1. Einleitung
The TAXNELE THC30A is a digital electronic timer switch designed for automated control of various electrical equipment. It features daily and weekly programming capabilities, allowing for up to 20 ON/OFF settings. This device is suitable for DIN rail mounting and includes a 3V Lithium battery for power reserve, ensuring time and program data are maintained during power interruptions.
2. Produktmerkmale
- Programmierbare Steuerung: Up to 20 ON/OFF settings per day or week.
- Manuelle Übersteuerung: Allows for temporary manual control (ON/AUTO/OFF).
- Ausschaltspeicher: Built-in 3V Lithium battery (CR2032) maintains timing, display, and program data for up to 3 years during power outages.
- Hohe Präzision: Industrial-grade chip for accurate timing.
- LCD Anzeige: Clear digital display for easy programming and monitoring.
- DIN-Schienenmontage: Designed for easy installation on standard DIN rails.
- Breite Anwendung: Suitable for street lights, neon lamps, advertising signs, production equipment, broadcast devices, and other power control applications.

Bild 2.1: The THC30A timer features a power-off memory function, supported by an internal CR2032 lithium battery, which retains settings and time for extended periods without external power.
3. Sicherheitshinweise
Bitte lesen und verstehen Sie alle Sicherheitshinweise vor der Installation und Inbetriebnahme. Die Nichtbeachtung dieser Hinweise kann zu Stromschlag, Brand oder schweren Verletzungen führen.
- Always disconnect power at the circuit breaker or fuse box before installing or servicing the timer switch.
- Die Installation sollte von einem qualifizierten Elektriker oder einer sachkundigen Person durchgeführt werden.
- Stellen Sie sicher, dass die LautstärketagDie Nennwerte und die Stromstärke des Timers entsprechen den Anforderungen Ihrer Anwendung.
- Die maximale Belastbarkeit von 30 A bzw. 5000 W darf nicht überschritten werden.
- Nicht bei Nässe oder damp environments unless specifically rated for such conditions.
- Halten Sie Kinder von elektrischen Geräten fern.
4. Einrichtung
4.1 Schaltplan
The THC30A timer is designed for easy wiring. Connect the input power (Live 'L' and Neutral 'N') to the 'IN' terminals and the load (e.g., light, appliance) to the 'OUT' terminals. Ensure correct polarity.

Bild 4.1: Simplified wiring diagram for the THC30A timer, illustrating connections for input power (IN) and output to the load (OUT).
4.2 Erstes Einschalten und Zurücksetzen
Upon initial power-up or after a prolonged power outage, the LCD display may be blank. The internal battery will charge, and the display should activate. If the display is erratic or unresponsive, press the ZURÜCKSETZEN button using a pointed object (e.g., a pen tip) to clear all settings and restore default values.

Bild 4.2: Detaillierte view of the THC30A timer's LCD screen, control buttons (P, D+, H+, M+, RESET, MANUAL), and working indicator.
4.3 Einstellen der aktuellen Uhrzeit
- Drücken Sie die UHR button (P) and hold it.
- Halten Sie UHRdrücken D+ to set the current day of the week (MON, TUE, WED, THU, FRI, SAT, SUN).
- Halten Sie UHRdrücken H+ um die aktuelle Stunde (0-23) einzustellen.
- Halten Sie UHRdrücken M+ um die aktuelle Minute (0-59) einzustellen.
- Lassen Sie den UHR Schaltfläche, um die Einstellungen zu speichern.
5. Bedienungsanleitung
5.1 Programmierung der Ein-/Ausschaltzeiten
The THC30A allows for up to 20 ON/OFF program settings. Each program consists of an ON time and an OFF time.

Bild 5.1: The THC30A timer's programming interface, highlighting its capacity for 20 ON/OFF settings, daily/weekly cycling, auto ON/OFF status, and a minimum setting time of 1 minute.
- Drücken Sie die P button (Program) once. The display will show '1 ON'.
- Drücken D+ to select the day(s) for this ON setting. You can choose a single day, a block of days (e.g., MON-FRI), or all 7 days.
- Drücken H+ to set the desired hour for the '1 ON' time.
- Drücken M+ to set the desired minute for the '1 ON' time.
- Drücken P Erneut wird im Display „1 AUS“ angezeigt.
- Repeat steps 2-4 to set the day(s), hour, and minute for the '1 OFF' time.
- Drücken Sie weiter P um die Modi '2 EIN', '2 AUS' bis '20 EIN', '20 AUS' durchzuschalten und jedes Programm nach Bedarf einzustellen.
- Nachdem Sie alle gewünschten Programme eingestellt haben, drücken Sie die Taste UHR button (P) to exit programming mode and return to the current time display.
5.2 Manuelle Übersteuerung
Der HANDBUCH Mit dieser Schaltfläche können Sie die programmierten Einstellungen vorübergehend überschreiben.
- Drücken HANDBUCH once: Switches from AUTO to ON (output is continuously ON).
- Drücken HANDBUCH again: Switches from ON to OFF (output is continuously OFF).
- Drücken HANDBUCH a third time: Switches from OFF to AUTO (timer resumes programmed operation).
6. Wartung
6.1 Batteriewechsel
The THC30A timer includes a built-in CR2032 lithium battery for power-off memory. This battery typically lasts for several years. If the display becomes dim or the time/settings are lost frequently during power outages, the battery may need replacement. Consult a qualified technician for battery replacement.
6.2 Reinigung
Wischen Sie die Außenseite des Timers mit einem weichen, trockenen Tuch ab. Verwenden Sie keine Scheuermittel oder Lösungsmittel, da diese den Timer beschädigen können.asing oder Anzeige.
7. Fehlerbehebung
- Anzeige ist leer: Check power supply. If power is present, the internal battery might be fully discharged; allow time for it to charge. If still blank, press the ZURÜCKSETZEN Taste.
- Timer schaltet nicht wie programmiert ein/aus:
- Stellen Sie sicher, dass der Timer eingeschaltet ist. AUTO mode (not ON or OFF via manual override).
- Überprüfen Sie, ob die aktuelle Uhrzeit und der aktuelle Tag korrekt eingestellt sind.
- Check that the programmed ON/OFF times and days are correct and active.
- Prüfen Sie, ob die Kabelverbindungen sicher und korrekt sind.
- Last erhält keinen Strom: Check the load device (e.g., bulb, motor) for functionality. Verify input power to the timer. Ensure the timer is in an ON state (either programmed ON or manually ON).
- Die Einstellungen gehen nach einem Stromausfall verloren.tage: The internal battery may be depleted. Consider replacing the CR2032 battery.
8. Spezifikationen

Bild 8.1: Dimensions of the TAXNELE THC30A Digital Programmable Timer Switch.
| Besonderheit | Spezifikation |
|---|---|
| Modell | THC30A |
| Typ | Digital LCD Power Timer |
| Material | Plastik |
| Aktuelle Bewertung | 30 A |
| Nennleistung | 5000 W |
| Bandtage Optionen | 12V DC/AC, 24V DC/AC, 48V DC/AC, 110V AC, 220V AC, 230V AC (model dependent) |
| Zeitfehler | ≤2 seconds/day |
| Anzeige | LCD |
| Programming Interval | 1 minute to 168 hours (weekly cycle) |
| EIN/AUS-Einstellungen | 20 EIN/AUS-Programme |
| Betriebstemperatur | -20℃ bis 50℃ |
| Abmessungen (L x B x H) | 86 x 36 x 65M (3.38 x 1.41 x 2.56 Zoll) |
| Gangreserve | 3V Lithium battery (CR2032) for data retention |
9. Garantieinformationen
TAXNELE products are manufactured to high-quality standards. This product is covered by a limited warranty against defects in materials and workmanship for a period specified by the retailer at the time of purchase. Please retain your proof of purchase for warranty claims. The warranty does not cover damage caused by improper installation, misuse, unauthorized modification, or natural disasters.
10. Unterstützung
For technical assistance, troubleshooting, or further inquiries regarding your TAXNELE THC30A Digital Programmable Timer Switch, please contact your retailer or the TAXNELE customer support channel provided with your purchase. When contacting support, please have your product model number (THC30A) and purchase information ready.