Shutao STC-3028
STC-3028 24V Temperature & Humidity Controller User Manual
Model: STC-3028 (13443ST-1)
Brand: Shutao
Produkt überview
The STC-3028 is a versatile 24V temperature and humidity controller designed for precise environmental management. It features a dual digital display for simultaneous monitoring of temperature and humidity, making it ideal for applications such as incubators, terrariums, and other controlled environments. This device supports both heating/cooling and humidifying/dehumidifying functions.

Image: The STC-3028 controller unit with its integrated temperature and humidity sensor. The controller features a dual digital display showing temperature in red and humidity in blue.
Technische Spezifikationen
| Spezifikation | Wert |
|---|---|
| Eingangslautstärketage | Wechselstrom 24 V |
| Temperaturbereich messen | -50°C bis +110°C |
| Messbereich der Luftfeuchtigkeit | 00%RH to +100%RH |
| Temperaturgenauigkeit | ±1 °C |
| Feuchtigkeitsgenauigkeit | ± 0.1% RH |
| Relaisausgangskontaktkapazität | 10 A/240 V Wechselstrom |
| Anzeigetyp | Digitales |
| Material | Plastik |
| Abmessungen (L x B x H) | 75 mm x 85 mm x 27 mm (ca. 2.95 Zoll x 3.34 Zoll x 1.06 Zoll) |
| Artikelgewicht | 0.48 Unzen (ca. 0.03 Pfund) |

Image: Diagram showing the dimensions of the STC-3028 controller: 75mm (2.95 inches) length, 85mm (3.34 inches) width, and 27mm (1.06 inches) height.
Packungsinhalt
Das Paket enthält die folgenden Artikel:
- 1 x STC-3028 Temperature and Humidity Controller
- 1 x Integrated Sensor (for temperature and humidity measurement)
Setup und Installation
Schaltplan
Proper wiring is crucial for the safe and correct operation of the STC-3028 controller. Refer to the diagram below for connection details.

Image: A visual representation of the STC-3028 wiring diagram. It shows terminals for power supply (1-2), humidity sensor (3-5), and output relays for temperature (6-7) and humidity (8-9). The diagram also indicates voltage options (110-220VAC, 12V, 24V) and important notes regarding distinguishing interfaces and maintaining proper wire distance.
Wichtige Hinweise:
- Strictly distinguish the interface of the relay, sensor, and power supply.
- Strictly distinguish the connection of the sensor and power supply.
- Die Sensorzuleitung und das Stromkabel sollten in einem angemessenen Abstand zueinander verlegt werden, um Störungen zu vermeiden.
- Achten Sie auf die richtige Lautstärketage (24V) is supplied as indicated on the unit.
Montage
The STC-3028 is designed for panel mounting. Ensure adequate space for ventilation, especially around the heat dissipation grids on the sides of the unit.

Image: The STC-3028 controller with a visual representation of air flowing through its side vents, indicating effective heat dissipation. The image highlights the cooling grid design for efficient cooling.
Bedienungsanleitung
Setting Startup Temperature/Humidity
- Drücken Sie die "up" button once to display the current starting temperature or humidity setting.
- Drücken Sie lange die "up" button for approximately 3 seconds until the display flashes.
- Verwenden Sie die "up" Und "down" keys to adjust the desired starting temperature or humidity value.
- The setting will automatically save after a few seconds of inactivity or by pressing another button.
Setting Stop Temperature/Humidity
- Drücken Sie die "down" button once to display the current stop temperature or humidity setting.
- Drücken Sie lange die "down" button for approximately 3 seconds until the display flashes.
- Verwenden Sie die "up" Und "down" keys to adjust the desired stop temperature or humidity value.
- The setting will automatically save after a few seconds of inactivity or by pressing another button.
Temperature/Humidity Correction (Calibration)
To correct or calibrate the temperature and humidity readings:
- Drücken Sie die "up" Und "down" Tasten gleichzeitig.
- Follow the on-screen prompts to adjust the offset for temperature or humidity. Refer to the product's advanced settings for detailed calibration procedures if available.
Wartung
- Reinigung: Regularly wipe the unit with a soft, dry cloth. Do not use abrasive cleaners or solvents.
- Sensorpflege: Keep the integrated sensor clean and free from dust or debris to ensure accurate readings. Avoid exposing the sensor to extreme physical shock or moisture beyond its operating range.
- Belüftung: Ensure the ventilation grids on the sides of the unit are not obstructed to allow for proper heat dissipation.
- Stromabschaltung: Always disconnect power before performing any maintenance or wiring adjustments.
Fehlerbehebung
| Problem | Mögliche Ursache | Lösung |
|---|---|---|
| Display shows "LLL" or "HHH" | Sensor error, sensor disconnected, or reading out of range. | Check sensor connection. Ensure sensor is within operating temperature/humidity range. Replace sensor if damaged. |
| Gerät lässt sich nicht einschalten | Keine Stromversorgung, falsche Lautstärketage, oder fehlerhafte Verkabelung. | Verify power connection and ensure 24V AC supply. Check wiring according to the diagram. |
| Output relay not activating | Settings incorrect, or relay faulty. | Review startup and stop settings. Ensure the measured value is outside the set range to trigger the relay. Check relay wiring. |
| Ungenaue Messwerte | Sensor dirty, sensor interference, or needs calibration. | Clean the sensor. Ensure sensor wires are kept separate from power wires. Perform temperature/humidity correction. |