1. Einleitung
This manual provides detailed instructions for the safe and correct installation, operation, and maintenance of your new ILIFE PX-B010 Li-ion Battery Power Pack. Please read this manual thoroughly before attempting to replace the battery in your ILIFE robotic vacuum cleaner. Proper installation ensures optimal performance and extends the lifespan of your device.
2. Sicherheitshinweise
Observe the following safety precautions to prevent damage to the battery, the vacuum cleaner, or personal injury:
- Das Batteriefach darf nicht auseinandergenommen, geöffnet oder zerkleinert werden.
- Setzen Sie den Akku weder Hitze noch Feuer aus. Vermeiden Sie die Lagerung in direktem Sonnenlicht.
- Der Akku darf nicht kurzgeschlossen werden. Akkus dürfen nicht achtlos in einer Kiste oder Schublade aufbewahrt werden, wo sie sich gegenseitig oder durch andere Metallgegenstände kurzschließen können.
- Nehmen Sie den Akkupack erst aus seiner Originalverpackung, wenn er verwendet werden soll.
- Setzen Sie Akkupacks keinen mechanischen Stößen aus.
- Sollte eine Batterie auslaufen, achten Sie darauf, dass die Flüssigkeit nicht mit Haut oder Augen in Berührung kommt. Falls es dennoch zu Kontakt gekommen ist, spülen Sie die betroffene Stelle gründlich mit Wasser ab und suchen Sie einen Arzt auf.
- Verwenden Sie ausschließlich das Ladegerät, das speziell für das Gerät vorgesehen ist.
- Dispose of the battery pack properly according to local regulations.
3. Produktüberschreitungview
The ILIFE PX-B010 is a high-quality Li-ion replacement battery designed to restore the cleaning performance of your compatible ILIFE robotic vacuum cleaner. It provides reliable power for extended cleaning sessions.

Image: The ILIFE PX-B010 Li-ion Battery Power Pack, showing its blue casing and connector wires.
3.1 Kompatibilität
This battery is compatible with the following ILIFE robotic vacuum cleaner models:
- ILIFE V3s Pro
- ILIFE V5s Pro
- ILIFE V8s
Notiz: Diese Batterie ist nicht compatible with ILIFE A9, A7, or A4s models.
3.2 Packungsinhalt
- 1 x ILIFE PX-B010 Li-ion Battery Power Pack
4. Installation
Follow these steps carefully to replace the battery in your ILIFE robotic vacuum cleaner. Ensure the vacuum is powered off and disconnected from its charging base before beginning.

Image: Visual guide illustrating the four steps of the battery replacement process for the ILIFE robotic vacuum cleaner.
4.1 Step-by-Step Replacement
- Disassemble the Battery Cover: Locate the screw on the battery cover at the bottom of your robotic vacuum. Use a screwdriver to loosen and remove the screw, then carefully lift off the battery cover.
- Trennen Sie die alte Batterie: Gently disconnect the wire connector of the old battery from the vacuum's port. Carefully remove the old battery from its compartment.
- Connect the New Battery: Take the new ILIFE PX-B010 battery. Connect its wire to the corresponding port inside the vacuum. Ensure the connection is secure. Aufmerksamkeit: The red wire of the vacuum should be connected with the red wire of the battery. Incorrect connection (e.g., black wire to red wire) can cause damage.
- Assemble the Battery Cover: Place the new battery into the compartment. Align the battery cover and secure it with the screw you removed in Step 1.
5. Bedienungsanleitung
After installing the new battery, follow these guidelines for optimal performance.
5.1 Erstaufladung
For the first use, place your robotic vacuum on its charging base and allow it to charge completely. A full charge typically takes several hours. Refer to your vacuum cleaner's original manual for specific charging indicators.
5.2 Normale Verwendung
Once fully charged, your robotic vacuum is ready for operation. The new battery should provide extended run times. Always return the vacuum to its charging base after each cleaning cycle to ensure it is ready for the next use.
6. Wartung
Proper maintenance of your battery can significantly extend its lifespan.
6.1 Batteriepflege
- Vermeiden Sie häufiges vollständiges Entladen des Akkus.
- Keep the vacuum and battery away from extreme temperatures (both hot and cold).
- Ensure the charging contacts on both the vacuum and the charging base are clean.
6.2 Speicherung
If you plan not to use your robotic vacuum for an extended period, fully charge the battery before storing it. Store the vacuum in a cool, dry place. It is recommended to charge the battery every 3-6 months to prevent deep discharge.
7. Fehlerbehebung
If you encounter issues after battery replacement, refer to the table below:
| Problem | Mögliche Ursache | Lösung |
|---|---|---|
| Vacuum does not power on after battery replacement. | Battery not connected properly or not charged. | Check battery connection (ensure red wire to red wire). Place vacuum on charging base for initial charge. |
| Kurze Laufzeit nach dem Aufladen. | Battery not fully charged or incorrect charging procedure. | Ensure vacuum is charging correctly. Allow for a full charge cycle. If issue persists, contact support. |
| Vacuum beeps continuously. | Indicates a battery or charging error. | Verify battery connection. Clean charging contacts. Refer to your vacuum's original manual for specific error codes. |
8. Spezifikationen
Technical specifications for the ILIFE PX-B010 Li-ion Battery Power Pack:
| Besonderheit | Spezifikation |
|---|---|
| Akku-Typ | Li-ion |
| Bandtage | 14.4 V |
| Kapazität | 2600 mAh |
| Modellnummer | ILIFEBP03 / PX-B010 |
| Gewicht | 190 Gramm |
9. Garantie und Support
ILIFE provides customer support for its products. For warranty information, please refer to the documentation included with your original robotic vacuum cleaner or contact ILIFE customer service directly.
9.1-Kontaktinformationen
- US-Kundendienst: 1-800-631-9676 (Mon-Fri: 9:00 AM - 5:00 PM CST)
- US Email Support: support@ililiferobot.com
- Offiziell WebWebsite: www.ililiferobot.com
- Andere Regionen: Bitte beachten Sie die Produktverpackung oder die offiziellen Angaben. webWebsite für regionale Kontaktdaten.