FIERRG KVP8 PLUS-KK-S

FIERRG KVP8 Mini Diaphragm Pump KVP8 PLUS-KK-S

Bedienungsanleitung

1. Produktüberschreitungview

The FIERRG KVP8 Mini Diaphragm Pump, model KVP8 PLUS-KK-S, is a compact and efficient pump designed for various applications requiring precise gas or air handling. This pump features a durable motor and is engineered for smooth operation with low noise output.

Zu den Hauptmerkmalen gehören:

  • Negative Pressure: < -0.082Mpa
  • Positive Pressure: > 0.1Mpa
  • Available with Brush or Brushless motor options.
  • Lightweight design, weighing less than 0.3 KG.
  • Engineered for long working life and high efficiency.
  • Compact size for easy integration and use.

2. Spezifikationen

Detailed technical specifications for the KVP8 PLUS-KK-S model are provided below:

Technical specifications table for KVP8 PLUS-KK-S pump

Image: Technical specifications including voltage, power, pressure, and flow rate for the KVP8 PLUS-KK-S pump.

KVP8 PLUS-KK-S Technical Data
ParameterWert
ModellKVP8 PLUS-KK-S
Bandtage Bewertung12 V / 24 V
Leistung9W
Positiver Druck> 0.12Mpa
Negativer Druck< -0.09Mpa
Durchflussrate> 380L/H (for KVP8 PLUS-KK-S)
Flow Rate Range (Parallel/Series)380~660L/H
Geräuschpegel< 65 dB
GewichtLess than 0.3 KG (0.66 lbs)
Abmessungen (ungefähr)76.2 mm (Länge) x 31 mm (Breite) x 31 mm (Höhe)
Dimensions of the KVP8 PLUS-KJ-S pump

Abbildung: Seite view of the pump showing approximate dimensions of 76.2mm in length and 31mm in width/height.

3. Einrichtung und Installation

Proper installation ensures optimal performance and longevity of your pump. Follow these guidelines for setup:

  1. Montage: The pump is designed for secure mounting using three designated holes. Ensure the mounting surface is stable and flat.
  2. Installation points for the KVP8 PLUS-KJ-S pump

    Bild: Vorderseite view of the pump highlighting the three installation holes for mounting.

  3. Verbindungen: Identify the "IMPORT" (inlet) and "EXPORT" (outlet) ports on the pump. Connect tubing securely to prevent leaks.
  4. Import and Export ports on the KVP8 pump

    Abbildung: Seite view of the pump indicating the "IMPORT" and "EXPORT" ports for tubing connections.

  5. Stromversorgung: Connect the pump to a 12V or 24V DC power source, matching the pump's voltage rating. Ensure correct polarity.

4. Bedienungsanleitung

The KVP8 Mini Diaphragm Pump can be configured for different flow rates depending on the connection method:

  • Reihenschaltung: For higher pressure applications.
  • Parallele Verbindung: For higher flow rate applications.
Diagram showing parallel and series connections for different air flow rates

Image: Comparison of two pump configurations: "In Parallel" and "In Series," illustrating how different connections achieve a flow rate range of 380~660 L/H.

Once connected to the power supply and tubing, the pump will operate. Monitor the system for proper function and ensure all connections remain secure.

5. Wartung

To ensure the longevity and reliable performance of your FIERRG KVP8 Mini Diaphragm Pump, consider the following maintenance tips:

  • Regelmäßige Inspektion: Periodically check all tubing and connections for signs of wear, cracks, or leaks. Replace any damaged components immediately.
  • Sauber halten: Ensure the pump's exterior is free from dust and debris. Avoid introducing foreign particles into the inlet or outlet ports.
  • Lagerung: When not in use for extended periods, store the pump in a clean, dry environment away from extreme temperatures.

6. Fehlerbehebung

If you encounter issues with your pump, refer to these common troubleshooting steps:

  • Pumpe startet nicht:
    • Check power connections and ensure the power supply is active and providing the correct voltage (12 V oder 24 V).
    • Prüfen Sie, ob die korrekte Polarität des Stromanschlusses vorliegt.
  • Low Flow/Pressure:
    • Inspect tubing for kinks, blockages, or leaks.
    • Ensure inlet and outlet ports are clear.
    • Confirm the pump is configured correctly for the desired flow/pressure (series vs. parallel).
  • Ungewöhnliches Geräusch:
    • Prüfen Sie, ob die Befestigungsschrauben locker sind.
    • Ensure no foreign objects are obstructing the pump's operation.

Sollten die Probleme nach Durchführung dieser Schritte weiterhin bestehen, wenden Sie sich bitte an den Kundendienst, um weitere Unterstützung zu erhalten.

7. Typische Anwendungen

The versatility of the KVP8 Mini Diaphragm Pump makes it suitable for a range of applications, including but not limited to:

  • Gas Analysis Systems
  • Mounter Equipment
  • Physiotherapy Devices
  • Beauty Industry Equipment
Examples of applications for the KVP8 pump: Gas Analysis, Mounter, Physiotherapy, Beauty Industry

Image: Collage showing various industrial and medical settings where the KVP8 pump can be utilized, such as gas analysis, mounter machines, physiotherapy, and beauty equipment.

8. Garantie und Support

For warranty information or technical support, please refer to the product packaging or contact your retailer. FIERRG is committed to providing customer satisfaction and assistance with product-related inquiries.

The manufacturer states a commitment to pursuing the highest quality and offering timely customer service, dedicated to providing a 100% satisfaction solution for any concerns.

© 2023 FIERRG. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.