CEM DT-172

CEM DT-172 Temperature and Humidity Data Logger User Manual

Modell: DT-172

1. Einleitung

The CEM DT-172 is a temperature and humidity data logger designed for efficient and convenient long-term environmental monitoring. This device records temperature and humidity values, storing them internally for later retrieval and analysis via a personal computer with a USB interface. This manual provides essential information for the proper setup, operation, and maintenance of your DT-172 data logger.

2. Sicherheitshinweise

Bitte lesen und verstehen Sie die folgenden Sicherheitsvorkehrungen, bevor Sie das Gerät benutzen:

  • Lesen Sie alle Anweisungen sorgfältig durch, bevor Sie das Gerät in Betrieb nehmen.
  • Do not expose the device to extreme temperatures or humidity levels outside its specified operating range.
  • Do not attempt to open, disassemble, or modify the device. This may void the warranty and cause damage.
  • Dispose of depleted batteries according to local environmental regulations.
  • Halten Sie das Gerät von starken elektromagnetischen Feldern fern.

3. Produktüberschreitungview

The CEM DT-172 features a compact design with an LCD display and two control buttons. It is equipped with internal sensors for accurate temperature and humidity measurement.

3.1 Hauptmerkmale

  • Memory capacity for 32,000 readings (16,000 each for temperature and humidity).
  • LCD display provides real-time data and logging status.
  • User-selectable measurement cycle from 1 second to 24 hours.
  • Extended battery life, typically more than 3 years.
  • USB interface for convenient data download to a PC.
  • Alarm display indicates when user-defined maximum or minimum values are exceeded.
  • Includes analysis software for data graphing, review, and export.
  • Supports temperature measurement in both Celsius (°C) and Fahrenheit (°F).
  • High resolution: 0.1°C and 0.1% RH.

3.2 Komponenten

Das Standardpaket beinhaltet:

  • DT-172 Data Logger Unit
  • Bedienungsanleitung
  • 3.6V Lithium battery (14250 type) (Note: Batteries are not included in some packages and must be purchased separately)
  • Software-CD
  • USB-Kabel
  • Wandhalterung
  • Instrument Lock
CEM DT-172 Data Logger with highlighted features: Wide Range, Relative Humidity, Resolution, LED, USB, 16000 Data Memory.

Figure 1: CEM DT-172 Data Logger highlighting key features and display.

CEM DT-172 Data Logger with included accessories: USB cable, 3.6V Lithium battery, and instrument lock.

Figure 2: CEM DT-172 Data Logger with its accessories.

4. Einrichtung

4.1 Einlegen der Batterie

  1. Locate the battery compartment on the back of the DT-172 device.
  2. Öffnen Sie die Abdeckung des Batteriefachs.
  3. Insert one 3.6V Lithium battery (14250 type) into the compartment, ensuring correct polarity.
  4. Schließen Sie den Batteriefachdeckel sicher.

Notiz: Batterien sind in der Regel nicht im Lieferumfang enthalten und müssen separat erworben werden.

4.2 Softwareinstallation

  1. Insert the provided Software CD into your computer's CD-ROM drive.
  2. Follow the on-screen instructions to install the analysis software. The software is compatible with Windows 98/2000/XP/Vista/7 operating systems.

4.3 Initial Connection to PC

  1. Connect the data logger to your computer using the supplied USB cable.
  2. Your computer should automatically detect the device and install any necessary drivers.
Hand holding CEM DT-172 Data Logger connected to a laptop via USB cable.

Figure 3: Connecting the DT-172 Data Logger to a PC via USB.

5. Bedienungsanleitung

5.1 Ein-/Ausschalten

The device typically powers on automatically upon correct battery installation. There is no explicit power button.

5.2 Informationen anzeigen

The LCD displays current temperature, humidity, time, and logging status. Two LEDs, labeled ALM (Alarm) and AUFNAHME (Recording), indicate the device's status.

Nahaufnahme view of the CEM DT-172 Data Logger's LCD display showing temperature, time, and buttons.

Figure 4: Close-up of the DT-172 display and control buttons.

5.3 Tastenfunktionen

  • Temp. %RH Button: Press this button to cycle between displaying the current temperature and relative humidity readings on the LCD.
  • MAX/MIN-Taste: Drücken Sie diese Taste, um view the maximum and minimum recorded temperature and humidity values since the last reset or logging session.

5.4 Starten der Datenprotokollierung

  1. Connect the data logger to your PC and open the analysis software.
  2. Use the software to configure desired logging parameters, such as the measurement cycle (e.g., 1 second, 1 hour, 24 hours) and any alarm limits for temperature and humidity.
  3. Once configured, disconnect the logger from the PC. The device will automatically begin standalone data logging. The AUFNAHME LED will illuminate to indicate active recording.

5.5 Herunterladen von Daten

  1. To retrieve recorded data, connect the data logger to your PC via the USB cable.
  2. Open the analysis software on your computer.
  3. Follow the software's instructions to download the logged data from the device.
  4. Die Software ermöglicht Ihnen Folgendes: view the data in graphical format, analyze trends, and export the data for further processing.

6. Wartung

6.1 Batteriewechsel

When the battery indicator on the LCD shows low power, replace the 3.6V Lithium battery (14250 type) promptly to ensure continuous operation and prevent data loss. Refer to Section 4.1 for battery installation steps.

6.2 Reinigung

Wipe the device with a soft, dry cloth. Do not use abrasive cleaners, solvents, or immerse the device in water. Ensure the sensor area remains clean and free of dust or obstructions for accurate readings.

7. Fehlerbehebung

  • Gerät lässt sich nicht einschalten: Check if the 3.6V Lithium battery (14250) is correctly installed and not depleted. Ensure proper polarity.
  • No data logging: Verify that logging parameters have been set and activated via the analysis software. Confirm the AUFNAHME LED is illuminated when the device is disconnected from the PC. Ensure sufficient memory is available (32,000 readings capacity).
  • Cannot connect to PC or download data: Ensure the USB cable is securely connected to both the logger and the PC. Verify that the analysis software is correctly installed. Try connecting to a different USB port on your computer.
  • Alarm indication (ALM LED): Der ALM LED indicates that user-defined maximum or minimum temperature/humidity values have been exceeded. Review your logged data using the software to identify the specific exceedance.
  • Inaccurate RH readings at low humidity: Some users have reported limitations in logging data for relative humidity below 18% RH. This may be a characteristic of the device's sensor.

8. Spezifikationen

ParameterWert
Temperaturbereich-40 bis 70 °C (-40 bis 158 °F)
Temperaturgenauigkeit±1 °C
Feuchtigkeitsbereich0 bis 100 % relative Luftfeuchtigkeit
Feuchtigkeitsgenauigkeit±3.5% relative Luftfeuchtigkeit
Speicherkapazität32,000 readings (16,000 for Temp, 16,000 for RH)
Messrate1 second to 24 hours (selectable)
Auflösung0.1 °C, 0.1 % relative Luftfeuchtigkeit
AkkulaufzeitNormalerweise 3 Jahre
Stromquelle1 x 3.6V Lithium battery (14250)
Analyse-SoftwareWindows 98/2000/XP/Vista/7 compatible
Abmessungen (HxBxT)94 mm x 50 mm x 32 mm (ca. 9.4 cm x 5 cm x 3.2 cm)
Gewicht91g
MontagetypWandhalterung
ModellnummerDT-172
UPC736631254849
CEM DT-172 Data Logger with dimensions indicated as 5cm width and 9.4cm height.

Figure 5: DT-172 Data Logger with approximate dimensions.

9. Garantieinformationen

Warranty details for the CEM DT-172 Temperature and Humidity Data Logger are not specified in the provided product information. Please refer to your purchase documentation or contact the manufacturer directly for specific warranty terms and conditions.

10. Kundendienst

For technical assistance, inquiries, or support regarding your CEM DT-172 Data Logger, please contact CEM Instruments (India) Pvt. Ltd. using the information below:

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.