BSIDE A5X

BSIDE A5X Automatic Digital Multimeter

Model: A5X | Brand: BSIDE

1. Einleitung

The BSIDE A5X is a versatile and intelligent automatic digital multimeter designed for precise electrical measurements. Featuring a vibrant EBTN color LCD, it provides clear readings including test values, analog bars, and frequency/temperature. This device is equipped with smart auto-ranging capabilities, making it user-friendly for both beginners and experienced professionals. Its rechargeable lithium battery ensures long-lasting performance, and robust safety features provide protection against overload and burnout.

1.1. Lieferumfang

  • BSIDE A5X Rechargeable Multimeter
  • Messleitungen (rot und schwarz)
  • Protective EVA Case
  • Thermoelement (Temperaturfühler)
  • Typ C Ladekabel
  • Benutzerhandbuch (Englisch)
BSIDE A5X Multimeter and accessories

Figure 1.1: BSIDE A5X Multimeter with included test leads, charging cable, thermocouple, and protective case.

2. Sicherheitshinweise

Bitte lesen und verstehen Sie alle Sicherheitshinweise und Bedienungsanweisungen, bevor Sie dieses Multimeter verwenden. Andernfalls kann es zu Verletzungen oder Schäden am Messgerät oder am zu prüfenden Gerät kommen.

  • Always ensure the test leads are properly connected and the function selected is appropriate for the measurement.
  • Die für jeden Bereich angegebenen maximalen Eingangswerte dürfen nicht überschritten werden.
  • Bei Arbeiten an unter Spannung stehenden Stromkreisen ist äußerste Vorsicht geboten.
  • Do not use the meter if it appears damaged or if the test leads are frayed.
  • Replace the fuse only with the specified type and rating.
  • Halten Sie Hände und Finger während der Messungen hinter den Sondenbarrieren.
  • Vermeiden Sie die Verwendung des Messgeräts in feuchter Umgebung oder während Gewittern.

3. Einrichtung

3.1. Laden des Akkus

The BSIDE A5X is equipped with a built-in 700mAh rechargeable lithium-ion battery. Before first use, or when the low battery indicator appears, charge the device using the provided Type-C charging cable.

  1. Verbinden Sie das Typ-C-Ende des Ladekabels mit dem Ladeanschluss des Multimeters.
  2. Verbinden Sie das USB-A-Ende des Kabels mit einem Standard-USB-Netzteil (nicht im Lieferumfang enthalten) oder einem USB-Anschluss Ihres Computers.
  3. The charging indicator on the multimeter will show the charging status. Once fully charged, the indicator will change or turn off.
BSIDE A5X Multimeter charging via USB-C

Figure 3.1: The BSIDE A5X Multimeter features a built-in rechargeable 700mAh Li-ion battery, eliminating concerns about power depletion.

3.2. Erstes Einschalten

Halten Sie die Einschalttaste () to turn on the multimeter. The device will typically start in Smart Mode, automatically detecting the measurement type.

4. Bedienungsanleitung

The BSIDE A5X features an intelligent auto-identification system that simplifies measurements. In Smart Mode, it automatically detects and measures AC/DC voltage, AC/DC current, resistance, continuity, and frequency. For other functions, use the dedicated buttons.

4.1. Smart Mode Operation

When powered on, the multimeter defaults to Smart Mode. Simply connect the test leads to the circuit or component, and the meter will automatically identify and display the measurement (Voltage, Current, Resistance, Continuity, or Frequency).

4.2. Messung der Wechsel-/Gleichspannungtage

In Smart Mode, the meter automatically measures AC or DC voltage. Connect the red test lead to the 'VΩHz' input jack and the black test lead to the 'COM' input jack. Place the probes across the circuit points to measure voltage.

BSIDE A5X Multimeter measuring AC Voltage

Figure 4.1: The BSIDE A5X Multimeter automatically measures AC voltage, displaying both the voltage-Wert und Häufigkeit.

4.3. Messung von Wechsel-/Gleichstrom

For current measurements, the A5X features smart identification. Plug the test leads into the appropriate current input port (600mA for current measurements) and the 'COM' port. The tester will automatically switch to AC/DC ampere test mode.

BSIDE A5X Multimeter measuring current with smart identification

Figure 4.2: The BSIDE A5X Multimeter features Amp Smart Identification; simply plug into the amp port, and the tester automatically switches to AC/DC ampere test mode.

4.4. Widerstand messen

In Smart Mode, connect the test leads across the resistor. The meter will automatically detect and display the resistance value.

4.5. Kapazitätsmessung

To measure capacitance, press the 'FUNC' button until the capacitance symbol (μF) appears on the display. Important: Always discharge the capacitor before measuring to prevent damage to the meter or injury. Schließen Sie die Messleitungen an die Kondensatoranschlüsse an.

BSIDE A5X Multimeter measuring capacitance

Figure 4.3: Capacitance Test. Always discharge the capacitor before measuring to ensure safety and accurate readings.

4.6. Measuring Frequency and Duty Cycle

In Smart Mode, frequency is automatically displayed when measuring AC voltage. For dedicated frequency or duty cycle measurements, press the 'FUNC' button to cycle through modes until the Hz or % symbol appears. Connect the test leads to the signal source.

4.7. Temperatur messen

Connect the provided thermocouple to the multimeter's input jacks (ensure correct polarity). Press the 'FUNC' button until the temperature symbol (°C or °F) appears. Place the thermocouple probe at the point where temperature needs to be measured. The A5X can display both thermometer temperature and ambient environment temperature.

BSIDE A5X Multimeter dual-way temperature test

Figure 4.4: Dual-Way Temperature Test. The multimeter can measure both thermometer temperature (0°C~1000°C) and environment temperature (0°C~50°C).

4.8. Diodentest

Press the 'FUNC' button to select the diode test mode. Connect the red test lead to the anode and the black test lead to the cathode of the diode. The display will show the forward voltage drop. For a good silicon diode, this is typically around 0.5V to 0.8V. An open circuit (OL) indicates a faulty diode or incorrect polarity.

4.9. Durchgangsprüfung

In Smart Mode, continuity is automatically detected. Alternatively, press the 'FUNC' button to select continuity mode. Connect the test leads across the circuit or component. If the resistance is below approximately 30Ω, the meter will emit an audible beep, indicating continuity.

4.10. Berührungsloses Volumentage (NCV) Erkennung

Die NCV-Funktion ermöglicht die Erkennung von Wechselstromspannungen.tage without direct contact. Press the 'V-Alert' button to activate NCV mode. Move the top tip of the multimeter near the conductor. The meter will indicate the presence of AC voltage through visual and audible alerts. The A5X offers high and low sensitivity settings for NCV detection.

4.11. VFC (Variable Frequency Control) Test

The VFC function is designed to measure the output voltage of variable frequency drives (VFDs) or inverters. Press the 'FUNC' button to select VFC mode. Connect the test leads to the output of the VFD. This mode provides accurate readings for non-sinusoidal waveforms.

BSIDE A5X Multimeter performing VFD Test

Figure 4.5: The VFD function allows the BSIDE A5X Multimeter to accurately measure the output voltage of inverters.

4.12. Automotive Circuit Test

The BSIDE A5X can be used for various automotive electrical tests, such as checking battery voltage, alternator output, and continuity in wiring. Ensure the vehicle's electrical system is off before connecting test leads for continuity or resistance checks. For voltage checks, connect leads to the appropriate points (e.g., battery terminals).

BSIDE A5X Multimeter performing automotive circuit test

Figure 4.6: The BSIDE A5X Multimeter is suitable for various automotive circuit tests, including battery voltage prüft.

5. Wartung

5.1. Reinigung

Wischen Sie die Oberfläche des Zählers ab.asing mit Adamp cloth and mild detergent. Do not use abrasives or solvents. Ensure the meter is off and disconnected from any circuits before cleaning.

5.2. Batteriepflege

To prolong battery life, avoid fully discharging the battery frequently. Recharge the battery when the low battery indicator appears. If storing the meter for an extended period, charge it periodically to maintain battery health.

5.3. Sicherungswechsel

The BSIDE A5X is equipped with an easy-to-replace fuse for overload protection. If the current measurement function stops working, the fuse may need replacement. Refer to the specifications for the correct fuse type and rating. Disconnect all test leads and power off the meter before attempting fuse replacement.

6. Fehlerbehebung

  • Anzeige/Zähler schaltet sich nicht ein: Check battery charge level. Ensure the power button is pressed and held sufficiently.
  • Falsche Messwerte: Verify test lead connections. Ensure the correct measurement function is selected (if not in Smart Mode). Check for damaged test leads.
  • Keine aktuelle Messung: Check the fuse. Ensure test leads are connected to the correct current input jack.
  • Continuity Beeper Not Working: Ensure continuity mode is selected. Check if the resistance is above the threshold (approx. 30Ω).
  • NCV erkennt nicht: Ensure NCV mode is active. Check for proper proximity to the AC voltagDie Quelle.

7. Spezifikationen

ParameterSpezifikation
Anzeige6000 Counts, 2.2-inch EBTN Color LCD
DC-Voltage0V-620V (0.001V resolution) ±(0.5%+3)
AC-Lautstärketage0V-620V (0.001V resolution) ±(0.5%+5)
Gleichstrom1.0-610mA (0.1mA resolution) ±(1.5%+3)
Wechselstrom1.0-610mA (40-1000Hz) (0.1mA resolution) ±(1.5%+3)
Widerstand1Ω-999.9Ω (0.1Ω resolution) ±(2.0%+5); 1kΩ-60MΩ (0.1Ω resolution) ±(1.0%+3)
Kapazität1nF-999.9nF (0.001nF resolution) ±(6.0%+5); 1uF-99.99mF (0.001nF resolution) ±(3.0%+3)
Frequenz1Hz-1000Hz (ACV: 2V-10V) (0.001Hz resolution) ±(1.0%+5); 1KHz-60KHz (ACV: 10V-620V) (0.001Hz resolution) ±(1.0%+5)
Temperatur0-1000℃ (32-1832℉) (1℃/1℉ resolution) ±(2.0%+3)
Arbeitszyklus0.1%-99.9% (ACV: 2V-620V) (0.1% resolution) ±(3.0%+5)
DiodentestVorwärts-Voltage drop for diodes below 3.0V
NCV AlertAC-Lautstärketage 90V-1000V / 6V-1000V
KontinuitätBuzzer sounds if resistance is less than 30Ω
Stromversorgung3.7 V wiederaufladbare Lithiumbatterie
Maße140 x 53 x 32 mm
Gewicht125g

8. Garantie und Support

BSIDE products are manufactured to high-quality standards. For warranty information or technical support, please refer to the contact details provided with your purchase or visit the official BSIDE webBitte bewahren Sie Ihren Kaufbeleg für eventuelle Garantieansprüche auf.

© 2023 BSIDE. Alle Rechte vorbehalten.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.