Walfront GRT8-M1

Walfront GRT8-M1 Multifunctional Delay Time Relay

Bedienungsanleitung

1. Einleitung

The Walfront GRT8-M1 is a versatile multifunctional delay time relay designed for various industrial and home automation applications. It offers 10 distinct delay functions and a wide time delay setting range from 0.1 seconds to 10 days. This relay is suitable for controlling electrical appliances, lighting, heating systems, motors, pumps, and fans. Its compact design allows for easy DIN rail mounting.

Hauptmerkmale:

  • Ultra-wide delay range: 0.1s - 10 days.
  • 10 delay functions including delay on, delay off, and cycle delay.
  • LED indicators for relay working status.
  • Compact 35mm DIN rail mounting.
  • Mehrbändtage compatibility: AC/DC 12V~240V.

2. Sicherheitshinweise

WARNUNG: Stromschlaggefahr. Installation und Wartung dürfen nur von qualifizierten Elektrikern gemäß allen lokalen und nationalen Elektrovorschriften durchgeführt werden.

  • Vor der Installation oder Wartung muss die Stromzufuhr unterbrochen werden.
  • Überprüfen Sie die korrekte Voltage and current ratings for your application.
  • Do not exceed the maximum switching voltage oder aktuell.
  • The product is designed for indoor use in a dry environment.
  • Der gesamte Elektroschrott sollte gemäß den geltenden WEEE-Vorschriften entsorgt werden.

3. Produktüberschreitungview

The GRT8-M1 delay time relay features a compact housing with clearly labeled terminals and control knobs. It includes LED indicators for power and relay status.

Walfront GRT8-M1 Delay Time Relay with dimensions

Bild 3.1: Front view of the GRT8-M1 Delay Time Relay showing its dimensions (90mm/3.5in length, 64mm/2.5in height, 18mm/0.7in width) and terminal labels (A1, A2, 15, 16, 18). It also highlights the red relay status indicator and green power indicator.

Walfront GRT8-M1 Delay Time Relay with knob time adjustment diagram

Bild 3.2: Nahaufnahme view of the GRT8-M1 relay showing the two rotary knobs for time adjustment and function selection, along with the LED indicators. The diagram illustrates how to set the time range (Knob 1) and percentage (Knob 2).

Video 3.1: This video demonstrates the unboxing and physical handling of the Walfront GRT8-M1 Delay Time Relay, showcasing its compact size and DIN rail mounting mechanism. It provides a visual overview of the product's exterior and components.

4. Spezifikationen

ParameterWert
MarkeWalfront
ModellGRT8-M1
VersorgungsklemmenA1 bis A2
Bandtage ReichweiteAC/DC 12V~240V (50/60Hz)
LeistungsaufnahmeAC max 6VA/1.7W
Versorgungsvolumentage Toleranz-15 %; +10 %
Zeiteinstellung0.1s - 10 days (ON/OFF potentiometer)
Wiederholgenauigkeit0.2% set value stability
Temperaturkoeffizient0.05%/°C, at 20°C (68°F)
Ausgabe1 SPDT
Aktuelle Bewertung16A AC1
Schaltlautstärketage250 V Wechselstrom/24 V Gleichstrom
Mindestausschaltvermögen (Gleichstrom)500 mW
AusgangsanzeigeRote LED
Mechanische Lebensdauer1 x 107
Elektrische Lebensdauer (AC1)1 x 105
Montage35-mm-DIN-Schiene
Gewicht0.08 kg
Betriebstemperatur-20°C bis +55°C (-4°F bis 131°F)
Lagertemperatur-35°C bis +75°C (-31°F bis 167°F)

5. Installation

5.1 DIN-Schienenmontage

The GRT8-M1 is designed for easy mounting on a standard 35mm DIN rail. Simply align the relay with the rail and press firmly until it clicks into place. To remove, pull the red tabs at the bottom of the unit and lift it off the rail.

Walfront GRT8-M1 Delay Time Relay mounted on a DIN rail

Bild 5.1: The GRT8-M1 Delay Time Relay shown mounted on a standard DIN rail, illustrating its compact form factor and secure attachment method.

5.2 Schaltplan

Connect the relay according to the appropriate wiring diagram for your desired function. Ensure all connections are secure and correctly terminated. The terminals are labeled A1, A2 for power input, and 15, 16, 18 for the output contact (15: Common, 16: Normally Closed, 18: Normally Open).

Panel Diagram and Wiring Diagram for GRT8-M1

Bild 5.2: This image displays the panel diagram of the GRT8-M1, indicating the supply (green) and output (red) indicators, time setting, and function setting knobs. Below it, various wiring diagrams are shown for different contact configurations (1 SPDT).

Detailed wiring diagram for Walfront GRT8-M1

Bild 5.3: A detailed wiring diagram showing the connection points for the GRT8-M1 relay, including the trigger terminal (S), working power input (A1, A2), and output contacts (15, 16, 18). It also illustrates a typical application with a load connected.

6. Bedienung

The GRT8-M1 features two rotary knobs for setting the time range and the percentage of that range, along with a function selection knob.

6.1 Zeiteinstellung

The time delay is set using two knobs:

  • Knopf 1 (oben): Selects the time gear (e.g., 1s, 10s, 1m, 10m, 1h, 10h, 1d, 10d). 'ON' for relay operation (15-18 closed), 'OFF' for relay open (15-16 closed).
  • Knopf 2 (unten): Fine adjustment of the delay time, from 10% to 100% of the selected time gear.

ExampTeil 1: To set a 5-second delay:

  1. Set Knob 1 to '10s'.
  2. Set Knob 2 to '50%'.
  3. Calculated delay time = 10s * 50% = 5s.

ExampTeil 2: To set an 8-minute delay:

  1. Set Knob 1 to '10m'.
  2. Set Knob 2 to '80%'.
  3. Calculated delay time = 10m * 80% = 8m.
Dimensions and Setting Instructions for GRT8-M1

Bild 6.1: This image provides a diagram of the GRT8-M1's dimensions and detailed instructions for setting the delay time using the two rotary knobs. It includes examples for calculating the final delay time.

6.2 Funktionsauswahl

The GRT8-M1 offers 10 functions, selected via a rotary switch. Each function has a specific timing diagram:

Functions Diagram for GRT8-M1 Delay Time Relay

Bild 6.2: A comprehensive diagram illustrating the 10 different operating functions (A-J) of the GRT8-M1 relay. Each function is accompanied by a timing chart showing the relationship between input voltage (Un), trigger signal (S), and relay contact status (R) over time.

  • A: On Delay (Power On): Delay starts when input voltage U is applied. Contacts R transfer after delay t.
  • B: Interval (Power On): Delay starts when input voltage U is applied. Contacts R transfer immediately and return after delay t.
  • C: Repeat Cycle (Starting Off): Delay starts when input voltage U is applied. Contacts R transfer after delay t1, then return after t2. Cycle repeats until U is removed.
  • D: Repeat Cycle (Starting On): Delay starts when input voltage U is applied. Contacts R transfer immediately for t1, then return for t2. Cycle repeats until U is removed.
  • E: Off Delay (S Break): Eingangsvolumentage U must be applied continuously. When trigger switch S is closed, relay contacts R change state. When trigger switch S is opened, delay t begins. When delay t is complete, contacts R return to their shelf state.
  • F: Single Shot: Bei Anwendung von Input voltage U, das Relais ist bereit, das Auslösesignal S anzunehmen. Bei Anlegen des Auslösesignals S wechseln die Relaiskontakte R und die voreingestellte Zeit t beginnt. Während des Timeouts wird das Triggersignal S ignoriert. Das Relais wird durch Betätigen des Auslöseschalters S zurückgesetzt, wenn das Relais nicht erregt ist.
  • G: Single Shot Trailing Edge (Non-Retriggerable): Bei Anwendung von Input voltage U, the relay is ready to accept trigger signal S. Upon application of the trigger signal S, the relay contacts R transfer and the preset time t begins. If the trigger switch S is opened and closed prior to time out t (before preset time elapses). Continuous cycling of the trigger switch S at a rate faster than the preset time t will cause the relay contacts R to remain closed. If input voltage U wird entfernt, die Relaiskontakte R kehren in ihren Ruhezustand zurück.
  • H: On/Off Delay: Eingangsvolumentage U muss kontinuierlich angewendet werden. Beim Schließen des Auslöseschalters S beginnt die Zeitverzögerung t. Wenn die Zeitverzögerung t abgelaufen ist, ändern die Relaiskontakte R ihren Zustand und bleiben im Zustand, bis der Auslöseschalter S geöffnet wird. Wenn Eingabevoltage U wird entfernt, die Relaiskontakte R kehren in ihren Ruhezustand zurück.
  • I: Latching Relay: Eingangsvolumentage U muss kontinuierlich angewendet werden. Der Ausgang ändert seinen Zustand bei jedem Schließen des Auslöseschalters S. Wenn Eingabevoltage U wird entfernt, die Relaiskontakte R kehren in ihren Ruhezustand zurück.
  • J: Pulse Generator: Bei Anwendung von Input voltage U, a single output pulse of 0.5 seconds is delivered to relay after time delay t. Power must be removed and re-applied to repeat pulse. Trigger switch S is not used in this function.

7. Wartung

The Walfront GRT8-M1 delay time relay requires minimal maintenance. Keep the unit clean and free from dust and moisture. Periodically check terminal connections for tightness to ensure reliable operation. Do not attempt to open or repair the unit yourself; refer to qualified personnel for any issues beyond basic troubleshooting.

8. Fehlerbehebung

  • Relay not powering on: Eingangslautstärke prüfentage (A1-A2) and ensure it is within the AC/DC 12V~240V range. Verify power connections.
  • Relais schaltet nicht: Confirm the selected function and time settings are correct. Check trigger signal (S) if applicable. Ensure the load is properly connected to terminals 15, 16, 18.
  • Falscher Zeitpunkt: Re-check Knob 1 (time gear) and Knob 2 (percentage) settings. Ensure the selected time range matches your requirement.
  • LED-Anzeigen funktionieren nicht: If the green power LED is off, check power supply. If the red relay status LED is off when it should be on, check load and wiring.

If issues persist, consult a qualified electrician or contact customer support.