Einführung
Thank you for choosing the BN-LINK Digital Countdown Wall Timer Switch. This device is designed to provide convenient and energy-efficient control over your lights and exhaust fans. With its simple push-button operation and preset countdown options, you can easily automate shut-off times, helping to conserve energy and enhance your daily routine. This manual provides detailed instructions for installation, operation, and safety to ensure optimal performance and longevity of your timer switch.
Lieferumfang
- BN-LINK Digital Countdown Wall Timer Switch
- Wandplatte
- Drahtmuttern
- Befestigungsschrauben
- Bedienungsanleitung

Image: Package contents showing the timer switch, wire nuts, and wall plate.
Technische Daten
| Modell | BND-60/U110b-1 |
| Betriebsmodus | EIN-AUS |
| Aktuelle Bewertung | 15 Amps |
| Betriebslautstärketage | 125 Volt |
| Kontakttyp | Normalerweise geschlossen |
| Steckertyp | Clamp |
| Schaltertyp | Druckknopf |
| Terminal | Schrauben |
| Material | Plastik |
| Artikelabmessungen (L x B x H) | 4.2 x 1.8 x 2 Zoll |
| Schaltungsart | 1-Wege |
| Montagetyp | Wandhalterung |
| Antriebstyp | Druckknopf |
| Anzahl Positionen | 1 |
| Obere Temperaturbewertung | 122 Grad Fahrenheit |
| Kontrollmethode | Berühren |
| Wastage | 1875 Watt |
| Farbe | Weiß |
| Internationale Schutzbewertung | IP54 |
| Zertifizierung | ETL Listed (Conforms to UL Std. 60730-1, 60730-2-7) |

Image: Size details of the timer switch, including its dimensions and included accessories like wire nuts and face plate.
Wichtige Sicherheitsinformationen
- WARNUNG: Um Brände, Stromschläge oder Todesfälle zu vermeiden, schalten Sie die Stromzufuhr am Sicherungsautomaten oder Sicherungskasten ab und prüfen Sie vor Beginn der Verkabelung, ob der Strom tatsächlich abgeschaltet ist.
- Dieses Gerät benötigt ein Neutralleiter for proper operation. Ensure your electrical box has a neutral wire available.
- For single-pole installations only. Do not use in 3-way or multi-way switch applications.
- Ziehen Sie einen qualifizierten Elektriker zu Rate, wenn Sie sich bei irgendeinem Teil des Installationsprozesses unsicher sind.
- Rated 125V, 60 Hz, 15A/1875W Resistive or General Purpose, 10A/1250W Ballast or Tungsten, ½ HP, TV-5. Do not exceed these ratings.
Installationsanleitung
- Strom ausschalten: Before beginning any electrical work, ensure the power to the switch location is turned off at the circuit breaker or fuse box. Verify power is off using a voltage Tester.
- Vorhandenen Switch entfernen: Carefully remove the existing wall plate and switch from the electrical box. Disconnect the wires from the old switch, noting which wire was connected to which terminal.
- Drähte identifizieren: Identify the following wires in your electrical box:
- Heißer Draht (Leitung): Typischerweise schwarz, führt Strom vom Leistungsschalter.
- Lastkabel: Typically black, connects to the fan or light fixture.
- Neutralleiter: Üblicherweise weiß, erforderlich für diesen Zeitschalter.
- Erdungskabel: Typischerweise grünes oder blankes Kupfer.
- Den Zeitschalter anschließen: Connect the wires from your electrical box to the corresponding wires on the BN-LINK timer switch using the provided wire nuts.
- Verbinden Sie Heißer Draht from the wall to the Schwarzes Kabel des Timers.
- Verbinden Sie Draht laden von der Vorrichtung bis zur Rotes Kabel des Timers.
- Verbinden Sie Neutralleiter from the wall to the Weißer Draht des Timers.
- Verbinden Sie Erdungskabel from the wall to the Grüner Draht des Timers.
- Montieren Sie den Schalter: Carefully push the wired timer switch into the electrical box. Secure it with the provided mounting screws.
- Wandplatte installieren: Attach the included wall plate over the timer switch.
- Strom wiederherstellen: Schalten Sie den Strom am Leistungsschalter wieder ein.

Image: Detailed wiring diagram for the timer switch, emphasizing the neutral wire requirement.
Video: An instructional video demonstrating the installation and basic operation of the BN-LINK Countdown Digital In-wall Timer Switch.
Bedienungsanleitung
The BN-LINK Digital Countdown Wall Timer Switch features intuitive push-button controls for easy operation. Each button has a small LED indicator that illuminates when active.
1. Preset Countdown Functions
The timer offers six preset countdown durations: 5 minutes, 15 minutes, 30 minutes, 60 minutes (1 hour), 2 hours, and 4 hours. To activate a countdown:
- Press the button corresponding to your desired countdown time (e.g., "5 Min", "15 Min", "1 Hour").
- The LED indicator next to the selected button will illuminate, and the connected device (fan/light) will turn on.
- The device will automatically turn off once the countdown period expires.
2. Manual ON/OFF
The "ON/OFF" button allows for continuous operation or immediate shut-off, overriding any active countdown or repeat function.
- Press "ON/OFF" once to turn the connected device on indefinitely. The "ON/OFF" LED will illuminate.
- Press "ON/OFF" again to turn the connected device off immediately. The "ON/OFF" LED will turn off.
3. Wiederholfunktion
The "REPEAT" button activates a daily repeat for the currently selected countdown program.
- While a countdown program is active, press the "REPEAT" button. The "REPEAT" LED will illuminate.
- The selected countdown will automatically run at the same time every day.
- To deactivate the repeat function, press the "REPEAT" button again. The LED will turn off.
- Alternatively, pressing the "ON/OFF" button will also cancel the repeat function.

Bild: Überview of timer switch features, including LED indicators, one-button programming, repeat function, and manual ON/OFF.

Image: The repeat button on the timer switch, which allows for daily automatic countdowns.
Vielseitige Einsatzmöglichkeiten
This timer switch is suitable for a wide range of indoor applications, enhancing convenience and energy savings in various areas of your home. It is compatible with incandescent, fluorescent, and LED lighting, as well as bathroom exhaust fans and heaters.
- Badezimmer: Automatically turn off exhaust fans after a set period to manage humidity.
- Closets & Pantries: Ensure lights turn off after you leave.
- Garages & Basements: Prevent lights from being left on accidentally.
- Waschküchen: Control lighting or fan operation.
- Sauna Rooms: Set specific durations for sauna use.

Bild: Examples of various rooms and settings where the timer switch can be effectively utilized.
Fehlerbehebung
If you encounter any issues with your BN-LINK Digital Countdown Wall Timer Switch, please review the installation steps and operating instructions carefully. Ensure all wire connections are secure and that the power supply is active. If problems persist, please contact customer support for assistance.
Garantie und Kundendienst
The BN-LINK Digital Countdown Wall Timer Switch is ETL listed, conforming to UL Std. 60730-1 and 60730-2-7, ensuring safety and reliability. For any questions regarding installation, operation, or product support, please do not hesitate to contact BN-LINK customer service. We are committed to providing quality products and support to our customers.
Contact information can typically be found on the product packaging or the official BN-LINK webWebsite.
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.