UMLIFE STC-1000 12V

UMLIFE STC-1000 10A DC 12V Digital LED Temperature Controller User Manual

1. Einleitung

The UMLIFE STC-1000 is a versatile digital temperature controller designed for precise temperature management in various applications. This device features a clear LED display, NTC 10K thermistor sensor, and dual relay outputs for both heating and cooling control. This manual provides detailed instructions for installation, operation, and maintenance to ensure optimal performance and longevity of your temperature controller.

2. Produktüberschreitungview

2.1 Hauptmerkmale

  • Digital LED display for clear temperature readings.
  • Wide temperature measurement and control range: -50°C to 99°C.
  • High control accuracy of 0.1°C.
  • Dual relay output for simultaneous heating and cooling control.
  • Waterproof NTC 10K thermistor sensor for reliable measurements in various environments.
  • Temperaturkalibrierungsfunktion.
  • Delay start protection for cooling control.
  • ABS flame-retardant shell for enhanced safety.

2.2 Komponenten und Anzeige

Familiarize yourself with the main components and display interface of the STC-1000 controller.

UMLIFE STC-1000 Front Panel with Labels

Abbildung 1: Front panel of the STC-1000 controller showing the digital display, power switch, UP button, Setting button, and DOWN button.

  • Digitales Anzeigefenster: Zeigt die aktuelle Temperatur und die Parametereinstellungen an.
  • Stromschalter: Schaltet das Gerät ein oder aus.
  • Aufwärts-Taste (▲): Erhöht Werte oder navigiert durch Menüs.
  • AB-Taste (▼): Verringert Werte oder navigiert durch Menüs.
  • Setting Button (S): Wechselt in den Parametereinstellungsmodus.
  • Cool-Indikator: Illuminates when cooling relay is active.
  • Wärmeanzeige: Illuminates when heating relay is active.
UMLIFE STC-1000 Dimensions and Sensor

Abbildung 2: Physical dimensions of the STC-1000 controller and the included 1-meter NTC 10K waterproof sensor probe.

3. Spezifikationen

ParameterWert
ModellSTC-1000
Temperaturmessbereich-50°C bis 99°C
Temperaturregelbereich-50°C bis 110°C
Messgenauigkeit±0.2 °C
Auflösung0.1°C
Kontrollgenauigkeit±0.1 °C
SensorNTC 10K L=1M waterproof probe
StromversorgungGleichstrom 12 V
Energieaufnahme<3 W
RelaiskontaktkapazitätCool (10A/220VAC), Heat (10A/220VAC)
Umgebungstemperatur0°C bis 60°C
Lagertemperatur-30°C bis 75°C
Relative Luftfeuchtigkeit20-84 %
Montagegröße71mm x 29mm
Technische Daten75 mm x 34.5 mm x 85 mm
Artikelgewicht7 Unzen (ca. 198 g)
MaterialAcrylnitril-Butadien-Styrol (ABS)

4. Einrichtung und Installation

Wichtiger Sicherheitshinweis: Installation should be performed by qualified personnel. Ensure power is disconnected before wiring to prevent electric shock. Strictly distinguish between power supply, sensor, and relay interfaces. Maintain proper distance between sensor down-lead and power wires to avoid interference.

4.1 Schaltplan

Refer to the following diagram for correct wiring connections. This model operates on DC 12V power supply.

UMLIFE STC-1000 Wiring Diagram

Abbildung 3: Wiring diagram for the STC-1000 12V temperature controller. Connections are for power supply, NTC sensor, heating relay, and cooling relay.

  • Terminals 1 & 2: Power Supply (DC 12V).
  • Terminals 3 & 4: NTC Sensor connection.
  • Terminals 5 & 6: Heating Relay Output (Connect to heating device).
  • Terminals 7 & 8: Cooling Relay Output (Connect to cooling device).

Ensure all connections are secure and insulated. Verify the power supply voltage matches the controller's requirement (DC 12V for this model).

4.2 Montage

The STC-1000 is designed for panel mounting. Cut an opening of 71mm x 29mm in your panel. Insert the controller and secure it using the provided clips or mounting brackets.

5. Bedienungsanleitung

The STC-1000 operates in Celsius only. It cannot be switched to Fahrenheit.

5.1 Ein-/Ausschalten

  • Drücken Sie die Netzschalter button (marked with ) um den Controller ein- oder auszuschalten.

5.2 Einstellen der Temperaturparameter

The controller has two main temperature settings: the Set Temperature (ST) und die Difference Temperature (DT), also known as hysteresis.

  1. Zu view the Set Temperature (ST): Drücken Sie kurz die Setting (S) button. The display will show the current set temperature.
  2. To modify the Set Temperature (ST):
    • Halten Sie die Setting (S) button for approximately 3 seconds until the display flashes.
    • Verwenden Sie die AUF (▲) or UNTEN (▼) buttons to adjust the desired set temperature.
    • Drücken Sie die Netzschalter button to save the setting and exit, or wait for 10 seconds for it to save automatically.

5.3 Advanced Parameter Settings (F1-F4)

So greifen Sie auf erweiterte Parameter zu und ändern diese:

  1. Halten Sie die Setting (S) button for approximately 3 seconds until the display flashes.
  2. Während die Anzeige blinkt, drücken Sie die Taste Setting (S) button again (do not hold) to cycle through parameters F1, F2, F3, F4.
  3. Verwenden Sie die AUF (▲) or UNTEN (▼) Schaltflächen zum Anpassen des Wertes des ausgewählten Parameters.
  4. Drücken Sie die Netzschalter button to save the setting and exit, or wait for 10 seconds for it to save automatically.
ParameterBeschreibungReichweiteStandard
F1Difference Temperature (Hysteresis): The difference between the set temperature and the temperature at which the relay switches off.0.3°C bis 10°C2.0°C
F2Highest Set Point Limit: Limits the maximum adjustable set temperature.Set Temp to 110°C110°C
F3Lowest Set Point Limit: Limits the minimum adjustable set temperature.-50°C to Set Temp-50°C
F4Temperaturkalibrierung: Adjusts the temperature reading to match a known accurate thermometer.-10°C bis 10°C0.0°C

5.4 Heiz- und Kühlmodi

The STC-1000 automatically switches between heating and cooling based on the set temperature (ST) and difference temperature (DT).

  • Kühlmodus: If the current temperature is higher than (ST + DT), the cooling relay activates. It deactivates when the temperature drops to ST.
  • Heizbetrieb: If the current temperature is lower than (ST - DT), the heating relay activates. It deactivates when the temperature rises to ST.

6. Wartung

  • Reinigung: Wischen Sie die Oberfläche des Controllers mit einem weichen, trockenen Tuch ab. Verwenden Sie keine Scheuermittel oder Lösungsmittel.
  • Sensorpflege: Ensure the NTC sensor probe is clean and free from debris. While waterproof, avoid unnecessary physical damage to the probe or cable.
  • Verbindungen: Periodically check wiring connections for tightness and signs of corrosion.
  • Umfeld: Operate the controller within the specified ambient temperature and humidity ranges to ensure optimal performance and lifespan.

7. Fehlerbehebung

ProblemMögliche UrsacheLösung
Display shows "EE"Sensorfehler oder offener Stromkreis.Prüfen Sie den Sensoranschluss. Ersetzen Sie den Sensor, falls er beschädigt ist.
Display shows "HHH"Temperature exceeds upper limit of measurement range.Ensure the environment temperature is within the sensor's range (-50°C to 99°C).
Display shows "LLL"Temperature falls below lower limit of measurement range.Ensure the environment temperature is within the sensor's range (-50°C to 99°C).
Controller lässt sich nicht einschaltenKeine Stromversorgung oder falsche Lautstärketage.Check power connections and ensure DC 12V is supplied.
Heizung/Kühlung aktiviert sich nichtIncorrect temperature settings (ST, DT), wiring error, or device malfunction.Verify ST and DT settings. Check heating/cooling device wiring. Ensure the device is within operating parameters.

8. Garantie und Support

UMLIFE products are manufactured to high-quality standards. For warranty information or technical support, please contact UMLIFE customer service through your purchase platform or visit the official UMLIFE website. Please have your product model (STC-1000 12V) and purchase details ready when contacting support.

Für weitere Unterstützung können Sie sich auch an die folgende Stelle wenden: UMLIFE Store on Amazon.

© 2023 UMLIFE. Alle Rechte vorbehalten.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.