1. Produktüberschreitungview
The OONO D-1437 is a 2-channel power distribution module featuring rocker switch thermal circuit breaker overload protectors. Designed for DIN rail mounting, this module provides protection against overcurrent conditions for electrical circuits. Each channel includes a 10A thermal circuit breaker, allowing manual control of the output state (RESET or OFF) and indicating normal operation with a built-in red light.
2. Hauptmerkmale
- Eingangslautstärketage: AC 125V to 250V, 50-60Hz.
- Maximum Total Input Current: 20A (per position terminal block).
- Maximaler Ausgangsstrom: 10A per channel.
- Maximum Total Output Current: 20A.
- Leistungsschalter: Two 10A rocker switch thermal circuit breaker overload protectors.
- Schalterfunktionalität: Manual RESET or OFF states with integrated red indicator light for normal output.
- Klemmenblöcke: Pitch 7.62mm (0.3 inch), suitable for 26AWG to 10AWG (4.0mm square) wires.
- DIN-Schienenmontage: High-quality fireproof nylon material carrier, compatible with 35mm, 32mm, and 15mm DIN rails.
- Konstruktion: FR-4 fiberglass dual copper layers PCB.
3. Technische Daten
| Spezifikation | Wert |
|---|---|
| Marke | Oono |
| Modell | D-1437 |
| Eingangslautstärketage | Wechselstrom 125 – 250 V, 50/60 Hz |
| Maximaler Gesamteingangsstrom | 20 A |
| Maximaler Ausgangsstrom (pro Kanal) | 10 A |
| Maximaler Gesamtausgangsstrom | 20 A |
| Leistungsschaltertyp | Thermal, Rocker Switch |
| Anzahl der Pole | 2 |
| Montagetyp | DIN-Schienenmontage |
| Klemmenblock-Raster | 7.62 mm (0.3 Zoll) |
| Drahtbereich | 26AWG to 10AWG (4.0mm²) |
| Streifenlänge | 8 mm |
| Schraubenmaterial | M3, Steel, Cr3+ Zn plated |
| Pin Header and Cage Material | Messing |
| PCB-Material | FR-4 Glasfaser-Doppelkupferschichten |
4. Sicherheitshinweise
WARNUNG: Electrical shock hazard. Installation and servicing should only be performed by qualified personnel. Always disconnect power at the main circuit breaker or fuse box before installing or servicing this device.
- Stellen Sie sicher, dass alle Verkabelungen den lokalen und nationalen Elektrovorschriften entsprechen.
- Überschreiten Sie nicht das angegebene Volumentage und aktuelle Nennwerte des Geräts.
- Verify proper wire gauge for the current load to prevent overheating.
- Ensure secure connections at all terminal blocks to prevent loose contacts and potential hazards.
- Dieses Gerät ist für den Gebrauch in Innenräumen in trockenen Umgebungen konzipiert. Vermeiden Sie den Kontakt mit Feuchtigkeit oder extremen Temperaturen.
5. Einrichtung und Installation
5.1 DIN-Schienenmontage
The OONO D-1437 module is designed for easy installation on standard DIN rails (35mm, 32mm, or 15mm width). To mount, align the module's clips with the DIN rail and press firmly until it snaps into place. To remove, gently pull the release mechanism (if present) or pry the module off the rail.

5.2 Kabelverbindungen
Refer to the schematic and connection diagrams for proper wiring. Ensure power is disconnected before making any connections.
- Eingangsklemmen: Connect the AC 125-250V power supply to the input terminals labeled 'N' (Neutral) and 'L' (Line). The module supports a maximum total input current of 20A.
- Ausgangsklemmen: Each channel has 'L' and 'N' output terminals. Connect your load to the corresponding output channel. Each channel supports a maximum output current of 10A. The maximum total output current for the module is 20A.
- Kabelspezifikationen: Use wires within the range of 26AWG to 10AWG (4.0mm²). Strip wire insulation approximately 8mm before inserting into the terminal blocks. Tighten M3 screws securely.




5.3 Abmessungen
For precise integration into your electrical panel, refer to the detailed dimensional drawing below.

5.4 Installation überview Video
Watch this video for a visual guide on the product's features and installation process.
6. Bedienungsanleitung
The OONO D-1437 features two independent rocker switches, each controlling one output channel.
- ON/RESET Position: When the rocker switch is pressed to the 'RESET' side, the circuit breaker is closed, allowing power to flow to the connected load. A built-in red indicator light will illuminate when the output is normal.
- AUS-Position: When the rocker switch is pressed to the 'OFF' side, the circuit breaker is open, disconnecting power to the connected load. The red indicator light will be off.
- Überlastschutz: In the event of an overcurrent, the thermal circuit breaker will automatically trip, moving the rocker switch to the 'OFF' position and disconnecting the load to prevent damage. To reset after an overload, allow a brief cooling period, then manually press the switch to the 'RESET' position. If the breaker trips repeatedly, investigate the cause of the overload.
7. Wartung
The OONO D-1437 is designed for minimal maintenance. However, periodic inspection is recommended to ensure optimal performance and safety.
- Reinigung: Ensure the module is free from dust and debris. Use a dry, soft cloth for cleaning. Do not use liquid cleaners or solvents.
- Verbindungsprüfung: Periodically inspect all wire connections to ensure they remain tight and secure. Loose connections can lead to overheating or intermittent operation.
- Sichtprüfung: Check for any signs of physical damage, discoloration, or burning on the module or wiring. Replace the unit immediately if any damage is observed.
8. Fehlerbehebung
- Keine Stromversorgung:
- Check if the rocker switch is in the 'RESET' position.
- Verify that the input power supply is active.
- Überprüfen Sie alle Kabelverbindungen auf Lockerheit oder Beschädigung.
- Circuit Breaker Trips Repeatedly:
- This indicates an overcurrent condition. Disconnect the load and check for short circuits or excessive current draw.
- Ensure the connected load does not exceed the 10A rating of the individual channel or the 20A total rating of the module.
- Allow the breaker to cool down before attempting to reset.
- Kontrollleuchte leuchtet nicht:
- The indicator light illuminates when the output is normal and the switch is in the 'RESET' position. If it's off, check the switch position, input power, and load connection.
- If the breaker has tripped, the light will be off.
9. Garantie und Support
Informationen zu Garantie und technischem Support finden Sie in der mitgelieferten Dokumentation oder wenden Sie sich direkt an den Hersteller. Bewahren Sie Ihren Kaufbeleg als Kaufnachweis auf.