1. Einleitung
This manual provides comprehensive instructions for the installation, operation, and maintenance of the Honeywell Home Wireless Receiver Relay, Model R4H910RF1004. This device is designed as a replacement relay module for wireless T6R thermostats and is compatible with Honeywell Home T4 and T6 series wireless thermostats. Please read this manual thoroughly before installation and use to ensure proper functionality and safety.
2. Sicherheitshinweise
Beachten Sie stets die folgenden Sicherheitsvorkehrungen, um Schäden am Produkt oder Verletzungen zu vermeiden:
- Installation must be carried out by a qualified electrician and in accordance with all local wiring regulations.
- Disconnect power to the heating system at the main circuit breaker before installing or servicing the relay.
- Das Gerät darf weder Wasser, hoher Luftfeuchtigkeit noch extremen Temperaturen ausgesetzt werden.
- Versuchen Sie nicht, das Gerät zu öffnen oder zu reparieren. Überlassen Sie alle Wartungsarbeiten qualifiziertem Fachpersonal.
- Ensure all connections are secure and correctly wired to avoid electrical hazards.
3. Packungsinhalt
Überprüfen Sie, ob alle Artikel im Paket vorhanden sind:
- 1 x Honeywell 2-Channel Wireless Receiver Box (R6H911RF4018)
- 1 x Set of Stickers
- 1 x Fixing Kit (screws and wall plugs)
4. Produktüberschreitungview
The Honeywell Home Wireless Receiver Relay acts as a switching device for your heating system, receiving commands wirelessly from a compatible thermostat. It features a compact design for wall mounting.

Abbildung 1: Vorderseite view of the Honeywell Home Wireless Receiver Relay. This image displays the compact white unit, typically featuring indicator lights for power and wireless connection status.
5. Einrichtung und Installation
Follow these steps to install your wireless receiver relay:
5.1 Montage des Empfängers
- Wählen Sie einen Standort: Select a suitable wall-mounted location near your boiler or heating system, ensuring it is within wireless range of your thermostat and away from metal objects that could interfere with the signal.
- Stromversorgung trennen: Turn off the main power supply to your heating system at the consumer unit/fuse box. Verify that the power is off before proceeding.
- Vorbereitung zur Montage: Use the provided fixing kit. Mark the drilling points on the wall using the receiver as a template.
- Drill and Secure: Drill holes, insert wall plugs, and secure the receiver to the wall using the screws.
5.2 Anschließen des Empfängers
Refer to your boiler's instruction manual for specific wiring diagrams. The receiver typically requires a permanent live, neutral, and a switched live connection to the boiler.
- Öffne das Casing: Öffnen Sie den Empfänger vorsichtig.asing to access the wiring terminals.
- Kabel anschließen: Connect the power supply and boiler control wires to the appropriate terminals as indicated on the receiver's internal label and your boiler's manual. Ensure all connections are tight and secure.
- Schließen Sie Casing: Schließen Sie den Empfänger casing sicher.
- Strom wiederherstellen: Restore power to the heating system at the main circuit breaker. The receiver's power indicator light should illuminate.
6. Bedienungsanleitung
The primary operation of the wireless receiver relay involves pairing it with a compatible Honeywell Home wireless thermostat (T4 or T6 series).
6.1 Pairing with a Thermostat
The receiver and thermostat must be paired to communicate wirelessly. This process typically involves a binding procedure:
- Initiate Binding Mode on Receiver: Press and hold the binding button on the receiver (refer to the receiver's specific instructions for button location and duration). An indicator light will typically flash to confirm binding mode.
- Initiate Binding Mode on Thermostat: Follow the instructions in your Honeywell Home T4 or T6 thermostat manual to put it into binding or pairing mode.
- Kopplung bestätigen: Once successfully paired, the indicator lights on both the receiver and thermostat should change to a solid state, indicating a successful connection.
- Testsystem: After pairing, test the system by adjusting the temperature on the thermostat to ensure the boiler responds correctly via the receiver.
7. Wartung
The Honeywell Home Wireless Receiver Relay requires minimal maintenance.
- Reinigung: Wischen Sie das Gerät außen mit einem weichen, trockenen Tuch ab. Verwenden Sie keine Scheuer- oder Lösungsmittel.
- Inspektion: Überprüfen Sie regelmäßig, ob sichtbare Schäden am c vorhanden sind.asing oder Verkabelung.
- Firmware-Updates: If applicable, refer to the Honeywell Home website or your thermostat's manual for information on firmware updates.
8. Fehlerbehebung
If you encounter issues with your wireless receiver relay, consult the table below:
| Problem | Mögliche Ursache | Lösung |
|---|---|---|
| Receiver lässt sich nicht einschalten | Keine Stromversorgung; falsche Verkabelung. | Check main power supply and wiring connections. Ensure power is restored. |
| Cannot pair with thermostat | Incorrect binding procedure; out of range; interference; incompatible devices. | Ensure both devices are in binding mode simultaneously. Move thermostat closer to the receiver. Check for sources of wireless interference. Notiz: Some relays are factory-configured to specific thermostats and may not be universally interchangeable. If replacing an old relay, ensure the new unit is compatible or can be re-paired with your existing thermostat. |
| Heizungsanlage reagiert nicht | No wireless connection; wiring issue; thermostat fault; boiler fault. | Verify successful pairing. Check wiring to the boiler. Consult thermostat or boiler manual for troubleshooting. |
| Intermittierende Verbindung | Wireless interference; weak signal. | Relocate receiver or thermostat to improve signal strength. Avoid placing near large metal objects or other wireless devices. |
9. Spezifikationen
| Besonderheit | Detail |
|---|---|
| Produktmodellnummer | R4H910RF1004 |
| Internal Receiver Box Model | R6H911RF4018 |
| Hersteller | Wohnen |
| Produktabmessungen (L x B x H) | 25 x 7 x 25 cm |
| Gewicht | 300 Gramm |
| Steckertyp | Plug-in |
| Kontaktmaterial | Kupfer |
| Kontakttyp | Normalerweise offen |
| Montagetyp | Wandhalterung |
| Betriebsart | Automatisch |
| Im Lieferumfang enthaltene Komponenten | Wi-Fi Heating Control (Receiver Box) |
10. Garantie und Support
For warranty information and technical support, please refer to the documentation provided with your original purchase or visit the official Resideo/Honeywell Home webBewahren Sie Ihren Kaufbeleg für Garantieansprüche auf.
Online-Ressourcen: For additional support, FAQs, and product registration, visit the Wohnen webWebsite oder die Honeywell-Startseite webWebsite.