Toggle is stiff or difficult to move.Dust or debris; Internal mechanism issue.Turn off power and gently clean around the toggle. If stiffness continues, replace the switch.

If troubleshooting steps do not resolve the issue, contact Leviton customer support or a qualified electrician.

8. Garantie und Support

Garantieinformationen:

This Leviton 1222-2W Double-Pole AC Quiet Switch is covered by a 10 Jahr eingeschränkte Garantie. This warranty covers defects in materials and workmanship under normal use and service. For full warranty details, please refer to the official Leviton warranty statement or contact customer support.

Kundendienst:

For technical assistance, product inquiries, or warranty claims, please contact Leviton customer support through their official website or the contact information provided with your purchase. When contacting support, please have your product model number (1222-2W) and purchase date available.

© 2026 Leviton Manufacturing Co., Inc. Alle Rechte vorbehalten.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.