1. Produktüberschreitungview
The Akozon YF-4 DC 12V Adjustable Cycle Delay Timer Relay Module is a versatile control unit designed for various applications requiring precise timing. It features a dual digital display for setting delay ON and delay OFF times, offering a wide adjustable range from 0.1 seconds to 999 hours. This module is commonly used to control the start and stop of devices such as solenoid valves, water pumps, motors, and string lights, providing six distinct functional modes to meet diverse application needs.

Abbildung 1: Vorderseite view of the Akozon YF-4 Cycle Delay Timer Relay Module.
2. Spezifikationen
| Besonderheit | Beschreibung |
|---|---|
| Marke | Akozon |
| Modellnummer | YF-4 (Akozon409q6pce53) |
| Betriebsart | Automatisch |
| Spule Voltage | 12 Volt (DC) |
| Laststeuerung | AC/DC loads within 5A |
| Zeitbereich | 0.1 Sekunden bis 999 Stunden (einstellbar) |
| Anzeige | Duales LED-Digitaldisplay |
| Artikelgewicht | 34 Gramm |
| Herkunft | China |
3. Einrichtung und Installation
Before installation, ensure the power supply is disconnected. Connect the module according to the wiring diagram provided. The module is designed for easy integration into various systems. Ensure all connections are secure to prevent malfunction or damage.

Abbildung 2: Rückseite view showing the terminal block for wiring connections.
Video 1: This video demonstrates the basic wiring and initial setup of a similar timer switch, which can be used as a reference for connecting the Akozon YF-4 module.
4. Bedienungsanleitung
4.1 Funktionsmodi
The module offers six functional modes (P1-1 to P1-6) for various timing requirements:
- P1-1: After delay time T1, the relay pulls in.
- P1-2: After delay time T1, the relay releases.
- P1-3: After delay time T1, the relay pulls in. After delay time T2, the relay releases.
- P1-4: After delay time T1, the relay releases. After delay time T2, the relay pulls in.
- P1-5: After delay time T1, the relay pulls in. After delay time T2, the relay releases, and the cycle repeats.
- P1-6: After delay time T1, the relay releases. After delay time T2, the relay pulls in, and the cycle repeats.
4.2 Button Settings
The module features four buttons for configuration and operation:

Figure 3: Button layout and display indicators.
- Einstellungsschaltfläche (Zahnradsymbol): Press and hold for 2 seconds to enter function settings. Short press to switch between parameter settings.
- Increase Button (Up Arrow): Increases the time value.
- Decrease Button (Down Arrow): Decreases the time value.
- Confirm Button (Power Icon): Startet oder stoppt den Zeitmessvorgang.
4.3 Timing Range Explanation
The timing range varies based on the decimal point position:
- XX.X: Timing range 0.1 seconds to 99.9 seconds.
- XXX: Timing range 1 second to 999 seconds.
- XXX.: Timing range 1 minute to 999 minutes.
- XX.X.: Timing range 1 hour to 999 hours.

Figure 4: Display indicating the wide delay range.
Video 2: This video demonstrates the adjustable timing features of a DC 12V cycle timer relay module, showing how to set the delay from 0.1 seconds to 999 hours.
5. Wartung
The Akozon YF-4 module is designed for durability and requires minimal maintenance. Keep the device clean and free from dust and moisture. Avoid exposing it to extreme temperatures or corrosive environments. Regularly check wiring connections for tightness and signs of wear. If the device is not functioning correctly, refer to the troubleshooting section before attempting any repairs.
6. Fehlerbehebung
If you encounter issues with your Akozon YF-4 module, consider the following common troubleshooting steps:
- Kein Strom/Display aus: Check the 12V DC power supply connection. Ensure the power source is active and correctly wired.
- Relais aktiviert nicht: Verify the functional mode (P1-1 to P1-6) and ensure the T1/T2 delay times are set correctly. Check the load connection and ensure it is within the 5A AC/DC limit.
- Falsches Timing: Re-check the decimal point setting for the timing range (XX.X, XXX, XXX., XX.X.). Ensure the desired time unit (seconds, minutes, hours) is selected.
- Tasten reagieren nicht: Ensure the module is powered on. If the issue persists, try resetting the device by disconnecting and reconnecting power.
Sollten die Probleme durch diese Schritte weiterhin bestehen, wenden Sie sich bitte an den Kundendienst.
7. Garantie und Support
This Akozon product comes with a standard manufacturer's warranty. Please refer to the packaging or the seller's website for specific warranty terms and conditions. For technical support, product inquiries, or warranty claims, please contact your point of purchase or Akozon customer service. Keep your purchase receipt as proof of purchase.