Murray MP1520

Murray MP1520 15-Amp und 20-Amp Single Pole 120V Circuit Breaker User Manual

1. Einleitung

This manual provides essential information for the safe installation, operation, and maintenance of the Murray MP1520 15-Amp und 20-Amp Single Pole 120V Circuit Breaker. Please read these instructions carefully before installation or use to ensure proper function and safety.

2. Sicherheitshinweise

WARNUNG: Gefahr von Stromschlag oder Brand.

  • Installation and servicing of electrical equipment should only be performed by qualified, licensed electricians.
  • Always disconnect power at the main service panel before working on circuit breakers or electrical panels.
  • Use only Murray brand circuit breakers in Murray load centers to maintain warranty and ensure compatibility.
  • Do not use "used" circuit breakers. The installation of used breakers in a Murray panel will void the warranty and may pose significant safety risks.
  • Stellen Sie sicher, dass alle Kabelverbindungen sicher sind und den örtlichen Elektrovorschriften entsprechen.

3. Produktüberschreitungview

The Murray MP1520 is a space-saving, plug-in duplex circuit breaker designed for use in Murray load centers and meter combinations that accept Type MH-T breakers. It combines one 15-Amp and one 20-Amp single-pole 120V circuit breaker into a single unit, occupying one standard panel space.

Murray MP1520 15-Amp und 20-Amp Single Pole 120V Circuit Breaker Front View

Figure 1: Murray MP1520 Circuit Breaker. This image shows the front view of the Murray MP1520 duplex circuit breaker, highlighting its compact design and visible ampAlterseinstufungen.

Murray MP1520 Circuit Breaker Side View mit Anschlusspunkten

Figure 2: Murray MP1520 Circuit Breaker. This image provides a side view of the Murray MP1520 circuit breaker, illustrating its plug-in mechanism and terminal connections.

This duplex breaker is ideal for adding new circuits when panel space is limited, providing two independent 1/2" breaker poles in a common unit. It is HACR rated. The internal configuration, as typically shown in technical diagrams for MH-T Duplex breakers, illustrates two independent 1/2" breaker poles, a line connection, and a load connection, all designed to fit within a single panel space.

4. Installation

  1. Kompatibilität überprüfen: Ensure your load center is rated to accept Type MH-T breakers. Refer to your load center's wiring diagram.
  2. Stromversorgung trennen: Schalten Sie die Hauptstromversorgung des Verteilerkastens am Stromzähler oder Haupttrennschalter ab. Überprüfen Sie mit einem Spannungsprüfer, ob der Strom tatsächlich abgeschaltet ist.tage Tester.
  3. Abdeckung entfernen: Entfernen Sie vorsichtig die Abdeckung des Schaltschranks.
  4. Steckplatz identifizieren: Locate an available 1-inch space on the panel's bus bar. The MP1520 requires one panel space.
  5. Sicherungsautomat installieren: Hook the rear of the breaker onto the retaining clip on the panel's bus bar. Press the front of the breaker firmly until it snaps into place on the bus bar.
  6. Verkabelung anschließen: Connect the circuit wires to the appropriate terminals on the breaker. The MP1520 has one 15-Amp and one 20-Amp pole. Ensure correct wire gauge for each amperage. Tighten terminal screws to the manufacturer's specified torque.
  7. Abdeckung ersetzen: Sobald alle Verbindungen sicher und überprüft sind, bringen Sie die Abdeckung des Verteilerkastens wieder an.
  8. Strom wiederherstellen: Schalten Sie die Hauptstromversorgung wieder ein.

Consult a qualified electrician if you are unsure about any step of the installation process.

5. Bedienung

The Murray MP1520 circuit breaker protects electrical circuits from overcurrents caused by overloads or short circuits. When an overcurrent condition occurs, the breaker will automatically "trip," interrupting the flow of electricity to the protected circuit.

  • EIN-Stellung: The breaker handle is fully pushed towards the "ON" position.
  • AUS-Position: The breaker handle is fully pushed towards the "OFF" position.
  • AUSGELÖST-Position: When tripped, the handle will move to an intermediate position, typically between "ON" and "OFF."

To reset a tripped breaker, first move the handle completely to the "OFF" position, then firmly push it to the "ON" position. If the breaker immediately trips again, there is likely a persistent fault in the circuit that needs to be addressed by a qualified electrician.

6. Wartung

Murray circuit breakers are designed for long-term, reliable operation with minimal maintenance. However, periodic inspection is recommended:

  • Sichtprüfung: Periodically inspect the circuit breaker and surrounding area for any signs of damage, discoloration, or loose connections.
  • Abstand halten: Ensure the electrical panel area remains clear of obstructions and debris to allow for proper ventilation and access.
  • Vermeiden Sie Tampering: Do not attempt to modify or repair the circuit breaker. Replace damaged breakers with new, genuine Murray products.

7. Fehlerbehebung

If your Murray MP1520 circuit breaker trips frequently, consider the following:

  • Überlasteter Stromkreis: The most common cause of tripping is an overloaded circuit. Disconnect some appliances or devices from the circuit and try resetting the breaker.
  • Kurzschluss: A short circuit can cause immediate tripping. This often indicates a wiring fault or a defective appliance. Unplug all devices from the circuit and try resetting. If it still trips, contact a qualified electrician.
  • Erdschluss: While the MP1520 is a standard breaker, ground faults can also cause tripping in some systems.
  • Defective Breaker: Although rare, a breaker can become faulty over time. If all other troubleshooting steps fail, the breaker may need replacement.

For persistent issues or if you are uncomfortable performing these checks, contact a qualified electrician.

8. Spezifikationen

BesonderheitDetail
MarkeMurray
ModellMP1520
Aktuelle Bewertung15 Amps (one pole), 20 Amps (one pole)
Bandtage120 Volt AC
Anzahl der Pole1 (Duplex, two independent 1/2" poles)
LeistungsschaltertypStandard, Plug-In Mount, MH-T Type
MontagetypSteckhalterung
AIC Rating10K AIC
Artikelgewicht5.76 Unzen
UPC040892521993

9. Garantie und Support

Murray (Siemens) strongly recommends against the use of "used" breakers. The installation of used breakers in a Murray (Siemens) panel will void the warranty on the panel. Murray (Siemens) does not sell used breakers and has not approved any 3rd party sellers to do so.

For technical support or warranty inquiries, please contact Murray customer service through their official website or authorized distributors. Always provide your model number (MP1520) when seeking assistance.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.