FibroPool FP200
FibroPool 2 HP Swimming Pool Pump FP200 User Manual
Model: FP200 | Brand: FibroPool
Einführung
This manual provides essential information for the safe and efficient operation, installation, and maintenance of your FibroPool 2 HP Swimming Pool Pump (Model FP200). Please read this manual thoroughly before installation and operation to ensure proper use and to prevent damage or injury.
The FibroPool FP200 is a high-efficiency single-speed motor pump designed for in-ground pools and spas. It features a durable, corrosion-proof construction and is engineered for reliable performance.
Sicherheitshinweise
Always observe basic safety precautions when installing and operating this electrical equipment. Failure to follow instructions can result in serious injury or death.
- Ensure the pump is connected to a 240-volt, 60 Hz power supply only. It is not convertible to 120 volts.
- Installation must be performed by a qualified professional and comply with all local and national electrical and plumbing codes.
- Vor jeglichen Wartungs- oder Instandhaltungsarbeiten muss die Stromzufuhr zur Pumpe unterbrochen werden.
- Die Pumpe darf nicht trocken laufen. Vor dem Starten muss die Pumpe mit Wasser befüllt sein.
- Halten Sie Kinder vom Pumpen- und Pooltechnikbereich fern.
- Do not operate the pump if any parts are damaged or missing.
Produkt überview
The FibroPool FP200 pump is engineered for optimal performance and longevity. Key features include:
- 2 horsepower motor, pushing up to 8100 GPH at 3450 RPM.
- High-efficiency single-speed motor designed to reduce energy consumption.
- Durable, weatherproof chassis suitable for various environments.
- Integrated pedestal base for stable mounting.
- Super-sized 124 cubic-inch strainer basket with a clear twist-lock lid for easy inspection and cleaning.
- 2-inch unions included for simplified installation and servicing.

Abbildung 1: Seite view of the FibroPool FP200 Swimming Pool Pump, showing the motor and pump housing.

Abbildung 2: Gegenseite view of the FibroPool FP200 Swimming Pool Pump, highlighting the clear strainer lid.
Installation
Proper installation is crucial for the pump's performance and longevity. It is recommended that installation be performed by a certified pool technician or electrician.
Standortauswahl
- Installieren Sie die Pumpe so nah wie möglich am Pool, um Reibungsverluste durch die Rohrleitungen zu minimieren.
- Stellen Sie sicher, dass der Standort gut belüftet und vor direkter Sonneneinstrahlung und übermäßiger Feuchtigkeit geschützt ist.
- Provide adequate space around the pump for routine maintenance and servicing.
- Mount the pump on a solid, level base to prevent vibration and noise. The integrated pedestal base provides stability.
Sanitäranschlüsse
- The pump is equipped with 2-inch unions for easy connection to your existing plumbing system.
- Use appropriate PVC cement and primer for secure, leak-free connections.
- Ensure all plumbing is properly supported to avoid strain on the pump.
Elektrische Anschlüsse
WARNUNG: Electrical wiring should only be performed by a licensed electrician.
- The FibroPool FP200 operates on 240 volts, 60 Hz. Verify your power supply matches these requirements.
- Connect the pump to a dedicated circuit protected by a Ground Fault Circuit Interrupter (GFCI).
- The pump includes a 6-foot weatherproof power cable. Ensure all connections are secure and weatherproof.
- Refer to local electrical codes for specific wiring requirements.

Abbildung 3: Zurück view of the FibroPool FP200 pump, showing the electrical connection box and wiring.
Bedienungsanleitung
Ansaugen der Pumpe
Vor dem ersten Start der Pumpe oder nach dem Entleeren zur Wartung muss die Pumpe entlüftet werden.
- Stellen Sie sicher, dass alle Ventile geöffnet sind, damit das Wasser vom Pool zur Pumpe fließen kann.
- Remove the clear twist-lock lid from the strainer basket.
- Fill the strainer basket with water until it overflows.
- Replace the lid, ensuring it is securely twisted and sealed.
- Turn on the pump. The pump should prime within a few minutes. If not, turn off the pump, re-prime, and check for air leaks in the suction line.
Normalbetrieb
- Once primed, the pump will circulate water through your pool system.
- Monitor the pressure gauge on your filter system to ensure it is within the normal operating range.
- The clear top lid allows for easy visual inspection of the strainer basket to determine when cleaning is needed.
Wartung
Regular maintenance ensures the longevity and efficient operation of your FibroPool pump.
Strainer Basket Cleaning
The super-sized 124 cubic-inch basket has extra leaf-holding capacity, extending time between cleanings. However, regular inspection is recommended.
- Pumpe ausschalten und Stromzufuhr unterbrechen.
- Twist and remove the clear lid from the strainer housing.
- Nehmen Sie den Korb heraus und leeren Sie ihn.
- Spülen Sie den Korb gründlich mit Wasser aus.
- Prüfen Sie den O-Ring am Deckel auf Risse oder Abnutzung. Ersetzen Sie ihn gegebenenfalls.
- Return the basket to the housing, ensuring it is seated correctly.
- Replace the lid, twisting it securely to create a watertight seal.
- Entlüften Sie die Pumpe gegebenenfalls erneut, bevor Sie sie wieder in Betrieb nehmen.
Überwinterung
In areas subject to freezing temperatures, proper winterization is essential to prevent damage.
- Drain all water from the pump by removing the drain plugs.
- Lagern Sie die Pumpe nach Möglichkeit an einem trockenen, geschützten Ort.
- Consult a pool professional for comprehensive winterization procedures for your entire pool system.
Fehlerbehebung
This section provides solutions to common issues you may encounter with your FibroPool pump.
| Problem | Mögliche Ursache | Lösung |
|---|---|---|
| Pumpe startet nicht | No power, tripped breaker/GFCI, faulty wiring, motor issue. | Check power supply, reset breaker/GFCI. Verify electrical connections. If motor hums but doesn't start, contact a qualified technician. |
| Die Pumpe läuft, aber sie saugt nicht an oder hat einen geringen Förderstrom. | Air leak in suction line, clogged strainer basket, low water level in pool, closed valves, impeller obstruction. | Check and seal all suction line connections. Clean strainer basket. Ensure adequate pool water level. Open all necessary valves. Inspect impeller for debris. |
| Übermäßige Geräusche oder Vibrationen | Air leak, cavitation, loose mounting, worn bearings. | Check for air leaks. Ensure pump is properly primed. Tighten mounting bolts. If noise persists, motor bearings may be worn; contact service. |
| Wasser tritt aus der Pumpe aus | Loose plumbing connections, worn shaft seal, damaged O-rings. | Tighten plumbing connections. Inspect and replace O-rings on strainer lid and unions. A leaking shaft seal requires professional service. |
Technische Daten
Detailed technical specifications for the FibroPool 2 HP Swimming Pool Pump FP200.
| Attribut | Wert |
|---|---|
| Marke | FibroPool |
| Modellnummer | FP200 |
| PS | 2 PS |
| Bandtage | 240 Volt |
| Frequenz | 60 Hz |
| Wastage | 1.5 KW |
| Maximaler Durchfluss | 135 Gallonen pro Minute (8100 GPH) |
| Drehzahl | 3450 U/min |
| Material | Aluminum (Motor), Heavy Duty Plastic (Housing) |
| Artikelgewicht | 34.9 Pfund |
| Verpackungsabmessungen | 25 x 14.5 x 11.5 Zoll |
| Schallpegel | 45 dB |
| UPC | 850013473021 |

Figure 4: Performance Curve Chart. The FP200 curve illustrates the relationship between pump head (pressure) and flow rate.
Garantie und Support
For warranty information, technical support, or service inquiries, please contact FibroPool directly. Keep your purchase receipt as proof of purchase.
While specific warranty details are not provided in this manual, FibroPool is committed to providing quality products and customer satisfaction. For the most current warranty terms and conditions, please visit the official FibroPool webWebsite oder wenden Sie sich an die Kundendienstabteilung.
You can often find contact information on the product packaging, the manufacturer's webüber die Website oder über den Einzelhändler, bei dem das Produkt gekauft wurde.
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.