The ITECH IT6720 is a high-performance digital-control variable DC power supply designed for a wide range of applications, from laboratory research to production line testing. It provides stable and precise voltage and current output with automatic constant current (CC) and constant voltage (CV) conversion modes. Equipped with multiple protection functions, this power supply ensures safe and reliable operation.

ITECH IT6720 Variable DC Power Supply front view

Abbildung 1: Vorderseite view of the ITECH IT6720 Variable DC Power Supply.

Produkt überview

Frontplatten-Layout

Front panel with labeled components

Abbildung 2: Ausführlich view of the front panel, showing the CC/CV indicators, OCP/OVP indicators, memory save buttons, keyboard lock, voltage/current adjust knob, output ON/OFF button, and display switch button.

Layout der Rückseite

Rear panel with labeled components

Abbildung 3: Ausführlich view of the rear panel, indicating the power switch, AC power input, 9-pin connector (for factory use only), and cooling fan.

Aufstellen

  1. Stromanschluss: Connect the supplied power cord to the AC power input on the rear panel (Figure 3). Ensure the power switch is in the OFF position before connecting.
  2. Bandtage Auswahl: Überprüfen Sie die Lautstärketage selector switch on the rear panel is set to the correct local AC voltage (110V or 220V). Adjust if necessary using a small flat-head screwdriver.
  3. Ausgangsverbindungen: Connect your load to the output terminals on the front panel. The red terminal is positive (+), the black terminal is negative (-), and the green terminal is ground. Ensure secure connections.
  4. Erstes Einschalten: Flip the power switch on the rear panel to the ON position. The display on the front panel should illuminate.

Video 1: A brief demonstration of the ITECH IT6700 series DC power supply, including power-on and basic operation.

Bedienungsanleitung

  1. Vol. einstellentage und Strom: Use the large rotary knob to adjust the voltage and current values. Press the 'Shift' button to toggle between coarse and fine adjustment modes for precise control. The display will show the set values.
  2. Ausgang EIN/AUS: Press the 'On/off' button to enable or disable the output. The display will indicate if the output is active.
  3. CC/CV Automatic Conversion: Das Netzteil schaltet automatisch zwischen Konstantlautstärke umtage (CV) and Constant Current (CC) modes depending on the load. The corresponding indicator (CC or CV) on the display will light up.
  4. Schutzfunktionen: The unit is equipped with Over Current Protection (OCP), Over Voltage Protection (OVP), and Over Temperature Protection (OTP). If any of these conditions are met, the output will shut down and the respective indicator will light up.
  5. Speicherfunktionen: Use the 'Save' and 'Prog' buttons (A, B, C, D) to store and recall frequently used voltage and current settings. Refer to the detailed manual for specific programming steps.
  6. Tastatursperre: The 'Lock' button can be used to prevent accidental changes to settings during operation.

Video 2: Ein überview of the IT6700 DC Power Supply's features, including its bright display, high resolution, and CV/CC modes.

Key lock feature on power supply

Figure 4: The key lock feature helps prevent accidental changes to settings.

Adjust step value settings for voltage und aktuelle

Figure 5: Table illustrating the different adjustment step values for voltage and current (e.g., 1V, 0.1V, 0.01V for voltage; 1A, 0.1A, 0.01A, 0.001A for current).

Wartung

Sicherungswechsel

The ITECH IT6720 power supply is equipped with a replaceable fuse for protection against overcurrent. If the unit fails to power on or experiences unexpected shutdowns, the fuse may need replacement. The fuse holder is located on the rear panel, near the AC power input.

  1. Stromversorgung trennen: Ensure the power supply is completely disconnected from the AC mains before attempting any maintenance.
  2. Locate Fuse Holder: Identify the fuse holder on the rear panel (refer to Figure 3). It is typically a small, cylindrical cap that can be twisted or pulled out.
  3. Alte Sicherung entfernen: Use a small flat-head screwdriver or your fingernail to gently pry open or twist the fuse holder cap. Carefully remove the old fuse.
  4. Check Fuse Rating: The required fuse rating is printed on the rear panel near the fuse holder. For 110V AC operation, the fuse is typically 3.15A/250V. For 220V AC operation, it is 1.5A/250V. Always replace with a fuse of the exact same type and rating.
  5. Neue Sicherung einsetzen: Place the new fuse into the fuse holder cap and reinsert it into the power supply, ensuring it is securely seated.
  6. Stromversorgung wiederherstellen: Reconnect the power supply to the AC mains and test its operation.

Note: If the fuse blows repeatedly, there may be an underlying issue with the unit or your electrical setup. Contact technical support for assistance.

Technische Daten

SpezifikationWert
Ausgangsvolumentage0 bis 60 V
Ausgangsstrom0-5A
Leistung0-100 W
Bandtage-Auflösung0.01 V
Aktuelle Auflösung0.001 A
Bandtage Genauigkeit<0.05%+10mV
Aktuelle Genauigkeit< 0.1 % + 2 mA
Produktabmessungen (L x B x H)11.1 x 6.9 x 3.5 Zoll
Artikelgewicht7.7 Pfund
KühlmethodeLuft

For a complete list of specifications, please refer to the official product documentation.

Dimensions of the ITECH IT6720 power supply

Figure 6: Product dimensions of the ITECH IT6720.

Power curve graph for ITECH IT6720

Figure 7: Power curve illustrating the voltage and current capabilities within the rated power.

Fehlerbehebung

  • Das Gerät lässt sich nicht einschalten:
    1. Check if the power cord is securely connected to both the unit and the AC outlet.
    2. Verify the power switch on the rear panel is in the ON position.
    3. Inspect the fuse on the rear panel. If blown, replace it with a fuse of the correct rating (refer to Maintenance section).
  • Keine Ausgangslautstärketage/aktuell:
    1. Ensure the output ON/OFF button on the front panel is enabled.
    2. Check if any protection indicators (OCP, OVP, OTP) are lit. If so, resolve the overload/overvoltage/overtemperature condition and reset the unit.
    3. Stellen Sie sicher, dass die Lautstärketage und die aktuellen Einstellungen sind nicht auf Null gesetzt.
  • Difficulty with user interface/modes:
    The IT6720 uses a single control knob with multiple modes. Refer to the detailed user manual (PDF link provided in product documents) for a comprehensive explanation of each mode (Mode A, B, C, D) and how to navigate them using the 'Shift' and 'Setup' buttons. Practice adjusting values in different modes to become familiar with the interface.

Garantie und Support

ITECH provides professional technical support for its products both before and after sale. For any technical inquiries, operational assistance, or warranty claims, please contact ITECH customer service directly.

Refer to the official ITECH website or the documentation included with your product for the most up-to-date contact information and warranty details.

Contact Technical Team email address

Figure 8: Contact information for ITECH Technical Team.

Zugehörige Dokumente - IT6720

Vorview ITECH IT6720 Digitales Steuernetzteil – Benutzerhandbuch
Ausführliche Bedienungsanleitung für das digitale Steuernetzteil ITECH IT6720 mit detaillierten Informationen zu Funktionen, Bedienung, Sicherheitsvorkehrungen, Spezifikationen und Fehlerbehebung.
Vorview Benutzerhandbuch und Einrichtungsanleitung für die iTech Fusion Smartwatch
Umfassende Anleitung für die iTech Fusion Smartwatch mit Informationen zu Einrichtung, Funktionen, Aktivitätstracking, Schlafüberwachung, Herzfrequenzmessung, Sportmodi und Pflegehinweisen. Erfahren Sie, wie Sie die iTech Wearables-App verbinden, synchronisieren und alle Funktionen nutzen.
Vorview ITECH IT-N6900 Programmierbares Gleichstromnetzteil – Funktionen, Anwendungen und Spezifikationen
Entdecken Sie das programmierbare Gleichstromnetzteil der ITECH IT-N6900-Serie mit Ausgangsoptionen von 60 V/150 V und 850 W/1500 W. Dieses Dokument beschreibt die erweiterten Funktionen wie CC/CV-Priorität, Listenprogrammierung, Datenprotokollierung, umfassenden Schutz und Anschlussmöglichkeiten. Enthält detaillierte technische Spezifikationen und Anwendungsbereiche für Industrie und Forschung.
Vorview ITECH IT-N6700 Series Programmable DC Power Supply User Manual
Explore the IT-N6700 Series Programmable DC Power Supply from ITECH. This user manual provides comprehensive details on features, installation, operation, safety, and technical specifications for reliable power solutions.
Vorview Benutzerhandbuch für die IT2702/IT2704-Serie – ITECH Mehrkanal-Modular-Stromversorgungssystem
Benutzerhandbuch für das modulare Mehrkanal-Stromversorgungssystem der Serie ITECH IT2702/IT2704. Dieses Handbuch enthält detaillierte Informationen zu Funktionen, Spezifikationen, Sicherheitsvorkehrungen und Installation.
Vorview iTECH Sport Fitness Tracker Benutzerhandbuch
Umfassendes Benutzerhandbuch für den iTECH Sport Fitness Tracker mit Informationen zu Einrichtung, Funktionen, Tragen und Pflege sowie gesetzlichen Bestimmungen.