1. Wichtige Sicherheitshinweise

Please read and understand all instructions before installing, operating, or performing maintenance on this pump. Failure to follow these instructions may result in electric shock, fire, serious injury, or property damage. Retain this manual for future reference.

  • Elektrische Sicherheit: Ensure power supply is disconnected before any installation or maintenance. All electrical wiring must be performed by a qualified electrician and comply with local codes and regulations.
  • Drucksicherheit: This pump operates under pressure. Ensure all connections are secure and leak-free before operation.
  • Temperatursicherheit: The pump handles fluids up to +130°C (266°F) and short-term up to +140°C (284°F). Exercise caution to avoid burns from hot surfaces or fluids.
  • Installation: This pump is designed for hydronic circulating applications. Do not use for purposes other than its intended use.

2. Produktüberschreitungview

The Wilo Top S 2 x 40 is a wet rotor hydronics circulating pump designed for residential and light commercial applications. It features a robust construction from stainless steel, polypropylene, and metal-impregnated carbon, ensuring durability and efficient performance. This model includes a two-speed motor for manual capacity adjustment.

Wilo Top S 2 x 40 Circulating Pump

Abbildung 1: Wilo Top S 2 x 40 Wet Rotor Hydronics Circulating Pump. This image displays the main unit of the circulating pump, highlighting its compact design and connection points.

Hauptmerkmale:

  • Wet rotor, seal-less design for quiet and maintenance-free operation.
  • Two pre-selectable speed stages for manual capacity adjustment.
  • Constructed from stainless steel, polypropylene, and metal-impregnated carbon for durability.
  • Cataphoretic coated pump housing for enhanced corrosion resistance.
  • Permitted temperature range: -20°C to +130°C (short-term to +140°C).
  • Pump communication based on simple plug technology for reliable retrofitting.

3. Installation und Einrichtung

Proper installation is crucial for the safe and efficient operation of your Wilo circulating pump. It is highly recommended that installation be performed by a qualified professional.

3.1 Prüfungen vor der Installation:

  • Überprüfen Sie, ob das Volumen der Pumpetage (115-Volt) matches your electrical supply.
  • Ensure the installation location is suitable, providing adequate space for maintenance and ventilation.
  • Confirm that the system piping is clean and free of debris.

3.2 Mechanical Installation:

  • The pump requires 4 Bolt 2-Inch HV flanges (not included) for connection to the piping system. Ensure these flanges are correctly sized and installed.
  • Install the pump in a horizontal position with the motor shaft horizontal to prevent air pockets and ensure proper lubrication.
  • Use appropriate gaskets and tighten flange bolts evenly to prevent leaks.
  • Support the pump and piping adequately to prevent strain on the connections.

3.3 Elektrischer Anschluss:

  • All electrical work must comply with national and local electrical codes.
  • Connect the pump to a dedicated, properly fused electrical circuit.
  • Stellen Sie sicher, dass die Pumpe ordnungsgemäß geerdet ist.
  • Die genauen Anschlussdetails entnehmen Sie bitte dem mit der Pumpe gelieferten Schaltplan.

4. Bedienungsanleitung

Once installed and electrically connected, the Wilo Top S 2 x 40 pump is ready for operation.

4.1 Erstinbetriebnahme:

  • Before starting, ensure the system is filled with fluid and properly vented to remove any air.
  • Open all necessary valves in the system.
  • Apply power to the pump. The pump should start circulating fluid.
  • Achten Sie auf ungewöhnliche Geräusche oder Vibrationen.

4.2 Geschwindigkeitseinstellung:

The Wilo Top S 2 x 40 features two pre-selectable speed stages. These can be adjusted manually to optimize flow rate and energy consumption for your specific hydronic system requirements. Consult your system design for the appropriate speed setting.

4.3 Normalbetrieb:

The pump is designed for continuous operation within its specified temperature range of -20°C to +130°C. Monitor the system for consistent performance and absence of leaks.

5. Wartung

The Wilo Top S 2 x 40 wet rotor design is largely maintenance-free. However, periodic checks are recommended to ensure optimal performance and longevity.

5.1 Regelmäßige Kontrollen:

  • Sichtprüfung: Periodically inspect the pump for any signs of leaks, corrosion, or damage to the housing or electrical connections.
  • Lärm und Vibration: Listen for any unusual noises or excessive vibrations, which could indicate a problem.
  • Systemdruck: Stellen Sie sicher, dass der Systemdruck innerhalb des empfohlenen Betriebsbereichs bleibt.

5.2 Reinigung:

Keep the exterior of the pump clean and free of dust and debris to ensure proper heat dissipation.

5.3 Winterfestmachung:

If the pump is installed in an unheated area subject to freezing temperatures, ensure the system is properly drained or protected with antifreeze to prevent damage.

6. Fehlerbehebung

This section provides solutions to common issues you might encounter with your Wilo circulating pump. For complex problems, contact a qualified technician.

ProblemMögliche UrsacheLösung
Pumpe startet nichtKeine Stromversorgung
Motor festgefahren
Falsche Verdrahtung
Prüfen Sie den Leitungsschutzschalter/die Sicherung.
Servicetechniker kontaktieren
Verify wiring with diagram
Niedrige DurchflussrateLuft im System
Partially closed valves
Clogged impeller/piping
Falsche Geschwindigkeitseinstellung
Belüftungssystem
Open all valves
Inspect and clean system
Geschwindigkeitseinstellung anpassen
Übermäßiger Lärm/VibrationenLuft im System
Lose Montage
Foreign object in pump
Vent system thoroughly
Befestigungsschrauben anziehen
Servicetechniker kontaktieren
Leckagen an den VerbindungenLoose flange bolts
Beschädigte Dichtung
Tighten bolts evenly
Dichtung ersetzen

7. Spezifikationen

Detailed technical specifications for the Wilo Top S 2 x 40 Circulating Pump, Model 2067579.

AttributWert
Modellnummer2067579
HerstellerWilo
Artikelgewicht45.8 Pfund
Verpackungsabmessungen18.9 x 16 x 13 Zoll
MaterialPolypropylen, Edelstahl
StromquelleWechselstrom/Gleichstrom
Bandtage115 Volt
Artikelpaket Menge1
Permitted Temperature Range-20°C to +130°C (short-term to +140°C)
Absperrkopf40 Fuß
Flange RequirementUses 4 Bolt 2-Inch HV flanges (not included)

8. Garantie und Support

8.1 Garantieinformationen:

Wilo Commercial Building Services products, including this circulating pump, come with a 2 Jahr eingeschränkte Garantie Diese Garantie gilt ab Kaufdatum und deckt Material- und Verarbeitungsfehler bei normalem Gebrauch und ordnungsgemäßer Wartung ab. Bitte bewahren Sie Ihren Kaufbeleg für Garantieansprüche auf.

8.2 Kundensupport:

For technical assistance, troubleshooting beyond this manual, or warranty inquiries, please contact Wilo customer service. Have your pump model number (2067579) and date of purchase ready when contacting support.

You can find contact information for Wilo customer service on their official webWebsite oder über Ihren lokalen Händler.

Ask a question about this manual