AmScope B120C-DK-E1

AmScope B120C-DK-E1 Binocular LED Darkfield Microscope User Manual

Model: B120C-DK-E1

Einführung

This manual provides instructions for the proper setup, operation, and maintenance of your AmScope B120C-DK-E1 Binocular LED Darkfield Microscope. This instrument is designed for educational, clinical, and laboratory applications, offering both brightfield and darkfield observation capabilities. Please read this manual thoroughly before using the microscope to ensure safe and effective operation.

Sicherheitshinweise

  • Always handle the microscope with care. Avoid sudden movements or impacts.
  • Stellen Sie sicher, dass das Mikroskop auf einer stabilen, ebenen Fläche steht, um ein Umkippen zu verhindern.
  • Vor der Reinigung oder Durchführung von Wartungsarbeiten den Netzstecker ziehen.
  • Do not expose the microscope to direct sunlight, high temperatures, or high humidity.
  • Verwenden Sie ausschließlich das angegebene Netzteil.
  • Keep the optical components clean. Avoid touching lenses with bare hands.
  • Do not attempt to disassemble or repair the microscope yourself. Contact qualified service personnel.

Komponenten und Funktionen

Familiarize yourself with the main components of your AmScope B120C-DK-E1 microscope:

AmScope B120C-DK-E1 Microscope with labeled features

Abbildung 1: Überview of the AmScope B120C-DK-E1 Binocular Compound Microscope, highlighting key features such as the 2-layer mechanical stage, 360-degree adjustable head, 40X-2500X magnification, coaxial coarse and fine focus, and LED sub-stage Beleuchtung.

Siedentopf Binocular Head with 360-degree rotation

Abbildung 2: The Siedentopf binocular head, featuring 360-degree rotation and a 30-degree inclination for comfortable viewing and posture adjustment.

Mechanisch Stage and Focus Knobs

Abbildung 3: Detaillierte view of the 2-layer mechanical stage and the coaxial coarse and fine focus knobs, designed for precise specimen movement and focusing.

LED Transmitted Illumination System

Abbildung 4: The LED sub-stage lighting system, providing cool, energy-efficient, and daylight-balanced illumination for improved contrast and resolution.

Schlüsselkomponenten:

  • Siedentopf Binocular Head: Rotates 360 degrees with a 30-degree inclination for ergonomic viewing.
  • Okulare: Includes 10X and 25X widefield eyepieces for various magnification levels.
  • Objektivlinsen: Achromatic, color-coded objective lenses (e.g., 4X, 10X, 40X, 100X oil) mounted on a revolving nosepiece.
  • Mechanisch Stage: A 2-layer stage with low-position controls for precise X-Y movement of slides.
  • Coaxial Focus Knobs: Separate coarse and fine focus adjustments for accurate focusing.
  • LED Illuminator: Untertage LED light source with adjustable brightness.
  • Kondensator: Includes a brightfield condenser and a darkfield condenser for specialized observation.
  • 1MP Digital Eyepiece Camera: For capturing images and videos, compatible with Windows, Mac, and Linux.

Aufstellen

  1. Auspacken: Nehmen Sie alle Komponenten vorsichtig aus der Verpackung. Bewahren Sie die Verpackung für späteren Transport oder Lagerung auf.
  2. Platzierung: Stellen Sie das Mikroskop auf eine stabile, vibrationsfreie Oberfläche, fern von direkter Sonneneinstrahlung und Wärmequellen.
  3. Kopfmontage: Loosen the head retaining screw on the top of the microscope body. Gently insert the binocular head into the opening, ensuring it is fully seated. Tighten the retaining screw.
  4. Okularmontage: Remove the protective caps from the eyepiece tubes. Insert the desired eyepieces (10X or 25X) into the tubes.
  5. Objective Lens Installation: Rotate the revolving nosepiece to ensure there is no objective lens directly above the stage. Screw the objective lenses into the nosepiece in increasing order of magnification (e.g., 4X, 10X, 40X, 100X).
  6. Stromanschluss: Connect the power cord to the microscope's power input and then to a suitable electrical outlet.
  7. Digital Eyepiece Camera Installation: If using the digital eyepiece, remove one of the standard eyepieces and insert the 1MP digital eyepiece camera into the eyepiece tube. Connect the camera to your computer via USB.

Bedienungsanleitung

1. Brightfield Observation

Microscope objective lenses and magnification examples

Abbildung 5: Examples of magnification levels (10X, 100X, 400X, 1000X) achievable with the AmScope B120C-DK-E1, utilizing various objective lenses and eyepieces, including the additional 25X eyepieces for up to 2500X magnification.

  1. Einschalten: Turn on the main power switch. Adjust the LED illuminator brightness using the dimmer control.
  2. Stage-Einstellung: Senken Sie die mechanische stage using the coarse focus knob to create enough space to place a slide.
  3. Slide Placement: Place a prepared specimen slide onto the mechanical stage, es mit dem s zu sicherntage clips. Use the X-Y stage controls to position the specimen over the light aperture.
  4. Vergrößerungsauswahl: Rotate the revolving nosepiece to select the lowest power objective lens (e.g., 4X). Ensure it clicks into place.
  5. Fokussierung:
    • Während Sie durch die Okulare schauen, heben Sie langsam den Kopf an.tage using the coarse focus knob until the specimen comes into rough focus.
    • Use the fine focus knob to achieve sharp focus.
    • Adjust the interpupillary distance (distance between eyepieces) and diopter adjustment on the eyepiece for comfortable viewing and to correct for differences in vision between your eyes.
  6. Erhöhungasing Magnification: Once focused at low power, rotate the nosepiece to a higher power objective (e.g., 10X, 40X). The microscope is parfocal, meaning only minor adjustments with the fine focus knob should be needed.
  7. Using 100X Oil Immersion Objective:
    • After focusing with the 40X objective, rotate the nosepiece halfway between the 40X and 100X objectives.
    • Geben Sie einen kleinen Tropfen Immersionsöl direkt in die Mitte des Objektträgers.
    • Rotate the 100X objective into the oil drop. The objective lens should make contact with the oil.
    • Use only the fine focus knob to bring the image into sharp focus. Do not use the coarse focus knob with the 100X objective.
    • After use, clean the 100X objective lens and the slide immediately with lens cleaning solution and lens paper.
  8. Kondensatoreinstellung: Adjust the iris diaphragm on the condenser to control the amount of light and contrast. For higher magnifications, open the diaphragm more. For lower magnifications, close it slightly. The condenser can also be centered for optimal illumination.

2. Darkfield Observation

The AmScope B120C-DK-E1 includes a darkfield condenser for observing unstained, live specimens.

  1. Condenser Exchange: Remove the brightfield condenser from its mount beneath the stage. Carefully insert the darkfield condenser into the mount. Ensure it is seated correctly.
  2. Probenvorbereitung: Darkfield observation works best with thin, unstained specimens.
  3. Beleuchtung: Turn on the LED illuminator and set it to a high brightness level.
  4. Fokussierung: Use a low power objective (e.g., 10X or 20X, if available) first. Focus on the specimen as you would in brightfield. The specimen will appear brightly lit against a dark background.
  5. Centering the Darkfield Condenser: Some darkfield condensers require centering. If your condenser has centering screws, adjust them until the darkfield effect is uniform across the field of view.
  6. Höhere Vergrößerung: For higher magnifications, you may need to use a specialized darkfield objective or ensure your standard objectives are compatible. Always ensure sufficient immersion oil is used with 100X darkfield objectives.

3. Digital Eyepiece Camera Operation

The included 1MP digital eyepiece camera allows for image capture and live viewauf einem Computer.

Microscope connected to laptop with digital image

Abbildung 6: The AmScope B120C-DK-E1 microscope connected to a laptop, demonstrating live digital viewing and image capture capabilities via the 1MP digital eyepiece camera.

  1. Softwareinstallation: Install the professional microscopy software provided (or download the latest version from the AmScope website) onto your Windows, Mac, or Linux computer.
  2. Kamera anschließen: Insert the digital eyepiece camera into one of the microscope's eyepiece tubes and connect it to your computer via the USB cable.
  3. Software starten: Open the installed microscopy software. The software should detect the camera automatically.
  4. Live View: The software will display a live feed from the microscope. Adjust microscope focus and illumination for the best image.
  5. Bild-/Videoaufnahme: Use the software's functions to capture still images or record videos of your observations. The software also provides tools for image processing and measurement.

Wartung

  • Linsenreinigung: Use a soft brush to remove dust from lens surfaces. For smudges or oil, use a small amount of lens cleaning solution on lens paper. Wipe gently in a circular motion. Never use abrasive cloths or harsh chemicals.
  • Reinigung des Körpers: Wischen Sie das Mikroskopgehäuse mit einem weichen, fusselfreien Tuch ab.amp Tuch. Vermeiden Sie, dass Feuchtigkeit in elektrische Bauteile gelangt.
  • Lagerung: Wenn das Mikroskop nicht in Gebrauch ist, decken Sie es mit einer Staubschutzhülle ab, um es vor Staub und Schmutz zu schützen. Bewahren Sie es an einem kühlen, trockenen Ort auf.
  • Immersionsöl: Always clean immersion oil from the 100X objective and slides immediately after use. Dried oil can be difficult to remove and can damage the lens.

Fehlerbehebung

Problem Mögliche Ursache Lösung
Keine Beleuchtung Power cord disconnected, power switch off, dimmer set to minimum, LED bulb failure. Check power connections, turn on switch, adjust dimmer, contact support if LED is faulty.
Bild unscharf/verschwommen Incorrect focus, objective lens dirty, eyepiece dirty, slide upside down, condenser not adjusted. Adjust coarse/fine focus, clean lenses, ensure slide is correct side up, adjust condenser/diaphragm.
Dunkle Flecken im Feld view Staub auf Okular, Objektiv oder Objektträger. Clean eyepieces, objectives, and slides. Rotate eyepiece to determine if dust is on eyepiece.
No darkfield effect Incorrect condenser, condenser not centered, illumination too low. Ensure darkfield condenser is installed, center the condenser, increase illumination brightness.
Digitalkamera nicht erkannt USB cable disconnected, software not installed, driver issue. Check USB connection, install software/drivers, restart computer.

Technische Daten

Modell B120C-DK-E1
Kopf Siedentopf Binocular, 360° Rotatable, 30° Inclined
Okulare WF10X, WF25X
Objektive Achromatic 4X, 10X, 40X (Spring), 100X (Spring, Oil)
Gesamtvergrößerung 40- bis 2500-fach
Nasenstück Revolving Quadruple
Stage 2-Layer Mechanical Stage with X-Y Scale
Fokussierung Coaxial Coarse & Fine Adjustment
Beleuchtung LED Transmitted Light with Dimmer
Kondensator Abbe NA1.25 (Brightfield), Darkfield Condenser
Digitalkamera 1MP USB Digital Eyepiece Camera
Stromquelle Kabelgebundene Elektrik
Material Metall
Farbe Weiß

Garantie und Support

The AmScope B120C-DK-E1 microscope comes with a 5 Jahr Herstellergarantie. For warranty claims, technical support, or service inquiries, please contact AmScope customer service directly.

For additional resources, software downloads, and frequently asked questions, please visit the official AmScope webWebsite:

www.amscope.com