Oswerpon HBP1500II(230V)

Oswerpon Pool Pump User Manual

Model: HBP1500II(230V)

For 2 HP 6900 GPH Self-Priming Pool Pumps

Einführung

This manual provides essential information for the safe and efficient operation of your Oswerpon 2 HP Dual Voltage Pool Pump. Designed for both above-ground and in-ground pools, this self-priming pump ensures powerful water circulation, maintaining clarity and health for pools ranging from 15,000 to 31,000 gallons. Please read this manual thoroughly before installation and operation.

Sicherheitshinweise

Your safety is paramount. This pool pump is UL-certified, meeting international safety standards. Always adhere to the following precautions:

  • Elektrische Sicherheit: Ensure proper grounding. The grounding wire provides additional safety protection.
  • Überhitzungsschutz: The pump features built-in automatic overheating and overload protection.
  • Grundierung: VORSICHT: Under no circumstances should the pump be switched on before being filled with water. This could potentially cause harm to the mechanical seals and impeller. It is imperative to verify the water level within the pump before initiating operation. Initially, ensure the presence of the pump's drain plug; if inserted, water must be added accordingly. Any surplus water will naturally permeate into the pipes, facilitating the generation of suction.
  • Wassertemperatur: Do not operate the pump with water temperatures exceeding 104°F (40°C).
  • Installation: Installation should be performed by a qualified professional in accordance with all local and national electrical and plumbing codes.

For detailed safety guidelines, refer to the Sicherheitsinformationen (PDF) dokumentieren.

Produkt überview

The Oswerpon Pool Pump is engineered for high performance and durability. Its robust design includes a commercial-grade reinforced thermoplastic body and a powerful pure copper motor.

Oswerpon Pool Pump with included accessories

Figure 1: Oswerpon Pool Pump with various connection fittings and sealing tape.

Hauptmerkmale:

  • Leistungsstarker Motor: 2 HP pure copper motor for efficient, stable, and safe operation with long service life.
  • Duale Lautstärketage: Seamlessly accommodates 115V or 230V input, with an integrated voltage Einstellknopf.
  • Hohe Durchflussrate: Achieves a maximum flow rate of 67.37 GPM (6900 GPH) and a maximum head of 55.7 FT.
  • Selbstansaugend: Designed for automatic self-priming.
  • Siebkorb: Oversized, transparent filter basket for easy debris removal and inspection.
  • Leiser Betrieb: Airflow ventilation and impeller design minimize noise.
  • Haltbarkeit: IP55 waterproof rating and heat-resistant sealing for extended motor lifespan.
Oswerpon 2HP Pool Pump showing max flow, speed, and head

Figure 2: Performance metrics of the 2HP Oswerpon Pool Pump, highlighting maximum flow, speed, and head.

Diagram of 2HP Dual-Voltage Motor with features like low noise, self priming, high pressure, and overheat protection

Abbildung 3: Intern view of the 2HP dual-voltage motor, emphasizing its low noise, self-priming, high-pressure, and overheat protection capabilities.

Labeled diagram of Oswerpon Pool Pump components

Figure 4: Detailed product description with labeled components including Filter Basket, Inlet, Outlet, Earthing Terminal, Pure Copper Motor, Voltage Switch Button, Drain Plug, Pipe Fittings, and Sealing Tape.

Setup und Installation

The Oswerpon pool pump is designed for easy installation. It comes with all necessary accessories for various pipe sizes.

Mitgeliefertes Zubehör:

  • 2 x 1.5-inch connectors
  • 2 x 2-inch adapters
  • 2 x 1.25-1.5-inch fittings
  • Dichtungsband
Image showing various universal fittings for the pool pump

Figure 5: Universal fittings included for pipe and hose connections (1-1.25 inch, 1.5 inch, 2 inch).

Verbindungsmethoden:

You can connect the pump using PVC pipe glue or PVC hose with clamps.

Diagram showing two methods for pump outlet/inlet connection: PVC Pipe Glue and PVC Hose with Clamp

Figure 6: Two common methods for connecting the pump's inlet and outlet: direct PVC pipe glue connection or PVC hose with clamp.

Bandtage Auswahl:

This pump supports dual voltage (115V/230V). Use the integrated voltage adjustment button to select the appropriate voltage für Ihr Setup.

Abbildung, die die zwei Lautstärkeregler zeigttage switch on the pump, allowing selection between 115V and 230V

Abbildung 7: Das Volumentage switch button on the pump, enabling effortless toggling between 115V and 230V.

Installationsvideo:

Video 1: Endeview of the Oswerpon 2 HP/1.5 HP Self Priming in/above ground Pool Pump, demonstrating its features and general setup.

Bedienungsanleitung

  1. Vorbereiten der Pumpe: Before first use and after any maintenance that drains the pump, ensure the pump is filled with water. Open the transparent lid, fill the strainer basket housing with water, and then securely close the lid.
  2. Einschalten: Connect the pump to the appropriate power supply (115V or 230V) after confirming the voltage-Schaltereinstellung.
  3. Monitorbetrieb: The pump will begin circulating water. Observe the transparent lid to ensure continuous water flow and no air bubbles, indicating proper priming.
  4. Dauerbetrieb: The pump is designed for continuous operation to maintain pool water quality.

Video 2: Demonstrates the Oswerpon Pool Pump in operation for both above-ground and in-ground pools, showcasing its quiet and efficient performance.

Wartung

Regular maintenance ensures the longevity and optimal performance of your Oswerpon pool pump.

Strainer Basket Cleaning:

The oversized filter basket is designed for easy cleaning. Regularly inspect the transparent cover for debris accumulation.

  1. Pumpe ausschalten und Stromzufuhr unterbrechen.
  2. Unscrew the transparent lid counter-clockwise.
  3. Remove the strainer basket and empty any collected debris (leaves, hair, grit, etc.).
  4. Spülen Sie den Korb gründlich mit Wasser aus.
  5. Place the clean basket back into the pump housing.
  6. Fill the housing with water to prime the pump.
  7. Securely fasten the transparent lid by turning clockwise.
  8. Reconnect power and restart the pump.
Oversized filter basket removed from the pump, with leaves and debris around it

Figure 8: The extra-large filter basket, designed to capture leaves, grit, branches, and hair, shown removed for cleaning.

Close-up of the pump's transparent lid with 'CLOSE' and 'OPEN' indicators

Figure 9: The transparent lid allows for easy visual inspection of the filter basket and quick removal of debris.

Fehlerbehebung

ProblemMögliche UrsacheLösung
Pumpe startet nichtNo power; incorrect voltage setting; motor overload.Check power connection and circuit breaker. Verify voltage switch (115V/230V). Allow motor to cool if overheated.
Pumpe läuft, aber kein WasserflussPump not primed; clogged strainer basket; air leak in suction line.Fill pump with water (prime). Clean strainer basket. Check all connections for air leaks.
Reduzierter WasserdurchflussClogged strainer basket; dirty filter; low water level in pool.Clean strainer basket. Clean or backwash pool filter. Ensure adequate pool water level.
Übermäßiger Lärm/VibrationenAir in pump/lines; loose mounting; debris in impeller.Prime pump thoroughly. Tighten mounting bolts. Inspect impeller for debris (power off first).

Technische Daten

AttributDetail
MarkeOswerpon
ModellnummerHBP1500II(230V)
PS2 PS
Bandtage115 V/230 V (Dual Vol)tage)
Maximaler Durchfluss67.37 GPM (6900 GPH)
Maximale Hubhöhe (Kopf)55.7 Fuß
Technische Daten22.4 Zoll L x 9.8 Zoll B x 11.4 Zoll H
Artikelgewicht32 Pfund
MaterialEdelstahl, Kunststoff
Spezifische VerwendungenIn/Above-Ground Pool, Hot Tubs, Spas, Hydrotherapy, Irrigation Systems (not for storage tanks)
Maximale Wassertemperatur104°F (40°C)
WasserdichtigkeitIP55
Product dimensions and universal fittings

Figure 10: Physical dimensions of the pump and a visual representation of the universal fittings.

Pool Sizing Guide:

The Oswerpon 2HP pump is suitable for a wide range of pool sizes. Refer to the charts below for recommended pool types and capacities.

Chart for Round Pool sizing recommendations based on HP

Figure 11: Recommended Oswerpon pump horsepower for various round pool sizes and gallon capacities.

Chart for Square Pool sizing recommendations based on HP

Figure 12: Recommended Oswerpon pump horsepower for various square pool sizes and gallon capacities.

Chart for Oval Pool sizing recommendations based on HP

Figure 13: Recommended Oswerpon pump horsepower for various oval pool sizes and gallon capacities.

Chart for Kidney Pool sizing recommendations based on HP

Figure 14: Recommended Oswerpon pump horsepower for various kidney-shaped pool sizes and gallon capacities.

Garantie und Support

For warranty information and technical support, please contact Oswerpon customer service. Keep your purchase receipt and product model number handy for faster service.

Weitere Informationen finden Sie auch im Benutzerhandbuch (PDF) für weitere Einzelheiten.

Ask a question about this manual