LBS RBK1-1RR

Bedienungsanleitung

LBS Touchless Infrared Induction EXIT Button Switch with Remote Control

Model: RBK1-1RR

1. Einleitung

This manual provides detailed instructions for the installation, operation, and maintenance of the LBS Touchless Infrared Induction EXIT Button Switch with Remote Control. Please read this manual thoroughly before installation and use to ensure proper functionality and safety.

2. Produktüberschreitungview und Funktionen

The LBS Touchless Infrared Induction EXIT Button Switch is designed for access control security systems, offering a hygienic and convenient way to exit. It features touchless operation via infrared induction and includes a remote control for added flexibility.

LBS Touchless Exit Button Switch and Remote Control

Figure 2.1: LBS Touchless Exit Button Switch and Remote Control. The image shows the rectangular stainless steel exit button with a central "No Touch" infrared sensor and a separate black remote control with a blue button area and a keychain attachment.

  • Berührungslose Bedienung: Infrared induction for hygienic exit.
  • Fernbedienung: Includes a single-channel metal remote, capable of adding up to 16 remotes with a range of 15-30 meters (49-98 feet).
  • Dual LED Indicators: Blue LED for standby mode, Green LED for active mode.
  • Langlebige Konstruktion: Panel made of 304 stainless steel, tested for over 100,000 continuous clicks.
  • Breite Kompatibilität: NO/NC/COM contact output, compatible with most electronic equipment, keyboard access control systems, and door phones.

3. Spezifikationen

ParameterWert
Dimension115L×70W×26H mm (4.53L×2.76W×1.02H in)
LeistungsaufnahmeDC12V/24V
AusgangskontaktSchließer/Öffner/Kombination
ModusTouchless + Remote (Self Reset)
Remote-KapazitätSingle channel, max 16 remotes
Fernentfernung15-30 Meter (49-98 Fuß)
Plattenmaterial304 Edelstahl
Mechanische Lebensdauer> 100,000 times (aging test)
Geeigneter TürtypHollow door
Betriebstemperatur-20~55℃ (14~131℉)
Suitable Humidity0%~95% (relative humidity)
Erfassungsbereich50-100 mm (1.97-3.94 Zoll)
LED-AnzeigeBlue (Standby), Green (Active)
Gewicht0.3 kg (10.58 oz)
LBS Touchless Exit Button Switch Dimensions

Figure 3.1: Dimensional drawing of the LBS Touchless Exit Button Switch and its remote control. The diagram shows precise measurements in millimeters and inches for both the button panel and the remote.

4. Packungsinhalt

Bitte überprüfen Sie den Paketinhalt nach Erhalt. Sollten Artikel fehlen oder beschädigt sein, kontaktieren Sie bitte umgehend Ihren Lieferanten.

  • 1 x LBS Touchless Infrared Induction EXIT Button Switch
  • 1 x Fernbedienung

5. Einrichtung und Installation

Proper installation is crucial for the optimal performance and safety of the device. It is recommended that installation be performed by a qualified technician.

5.1 Schaltplan

LBS Touchless Exit Button Switch Wiring Diagram

Abbildung 5.1: Rückseite view of the LBS Touchless Exit Button Switch showing the wiring terminals. Labels indicate Red: +12V, Black: GND, Green: NO, Yellow: COM, White: NC.

Connect the wires according to the following scheme:

  • Rot: +12V (Power Supply Positive)
  • Schwarz: GND (Masse)
  • Grün: NO (Normally Open Contact)
  • Gelb: COM (Common Contact)
  • Weiß: NC (Normally Closed Contact)

Stellen Sie sicher, dass alle Verbindungen sicher und isoliert sind, um Kurzschlüsse zu vermeiden.

5.2 Mounting the Exit Button

  1. Choose a suitable location near the exit point, typically at standard switch height.
  2. Markieren Sie die Bohrpunkte an der Wand, indem Sie die Befestigungslöcher des Knopfes als Schablone verwenden.
  3. Bohren Sie Löcher und setzen Sie bei Bedarf Dübel ein.
  4. Route the necessary wiring from your access control system to the installation point.
  5. Connect the wires to the button's terminals as per the wiring diagram (Section 5.1).
  6. Secure the exit button to the wall using appropriate screws.

6. Bedienung

6.1 Touchless Exit Button Operation

  1. Ensure the exit button is powered on. The LED indicator will be blue (Standby).
  2. To activate the exit function, place your hand or an object within the detection range of 50-100mm (1.97-3.94 inches) from the sensor.
  3. The LED indicator will change to green (Active), and the exit contact will momentarily activate, triggering the connected access control device (e.g., unlocking a door).
  4. The button will automatically reset after activation.

6.2 Fernbedienungsbetrieb

  1. Drücken Sie die Taste auf der Fernbedienung.
  2. The remote will transmit a signal to the exit button, activating the exit function.
  3. The remote control has a range of 15-30 meters (49-98 feet) depending on environmental conditions.

6.3 Adding/Deleting Remote Controls

The specific procedure for adding or deleting remote controls may vary slightly depending on the version of the device. Typically, there is a learning button or jumper on the main board of the exit button. Refer to the detailed instructions provided with your access control system or contact technical support for precise steps.

  • To add a remote: Press the learning button on the exit button's circuit board (usually a small button or jumper), then press the button on the remote control you wish to add. The LED may flash to confirm.
  • To delete all remotes: Hold the learning button for several seconds until the LED indicates successful deletion (e.g., rapid flashing).

A maximum of 16 remotes can be added to a single exit button.

7. Wartung

  • Reinigung: Wipe the stainless steel panel with a soft, damp Verwenden Sie kein scheuerndes Reinigungs- oder Lösungsmittel, da diese die Oberfläche oder elektronische Bauteile beschädigen könnten.
  • Sensorbereich: Keep the infrared sensor area clean and free from obstructions to ensure accurate detection.
  • Regelmäßige Kontrollen: Überprüfen Sie regelmäßig die Kabelverbindungen auf Lockerheit oder Beschädigung.
  • Umgebungsbedingungen: Um die Lebensdauer des Geräts zu verlängern, muss sichergestellt werden, dass die Betriebsumgebung innerhalb der vorgegebenen Temperatur- und Feuchtigkeitsbereiche bleibt.

8. Fehlerbehebung

ProblemMögliche UrsacheLösung
Button not responding to touchless activation.
  • Kein Strom.
  • Sensor verstopft oder verschmutzt.
  • Detection range issue.
  • Verdrahtungsfehler.
  • Check power supply (DC12V/24V).
  • Reinigen Sie den Sensorbereich.
  • Ensure hand/object is within 50-100mm.
  • Überprüfen Sie die Verdrahtungsanschlüsse (Abschnitt 5.1).
Fernbedienung funktioniert nicht.
  • Fernbedienung nicht gekoppelt.
  • Batterie der Fernbedienung schwach/leer.
  • Außer Reichweite.
  • Pair the remote control (Section 6.3).
  • Batterie der Fernbedienung gegebenenfalls austauschen.
  • Move closer to the exit button.
Die LED-Anzeige leuchtet nicht.
  • Kein Strom.
  • Defekte LED.
  • Überprüfen Sie die Stromversorgung und die Verkabelung.
  • Contact technical support if power is confirmed.

Sollte das Problem nach dem Ausprobieren dieser Lösungsansätze weiterhin bestehen, wenden Sie sich bitte an den technischen Support.

9. Garantie und Support

LBS products are manufactured to high quality standards. This product comes with a standard manufacturer's warranty against defects in materials and workmanship. For specific warranty terms and conditions, please refer to the warranty card included with your purchase or contact your retailer.

For technical support, troubleshooting assistance, or inquiries regarding parts and service, please contact your point of purchase or visit the official LBS webWebsite für Kontaktinformationen.

© 2024 LBS. All rights reserved.

Die Informationen in diesem Handbuch können ohne Vorankündigung geändert werden.