Akozon OP320-A

Akozon OP320-A HMI Text Display User Manual

Model: OP320-A

1. Einleitung

1.1 Produktüberschussview

The Akozon OP320-A HMI Text Display is a compact human-machine interface designed for interaction with various Programmable Logic Controllers (PLCs) or intelligent controllers equipped with communication ports. It enables users to monitor and modify internal register values and relay statuses of a PLC through text-based displays or indicators, facilitating control over automated equipment.

1.2 Hauptmerkmale

  • Anzeige: 3.7-inch monochrome LCD screen with 192 x 64 pixel resolution and 60cd/m2 brightness.
  • Prozessor: 8-bit processor for efficient operation.
  • Erinnerung: 64 KB Flash ROM.
  • Eingang: Keyboard input with 20 user-definable function buttons.
  • Kommunikation: Supports COM1: PC RS232 and PLC S485/RS232 communication protocols.
  • Haltbarkeit: Constructed from ABS material with imported chips for shock resistance and stable performance.
  • Sicherheit: Features password protection and an alarm list function for real-time display of current alarm information.
  • Konfiguration: Allows direct input of characters and PLC addresses. Screen data can be downloaded via serial communication using the TP200CN editing software.

2. Einrichtung

2.1 Packungsinhalt

Überprüfen Sie, ob alle Artikel im Paket vorhanden sind:

  • 1 x Akozon OP320-A Text Display
  • 1 set x Installation Accessories

2.2 Physische Installation

The display is designed for panel mounting. Refer to the dimensions below for proper cutout and installation.

Akozon OP320-A HMI Text Display with dimensions labeled

Figure 2.2.1: OP320-A HMI Text Display with dimensions. The device measures 172mm (6.8in) in length, 94mm (3.7in) in width, and 30mm (1.2in) in depth. The mounting hole size required is 165mm x 86mm.

Größe des Montagelochs: 165 mm x 86 mm (6.5 Zoll x 3.4 Zoll)

Use the provided installation accessories to secure the display firmly into the panel cutout.

2.3 Elektrischer Anschluss

Connect the display to a stable power source within the specified voltage Reichweite.

  • Stromversorgung: 12~24V (V) ±10%
  • Stromverbrauch: <150 mA

Ensure correct polarity when connecting the power supply to prevent damage to the device.

2.4 Verbindung über Kommunikationsanschluss

The OP320-A supports RS232 and RS485 communication protocols for connecting to a PC or PLC.

Hinteren view of Akozon OP320-A HMI Text Display showing communication ports

Abbildung 2.4.1: Rückseite view of the OP320-A HMI Text Display. This image highlights the DB9 RS232 serial port and the green terminal block for RS485/power connections.

  • COM1: PC RS232, PLC S485/RS232

Use appropriate cables for connecting to your PC or PLC. Refer to your PLC's documentation for specific wiring diagrams for RS232 or RS485 communication.

3. Bedienung

3.1 Grundfunktionen

The OP320-A allows operators to monitor and modify PLC data. The display shows text or indicators representing PLC internal registers or relay statuses.

Front view of Akozon OP320-A HMI Text Display with 'Welcome to JingBiao Automation' on screen

Abbildung 3.1.1: Vorderseite view of the OP320-A HMI Text Display. The screen displays 'Welcome to JingBiao Automation'. The keypad includes numeric buttons (0-9), +/-/CLR, ESC, ALM, arrow keys, SET, and ENT buttons.

3.2 Keyboard Input

The display features a numeric keypad and function buttons for data entry and navigation.

  • Ziffernblock (0-9): For entering numerical values.
  • +/-/CLR: Used for sign changes or clearing input.
  • ESC: Escape or cancel function.
  • ALM: Access alarm information.
  • Arrow Keys (Up, Down, Left, Right): For navigation within menus or data fields.
  • EINSTELLEN: Enter setup or configuration modes.
  • HNO: Confirm or enter selection.

The 20 self-defined function buttons can be programmed for specific tasks within your application.

3.3 Softwarekonfiguration

The OP320-A is configured using the TP200CN editing software on a computer. This software allows you to:

  • Create and edit display screens.
  • Define PLC addresses for monitoring and control.
  • Download screen data and communication protocols to the display via serial communication.

No PLC communication program is required for the display to function once configured.

3.4 Alarmfunktion

The display includes an alarm list function. When an alarm condition is met in the PLC, the display can show real-time alarm information by line. Access to certain functions or configurations may be protected by a password.

4. Wartung

4.1 Reinigung

To clean the display, use a soft, dry cloth. For stubborn dirt, a slightly damp cloth with a mild, non-abrasive cleaner can be used. Avoid using harsh chemicals, solvents, or abrasive materials, as these can damage the screen or casing.

4.2 Umgebungsbedingungen

Ensure the display operates within the specified environmental conditions to maintain optimal performance and longevity.

  • Arbeitstemperatur: 0 ~ 50 ℃ (32 ~ 122 ℉)
  • Luftfeuchtigkeit in der Arbeitsumgebung: 20 – 90 % relative Luftfeuchtigkeit (nicht kondensierend)
  • Lagertemperatur: -20 ~ 70 ℃ (-4 ~ 158 ℉)

The device has an IP65 grade, indicating protection against dust and low-pressure water jets from any direction. However, avoid prolonged exposure to extreme conditions.

5. Fehlerbehebung

5.1 Häufige Probleme

  • Bildschirm schaltet sich nicht ein:
    • Check the power supply connection and ensure it is within the 12-24V range.
    • Vergewissern Sie sich, dass die Stromquelle aktiv ist.
  • Keine Kommunikation mit der SPS:
    • Ensure the communication cable is correctly connected to both the HMI and the PLC.
    • Verify that the communication settings (baud rate, data bits, parity, stop bits) in the HMI and PLC match.
    • Check the wiring for RS232 or RS485 for proper pin assignments.
    • Confirm that the PLC is powered on and functioning correctly.
  • Falsche Daten angezeigt:
    • Review the PLC address settings in the HMI configuration software (TP200CN) to ensure they correspond to the actual PLC registers.
    • Verify the data format and scaling settings.
  • Bildschirm reagiert nicht:
    • Restart the HMI by cycling its power.
    • If the issue persists, re-download the HMI configuration using TP200CN.

6. Technische Daten

ParameterSpezifikation
ModellOP320-A
Anzeigegröße3.7 Zoll
AnzeigetypMonochrome LCD (STN LCD with backlight)
Auflösung192 x 64 pixels (24 English characters x 4 lines / 12 Chinese characters x 4 lines)
Helligkeit60 cd/m2
Prozessor8-Bit-Prozessor
Erinnerung64 KB Flash ROM
EingabemethodeKeyboard input (20 self-defined function buttons)
KommunikationsanschlussCOM1: PC RS232, PLC S485/RS232
Stromversorgung12~24V ±10%
Stromverbrauch<150 mA
Power Off Allowed20 ms
Anti-interference TestBandtage 1500v, p-p pulse cycle 1us, continuous 1S
Drucktest500vAC 1 min
Isolationswiderstand>10 MΩ
Shockproof Test10~25 Hz
SchutzgradIP65
Arbeitstemperatur0 ~ 50 ℃
Arbeitsfeuchtigkeit20 ~ 90% relative Luftfeuchtigkeit
Lagertemperatur-20 ~ 70 ℃
SchalenmaterialTechnische Kunststoffe
Anzeigebereichsgröße101 x 36 (4 x 1.4)
Größe des Montagelochs165 x 86 (6.5 x 3.4)
Gesamtgröße172 x 94 x 30 mm (6.8 x 3.7 x 1.2 Zoll)
GewichtCa. 338 g

7. Garantieinformationen

This product is covered by the manufacturer's standard warranty. Please refer to the warranty documentation provided with your purchase for details regarding coverage, terms, and conditions. Keep your proof of purchase for any warranty claims.

8. Unterstützung

For technical assistance, troubleshooting, or further inquiries regarding the Akozon OP320-A HMI Text Display, please contact your vendor or refer to the official Akozon support channels. You may also visit the Akozon Store on Amazon für zusätzliche Produktinformationen.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.