Pic Solution Classic Med Handbuch Blutdruckmessgerät – Benutzerhandbuch
Modell: SF1145240
Einführung
The Pic Solution Classic Med Manual Blood Pressure Monitor is designed to provide high-quality, accurate blood pressure measurements. Its large dial ensures easy reading of values, and the complete set of accessories makes it a reliable tool for personal health monitoring.
This manual provides essential information for the proper use, maintenance, and troubleshooting of your device. Please read it thoroughly before first use and keep it for future reference.

Image: The Pic Solution Classic Med Manual Blood Pressure Monitor, shown in its retail packaging, highlighting its design and key features.
Komponenten
Your Pic Solution Classic Med Manual Blood Pressure Monitor includes the following components:
- Manometer (Gauge): The circular dial that displays blood pressure readings.
- Manschette: A comfortable cuff with Velcro closure, designed to fit around the arm.
- Inflation Bulb: A rubber bulb used to inflate the cuff.
- Entlüftungsventil: A screw valve on the inflation bulb to control air release.
- Tragetasche: A practical zippered case for storage and transport.

Bild: Nahaufnahme view of the main components: the manometer (gauge), the arm cuff, and the inflation bulb with its air release valve.
Aufstellen
Before taking a measurement, ensure the device is properly assembled and you are in a suitable environment.
- Packen Sie das Gerät aus: Nehmen Sie alle Komponenten vorsichtig aus dem Transportkoffer.
- Verbinden Sie die Manschette: Stellen Sie sicher, dass der Luftschlauch der Manschette fest mit dem Manometer verbunden ist.
- Vorbereitung auf die Messung: Sit comfortably with your back supported and feet flat on the floor. Rest your arm on a table so that the cuff will be at heart level. Avoid talking or moving during the measurement.
- Manschette anlegen: Wrap the cuff firmly around your bare upper arm, approximately 2-3 cm above the elbow. The artery mark on the cuff should be positioned over your brachial artery (on the inside of your arm). Ensure it is snug but not too tight; you should be able to slide two fingers under the cuff.

Image: The Pic Solution Classic Med Manual Blood Pressure Monitor laid out next to its compact zippered carrying case, ready for setup or storage.
Bedienungsanleitung
Follow these steps to accurately measure your blood pressure using the auscultatory method (requires a stethoscope, not included):
- Locate Pulse: Place the diaphragm of a stethoscope over the brachial artery in the crook of your elbow.
- Ventil schließen: Turn the air release valve on the inflation bulb clockwise until it is fully closed.
- Manschette aufblasen: Rapidly pump the inflation bulb to inflate the cuff. Watch the manometer dial and inflate the cuff to about 20-30 mmHg above your usual systolic pressure, or until the pulse sound disappears.
- Release Air Slowly: Öffnen Sie das Entlüftungsventil langsam durch Drehen gegen den Uhrzeigersinn, sodass der Druck mit einer Geschwindigkeit von 2-3 mmHg pro Sekunde absinkt.
- Listen for Systolic Pressure: Listen carefully through the stethoscope. The first distinct, tapping sound you hear is your systolic blood pressure. Note the reading on the manometer.
- Listen for Diastolic Pressure: Continue to release air. The point at which the sounds disappear or become very faint is your diastolic blood pressure. Note this reading.
- Vollständig entleeren: Once the diastolic reading is taken, fully open the air release valve to rapidly deflate the cuff.
- Messwerte aufzeichnen: Record your systolic and diastolic blood pressure readings. Wait at least 5 minutes before taking another measurement.
Notiz: For accurate readings, it is recommended to consult with a healthcare professional for proper technique and interpretation of results.
Wartung und Pflege
Durch sachgemäße Wartung wird die Langlebigkeit und Genauigkeit Ihres Blutdruckmessgeräts sichergestellt.
- Reinigung: Reinigen Sie die Manschette mit einem weichen, fusselfreien Tuch.amp cloth and mild soap. Do not immerse the cuff or manometer in water. Wipe the manometer and inflation bulb with a dry or slightly damp Tuch.
- Lagerung: Store the device in its practical zippered carrying case in a cool, dry place, away from direct sunlight and extreme temperatures.
- Schäden vermeiden: Do not drop the manometer or subject it to strong impacts. Avoid bending the air tubes sharply.
- Kalibrierung: Manual blood pressure monitors should be calibrated periodically (e.g., every 1-2 years) by a qualified technician to ensure continued accuracy.

Image: The compact zippered carrying case for the Pic Solution Classic Med Manual Blood Pressure Monitor, designed for convenient storage and portability.
Fehlerbehebung
Sollten Sie Probleme mit Ihrem Blutdruckmessgerät haben, beachten Sie bitte die folgenden häufigen Probleme und Lösungen:
| Problem | Mögliche Ursache | Lösung |
|---|---|---|
| Die Manschette bläst sich nicht oder nur langsam auf. | Air release valve is open; loose connection; leak in cuff or tubing. | Ensure valve is fully closed. Check all connections. Inspect cuff and tubing for damage. |
| Die Messwerte sind uneinheitlich oder ungenau. | Improper cuff placement; rapid deflation; movement/talking during measurement; need for calibration. | Re-apply cuff correctly. Deflate at 2-3 mmHg/sec. Remain still and silent. Consider professional calibration. |
| Schwierigkeiten beim Hören der Korotkow-Laute. | Stethoscope placement; environmental noise; low inflation pressure. | Ensure stethoscope is correctly placed and functional. Measure in a quiet environment. Inflate cuff sufficiently. |
Wenn das Problem nach dem Ausprobieren dieser Lösungen weiterhin besteht, wenden Sie sich bitte an den Kundensupport.
Technische Daten
| Produktname | Pic Solution Classic Med Manual Blood Pressure Monitor |
| Modellnummer | SF1145240 |
| Marke | Bildlösung |
| Typ | Aneroid-Blutdruckmessgerät |
| Abmessungen (L x B x H) | 19 x 7.5 x 10.7 cm (ca. 7.5 x 3 x 4.2 Zoll) |
| Gewicht | 360 Gramm (ca. 0.79 Pfund) |
| Im Lieferumfang enthaltene Komponenten | Manometer, Cuff, Inflation Bulb, Carrying Case |
| Ursprungsland | Italien |
| ASIN | B008LVM70Q |
Garantie und Support
Pic Solution products are manufactured to high-quality standards. For information regarding warranty coverage, product support, or service, please refer to the warranty card included with your product or visit the official Pic Solution webWebsite.
For direct assistance, you may contact Pic Solution customer service through their official channels. Please have your model number (SF1145240) and purchase details ready when contacting support.
This manual is for informational purposes only and does not replace professional medical advice. Always consult with a healthcare professional for diagnosis and treatment of health conditions.