1. Produktüberschreitungview
The Daytech Wireless Caregiver Pager System is designed to provide peace of mind and independence for individuals needing assistance, as well as for their caregivers. This wireless alert system allows patients or elderly persons to quickly call for help with a simple press of a button, ensuring timely assistance in private households, hospitals, nursing homes, and other care environments. The system offers a reliable connection with a working range of up to 320 feet (120 meters).

Figure 1: Complete Daytech Wireless Caregiver Pager System components.
2. Lieferumfang
Your Daytech Wireless Caregiver Pager System package includes the following components:
- 3 x Steckdosenempfänger
- 2 x SOS Watch Pagers
- 2 x SOS Call Buttons (with lanyards)
- Required 12V batteries (pre-installed or included for call buttons)
- Benutzerhandbuch (dieses Dokument)
Abbildung 2: Überview of system components and common usage scenarios.
3. Erste Schritte (Einrichtung)
3.1 Empfänger-Setup
Schließen Sie den Empfänger an: Plug the receiver into a standard wall socket. The receiver will emit a sound and its LED light will flash, indicating it is powered on.
Klingelton auswählen: Press the Forward Button or Backward Button on the side of the receiver to cycle through the 20 available ringtones. Choose your preferred alert sound.
Lautstärke anpassen: Press the Volume Control button on the side of the receiver to adjust the volume level. There are 5 levels, ranging from 0dB (silent) to 110dB (loudest).
Figure 3: Receiver controls and dimensions.
3.2 Pairing Transmitters (Call Buttons & Watch Pagers)
To ensure your call buttons and watch pagers communicate with the receiver, they must be paired:
Kopplungsmodus aktivieren: Press and hold the Volume Control button on the receiver until the LED light flashes and the receiver emits a "ding-dong" sound. This indicates the receiver is in pairing mode.
Sender aktivieren: Within 5 seconds of the receiver entering pairing mode, press the SOS button on the watch pager or the CALL button on the call button unit. The receiver will emit a "ding-dong" sound and its LED light will flash, confirming successful pairing.
Kopplung bestätigen: Press the button on the transmitter again. The receiver should respond with the selected ringtone and flash, confirming the pairing is active.
Pair Additional Transmitters: Repeat steps 1-3 for each additional call button or watch pager you wish to pair with the receiver.
Abbildung 4: Visuelle Anleitung zum Koppeln von Sendern.
Video: Learn how to pair multiple call buttons with your Daytech Caregiver Pager System for expanded coverage.
3.3 Installation des Rufknopfes
The call buttons offer flexible installation options:
Lanyard-Befestigung: Attach the included lanyard to the call button for easy wearing around the neck, ensuring it's always accessible.
Wandhalterung: Use the provided 3M double-sided adhesive patches to affix the call button to a wall or other flat surface. This is ideal for fixed locations like bathrooms or beside a bed.
Figure 5: Call button installation methods.
4. Bedienung
4.1 Using the Pager System
Once set up, operating the Daytech Caregiver Pager System is straightforward:
Initiate Alert: When assistance is needed, simply press the large SOS button on the watch pager or the CALL button on the call button unit. This sends a wireless signal to the paired receiver(s).
Receive Alert: The receiver(s) will sound the selected ringtone and flash their LED light, immediately notifying the caregiver of the need for assistance.
Video: See how easy it is to get assistance with just a push of a button.
4.2 Effektive Reichweite
The system boasts a working distance of up to 320 feet (120 meters) in an open area. This allows caregivers to move freely around the house or facility while remaining within range to receive alerts.
Figure 6: Wireless working distance illustration.
4.3 Anwendungsszenarien
This versatile system is suitable for various care needs:
- Altenpflege
- Patient/Disabled Care
- Kinderbetreuung
- Pregnancy Care
Video: Ein überview of the Daytech Caregiver Pager Call Button system and its applications.
5. Wartung
5.1 Batteriewechsel
The call buttons and watch pagers are battery-powered. When the battery is low, the performance may degrade. Replace batteries as needed.
Batterie des Rufknopfes: The call button uses a 12V battery. To replace, carefully open the back cover using a small screwdriver, remove the old battery, insert the new one with correct polarity, and secure the cover.
Watch Pager Battery: The watch pager uses a CR2032 battery. To replace, carefully open the watch casing, remove the old battery, insert the new one with correct polarity, and close the casing sicher.
Video: Instructions on how to attach the lanyard and replace the battery in the call button.
Video: A guide on how to open the watch pager for battery replacement.
5.2 Pflege und Reinigung
The call button unit is splash-proof (IP55 rated) and can withstand splashes of water, making it suitable for use in bathrooms or near sinks. However, it is NOT designed to be immersed in water. The watch pager and alert button unit cannot be immersed in water and should be removed before bathing or showering.
Figure 7: Call button IP55 waterproof rating and temperature range.
To clean the units, wipe them with a soft, damp Tuch. Verwenden Sie keine scharfen Chemikalien oder Scheuermittel.
6. Fehlerbehebung
If you encounter any issues with your Daytech Wireless Caregiver Pager System, please refer to the table below for common problems and their solutions:
| Problem | Mögliche Ursache | Lösung |
|---|---|---|
| Der Empfänger gibt beim Drücken der Taste keinen Ton von sich und blinkt auch nicht. | Not paired, out of range, low battery in transmitter. | Re-pair the transmitter with the receiver. Move closer to the receiver. Replace transmitter battery. |
| Short working range. | Obstructions (thick walls, metal objects), electromagnetic interference, low battery. | Relocate receiver to a more central position. Avoid placing near large metal objects. Replace transmitter battery. |
| Receiver constantly beeps or flashes. | Stuck button on transmitter, interference. | Check transmitter button for obstruction. Unplug and re-plug receiver. |
| Cannot change ringtone or volume. | Falscher Tastendruck. | Ensure you are pressing the correct Forward/Backward or Volume buttons as described in Section 3.1. |
7. Technische Daten
| Besonderheit | Spezifikation |
|---|---|
| Modellnummer | E-01W |
| Kontrollmethode | Berühren |
| Maximale Reichweite | 320 Fuß (120 m) |
| Klingeltöne | 20 auswählbare Glockenspiele |
| Lautstärkepegel | 5 Stufen (0-110 dB) |
| Wasserdichtigkeitsgrad der Ruftaste | IP55 (spritzwassergeschützt) |
| Batterie für Rufknopf | 1 x 12V Alkaline battery (included) |
| Batterie für Uhrenpager | CR2032 (enthalten) |
| Stromquelle (Empfänger) | Netzstecker (260 Volt) |
| Artikelgewicht | 1.15 Pfund (Gesamtpaket) |
| Verpackungsabmessungen | 5.83 x 5.2 x 4.06 Zoll |
8. Garantie und Support
Daytech is committed to providing reliable products and excellent customer service. Your Daytech Wireless Caregiver Pager System comes with a full year’s warranty and a money-back guarantee.
For any questions, troubleshooting assistance, or support needs, please contact our round-the-clock customer service team. We are here to ensure your peace of mind when caring for your loved ones.