Walfront AS1392

Walfront SMART Sensor AS1392 EMF Meter User Manual

Modell: AS1392

Einführung

This user manual provides detailed instructions for the operation and maintenance of the Walfront SMART Sensor AS1392 EMF Meter. This device is designed to detect electromagnetic fields (EMF) and measure ambient temperature, offering a reliable tool for environmental monitoring. Please read this manual thoroughly before using the device to ensure safe and correct operation.

Produkt überview

Hauptmerkmale

  • Doppelte Messung: Capable of testing both electric and magnetic field radiation.
  • Temperatur messung: Measures environmental temperature in both Celsius (°C) and Fahrenheit (°F).
  • Alarmfunktion: Features sound and light alarms that activate when detected radiation levels exceed a preset safe value.
  • Klare Anzeige: Equipped with a large, high-definition LCD screen for easy reading of measurements.
  • Datenaufbewahrung: Includes a one-button function to lock the current radiation value for review.
  • Portabilität: Designed for simple, one-handed operation and easy on-site measurement.

Komponentenidentifikation

Walfront AS1392 EMF Meter with labeled components

Abbildung 1: Front view of the Walfront AS1392 EMF Meter with key components labeled. This image highlights the sensor position, LCD display, Mili Gauss / Micro Tesla switch button, ON/OFF button, and °C / °F switch button. The battery door is also indicated on the back.

Anwendungsszenarien

Various detection scenarios for the EMF meter

Abbildung 2: Examples of environments where the EMF meter can be used, including mobile computer equipment, plug-in devices, general products, high voltage lines, server rooms, and home appliances. This illustrates the versatility of the device for detecting electromagnetic radiation in various settings.

Aufstellen

Einlegen der Batterie

The Walfront AS1392 EMF Meter requires three (3) 1.5V AAA batteries (not included) for operation. Follow these steps to install the batteries:

  1. Suchen Sie die Abdeckung des Batteriefachs auf der Rückseite des Geräts.
  2. Slide the cover downwards or unclip it to open the compartment.
  3. Legen Sie drei AAA-Batterien ein und achten Sie dabei auf die richtige Polarität (+/-), wie im Batteriefach angegeben.
  4. Bringen Sie die Abdeckung des Batteriefachs wieder an und achten Sie darauf, dass sie hörbar einrastet.
Battery compartment of the EMF meter

Abbildung 3: Hinteren view of the EMF meter showing the open battery compartment, ready for AAA battery insertion. This image also lists key features of the device.

Bedienungsanleitung

Ein-/Ausschalten

  • Um das Gerät einzuschalten, halten Sie die Ein-/Ausschalter (power symbol) until the LCD screen illuminates.
  • Um das Gerät auszuschalten, halten Sie die Ein-/Ausschalter so lange, bis sich der Bildschirm ausschaltet.

Messmodi

The device automatically begins measuring electric and magnetic fields, as well as temperature, upon power-on. The sensor position is located at the top of the device.

EMF meter showing dual measurement capabilities

Abbildung 4: The EMF meter displaying both magnetic field and electric field detection capabilities, along with temperature measurement. A warning symbol for electromagnetic radiation is also shown.

Geräteschalten

  • Magnetic/Electric Field Units: Drücken Sie die MG/UT button to switch between milliGauss (mG) and microTesla (µT) units for electromagnetic field readings.
  • Temperatureinheiten: Drücken Sie die °C/°F-Taste to toggle between Celsius (°C) and Fahrenheit (°F) for temperature display.

Backlight and Data Hold

  • Hintergrundbeleuchtung: Drücken Sie kurz die Mode-Taste to turn the LCD backlight on or off, improving visibility in different lighting conditions.
  • Datenaufnahme: Halten Sie die Mode-Taste to activate the data hold function, which locks the current readings on the display. Press again to release.

Alarmfunktion

The device features an intelligent alarm system. If the detected electromagnetic radiation exceeds the preset safe value, the instrument will automatically trigger a sound and light alarm. This provides immediate notification of potentially high radiation levels.

EMF meter displaying high readings and alarm indication

Abbildung 5: The EMF meter's high-definition LCD screen showing a high reading (red display indicating alarm) and the intelligent alarm security guard feature. This instrument supports electric field/magnetic field alarm value setting.

Wartung

  • Reinigung: Reinigen Sie das Gerät mit einem weichen, trockenen Tuch. Verwenden Sie keine Scheuer- oder Lösungsmittel.
  • Lagerung: Bewahren Sie das Gerät an einem kühlen, trockenen Ort, geschützt vor direkter Sonneneinstrahlung und extremen Temperaturen, auf. Bei längerer Lagerung sollten die Batterien entfernt werden, um ein Auslaufen zu verhindern.
  • Batteriewechsel: Tauschen Sie die Batterien aus, sobald die Anzeige für niedrigen Batteriestand erscheint, um genaue Messwerte zu gewährleisten.
  • Auswirkungen vermeiden: Schützen Sie das Gerät vor Stürzen und starken Stößen, da diese die internen Komponenten beschädigen können.

Fehlerbehebung

Häufige Probleme und Lösungen

  • Das Gerät lässt sich nicht einschalten:
    • Prüfen Sie, ob die Batterien korrekt mit der richtigen Polarität eingelegt sind.
    • Ersetzen Sie sie durch neue AAA-Batterien.
  • Ungenaue oder schwankende Messwerte:
    • Ensure the device is held steadily and away from other electronic devices that might interfere with readings.
    • Verify that the sensor position is correctly oriented towards the source of measurement.
  • Das Display ist dunkel oder unleserlich:
    • Prüfen Sie den Batteriestand und tauschen Sie die Batterie gegebenenfalls aus.
    • Activate the backlight by briefly pressing the Mode button.
  • Der Alarm ertönt ununterbrochen:
    • This indicates high electromagnetic radiation. Move away from the source or investigate the environment.
    • Ensure the alarm threshold is set appropriately (if adjustable, though this model's setting is fixed at 40mG/0.4µT).

Technische Daten

Detailed specifications of the Walfront AS1392 EMF Meter

Abbildung 6: A comprehensive table detailing the technical specifications of the Walfront AS1392 EMF Meter.

SpezifikationDetail
ModellAS1392
MaterialABS-Kunststoff
EinheitmG (Electric Field); µT (Magnetic Field)
Genauigkeit±5% (50Hz or 60Hz), µT (50µT to 200µT)
Range (Electric)0~2000 mG
Range (Magnetic)0~200µT
Auflösung1mG, 0.1µT
Alarmschwelle40mG, 0.4µT
Temperaturbereich0–50 °C
Anzeige4-Digit LCD Display
Bandbreite testen30 Hz bis 300 Hz
Number Of AxesSingle Axis Sensor Head
SampPreis0.5 Sekunden
TestmodusSynchroner Dualmodus-Test
BereichsüberschreitungsanzeigeLCD displays "HI"
Arbeitstemperatur0~40°C
Relative Luftfeuchtigkeit (Betrieb)0 bis 80 %
Lagertemperatur-10~50°C
Relative Luftfeuchtigkeit (Lagerung)0 bis 70 %
Leistung3 * 1.5V AAA-Batterien (nicht im Lieferumfang enthalten)
GewichtCa. 108 g
GrößeCa. 130 * 50 * 27 mm / 5.1 * 2.0 * 1.1 Zoll

Garantie und Support

Specific warranty information for the Walfront SMART Sensor AS1392 EMF Meter is not provided in the product details. For warranty claims, technical support, or service inquiries, please contact the retailer or manufacturer directly using the contact information provided at the time of purchase. Retain your proof of purchase for any warranty-related requests.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.