This manual provides instructions for the safe and effective use of your ExpertPower 7.2V 1500mAh NiCd replacement battery. Please read this manual thoroughly before using the battery to ensure optimal performance and safety.
These batteries are designed as direct replacements for various Makita 7.2V power tools.
Sicherheitshinweise
WARNING: Improper use of batteries can result in fire, explosion, or other hazards.
- Schließen Sie die Batteriepole nicht kurz.
- Setzen Sie die Batterie weder Wasser noch Feuchtigkeit aus.
- Do not store the battery in direct sunlight or high temperatures.
- Do not incinerate or dispose of the battery in fire.
- Versuchen Sie nicht, den Akku zu zerlegen oder zu modifizieren.
- Bewahren Sie Batterien außerhalb der Reichweite von Kindern auf.
- Use only chargers specifically designed for NiCd batteries.
- If the battery leaks, avoid contact with skin and eyes. Rinse immediately with water and seek medical attention.
Produkteigenschaften
- Brand New: Ensures fresh performance.
- Ni-Cd Chemistry: Nickel-Cadmium battery type.
- 7.2 Volts: Standardvolumentage for compatible tools.
- 1500 mAh Kapazität: Bietet ampLe-Power für längere Nutzung.
- Built-in Circuit Protection: Prevents overheating, short circuits, and overcharging.
- Hochwertige Materialien: Constructed for durability and reliability.
Kompatibilität
This ExpertPower battery is a replacement for Makita part numbers: 191679-9, 192532-2, 192695-4, 632002-4, 632003-2, 7000, 7002, 7033.
It is compatible with the following Makita power tool models:
- 3700D, 3700DW
- 4071D, 4073D
- 4307D, 4307DW
- 4770D
- 6002D, 6002DW, 6002DWK
- 6010D, 6010DL, 6010DW, 6010DWK
- 6012D, 6012DL, 6012DW, 6012DWK
- 6015DWE, 6015DWK
- 6016DW
- 6017DWBE, 6017DWE
- 6018D, 6018DWBE, 6018DWE
- 6019D, 6019DW, 6019DWBE, 6019DWE, 6019DWLE
- 6022DW
- 6071DW, 6071DWK
- 6072DL, 6072DW, 6072DWK
- 6073D, 6073DW
- 6075D, 6075DW
- 6172D, 6172DW
- 6710D, 6710DW
- 6912D, 6912DW
- 9035D, 9035DW
- 9200D
- 9500D, 9500DW
- DA3000D, DA3000DW
- DA301D, DA301DW
- DA302D, DA302DW, DA302DWB
- ML700 (Flashlight), ML701, ML702
- UH1070DW, UH3000D, UH3000DW, UH3070DW
- UM1000D, UM1200DW, UM1270DW
Setup und Installation
- Grundgebühr: For optimal performance, fully charge the battery before its first use. Refer to the "Charging" section for details.
- Einlegen der Batterie:
- Align the battery with the battery slot on your compatible Makita power tool.
- Slide the battery into the tool until it clicks securely into place. Ensure it is fully seated and does not wobble.
- Batterie entfernen:
- Locate the battery release button(s) on your power tool.
- Halten Sie die Entriegelungstaste(n) gedrückt, während Sie den Akku aus dem Werkzeug herausschieben.

Image: Two ExpertPower 7.2V NiCd batteries. These batteries are designed for compatibility with various Makita power tools.
Laden
Use only a charger specifically designed for 7.2V NiCd batteries. Using an incompatible charger can damage the battery or cause safety hazards.
- Connect your NiCd battery charger to a power outlet.
- Insert the ExpertPower battery into the charger, ensuring proper alignment.
- Observe the charger's indicator lights. A typical NiCd charger will show a red light during charging and a green light when fully charged. Refer to your charger's manual for specific indicator meanings.
- Allow the battery to charge completely. Overcharging NiCd batteries can reduce their lifespan, though built-in protection helps mitigate this.
- Sobald der Akku geladen ist, entnehmen Sie ihn aus dem Ladegerät.
Notiz: NiCd batteries can develop a "memory effect" if repeatedly recharged after only being partially discharged. To minimize this, it is recommended to fully discharge NiCd batteries before recharging them periodically.
Betrieb
Once the battery is fully charged and securely installed in your compatible Makita power tool, the tool is ready for operation according to its own user manual. Always follow the safety guidelines provided with your power tool.
- Ensure the battery is clean and free of debris before insertion.
- Drücken Sie den Akku nicht mit Gewalt in das Werkzeug oder das Ladegerät ein.
- Monitor battery performance during use. If the tool's power significantly decreases, it's time to recharge the battery.
Wartung
- Reinigung: Keep battery terminals clean and free of dirt or corrosion. Use a dry cloth to wipe them if necessary.
- Lagerung: Store batteries in a cool, dry place away from direct sunlight and extreme temperatures. For long-term storage, it is advisable to store NiCd batteries in a discharged state.
- Lebensdauer: NiCd batteries have a finite number of charge/discharge cycles. Proper charging and storage can help maximize their lifespan.
- Tiefentladung vermeiden: While NiCd batteries benefit from occasional full discharge to combat memory effect, consistently running them completely dead can stress the battery.
Fehlerbehebung
| Problem | Mögliche Ursache | Lösung |
|---|---|---|
| Akku wird nicht geladen |
|
|
| Kurze Laufzeit |
|
|
| Battery gets hot during charging/use |
|
|
Technische Daten
- Akku-Typ: NiCd (Nickel-Cadmium)
- Bandtage: 7.2 Volt
- Kapazität: 1500 mAh (Milliamp(vor Stunde)
- Modellnummer: I0IBTPMK7K15C
- Produktabmessungen: 1.94 x 1.11 x 5.3 Zoll
- Artikelgewicht: 1.4 pounds (Total weight for 2 batteries)
- Hersteller: ExpertenPower
Batterieentsorgung
NiCd batteries contain cadmium, a toxic heavy metal. Do not dispose of these batteries in household waste. Always dispose of NiCd batteries responsibly at designated recycling centers or according to local regulations. Many retailers that sell rechargeable batteries also offer recycling programs.
Proper disposal helps protect the environment and prevents potential health hazards.
Garantie und Support
For warranty information or technical support regarding your ExpertPower battery, please contact ExpertPower customer service directly. Refer to the packaging or the ExpertPower webDie Website enthält die aktuellen Kontaktdaten.
ExpertPower products are tested to match and/or exceed specifications of OEM products and are made with high-quality materials.