1. Produktüberschreitungview und Kit-Inhalt
The UEi EM720SPKIT is a comprehensive kit designed for precise measurement of static and differential pressure, crucial for HVAC/R technicians and professionals. It includes the EM720 manometer and various accessories to facilitate accurate readings in diverse applications.

Abbildung 1: The EM720SPKIT includes the EM720 manometer, various probes, tubing, fittings, and a soft carrying case for convenient transport and storage. The manometer displays pressure readings and temperature.
1.1. Lieferumfang
- EM720 Manometer (High resolution differential manometer with temperature compensation)
- Stepped T Fitting (2)
- Static Pressure Probe (2)
- Pressure Tubing with Brass Fitting (2)
- Step Connector with 3.15-inch Tubing (2)
- 60-inch Pressure Tube
- Batterien (vorinstalliert oder im Lieferumfang enthalten)
- Weiche Tragetasche
- Benutzerhandbuch (dieses Dokument)
2. Sicherheitshinweise
Bitte lesen und verstehen Sie alle Sicherheitshinweise und Bedienungsanleitungen, bevor Sie dieses Gerät verwenden. Andernfalls kann es zu Verletzungen oder Schäden am Gerät kommen.
- Always wear appropriate personal protective equipment (PPE) when working with pressure systems.
- Do not exceed the maximum pressure rating of ±80 in WC.
- Ensure all connections are secure before applying pressure.
- Setzen Sie das Instrument keinen extremen Temperaturen, hoher Luftfeuchtigkeit oder korrosiven Umgebungen aus.
- Remove batteries if the instrument is not used for an extended period to prevent leakage.
- Refer to local regulations and industry standards for specific application safety guidelines.
3. Einrichtung
3.1. Einlegen der Batterie
- Locate the battery compartment cover on the rear of the EM720 manometer.
- Öffnen Sie den Deckel durch Aufschieben oder Abschrauben.
- Insert the included batteries, observing the correct polarity (+ and -) as indicated inside the compartment.
- Bringen Sie den Batteriefachdeckel wieder fest an.
3.2. Connecting Probes and Tubing
The EM720SPKIT includes various accessories for different measurement scenarios:
- Static Pressure Measurement: Connect one static pressure probe to an input port (P1 or P2) on the top of the manometer using the pressure tubing.
- Differenzdruckmessung: Connect tubing from two different pressure points to both input ports (P1 and P2). Ensure P1 is connected to the higher pressure side and P2 to the lower pressure side for positive differential readings.
- Using Fittings: Utilize the stepped T fittings and step connectors as needed to adapt to different port sizes or to create a manifold for specific test setups.
Always ensure connections are snug to prevent pressure leaks, which can affect measurement accuracy.
4. Bedienungsanleitung
4.1. Ein-/Ausschalten
- To power on the EM720, press the LEISTUNG button (typically marked with a circle and vertical line symbol).
- Halten Sie zum Ausschalten die Taste gedrückt LEISTUNG button until the display turns off. The instrument may also have an auto-power off feature to conserve battery life.
4.2. Zeroing the Manometer
Before taking measurements, it is crucial to zero the manometer to ensure accuracy. Disconnect all pressure tubing from the input ports (or ensure both ports are open to ambient air) and allow the instrument to stabilize.
- Drücken Sie die DIF ZERO button. The display should show a reading close to zero.
- If the reading does not zero, ensure no pressure is applied to the ports and repeat the zeroing process.
4.3. Auswahl der Maßeinheiten
The EM720 supports multiple pressure units.
- Drücken Sie die EINHEITEN button to cycle through available pressure units (e.g., in WC, Pa, kPa, psi, mbar, mmHg).
- Select the unit appropriate for your application.
4.4. Data Hold, Min/Max/Avg Functions
- HALT: Drücken Sie die HALTEN Drücken Sie diese Taste, um den aktuellen Messwert auf dem Display einzufrieren. Zum Entsperren erneut drücken.
- MIN/MAX/AVG: Drücken Sie die REC MAX/MIN button to enter recording mode. Subsequent presses will cycle through Minimum, Maximum, and Average readings captured since entering the mode. Press and hold to exit recording mode.
4.5. Temperaturmessung
The EM720 also provides ambient temperature measurement, displayed alongside pressure readings. This feature aids in understanding environmental conditions that may affect pressure readings.
5. Wartung
5.1. Reinigung
- Wipe the instrument's exterior with a damp Tuch und Feinwaschmittel. Verwenden Sie keine Scheuermittel oder Lösungsmittel.
- Ensure no moisture enters the pressure ports or other openings.
5.2. Speicherung
- Store the EM720SPKIT in its soft carrying case when not in use to protect it from dust, dirt, and physical damage.
- An einem kühlen, trockenen Ort aufbewahren und vor direkter Sonneneinstrahlung und extremen Temperaturen schützen.
- Remove batteries if storing for extended periods to prevent battery leakage and potential damage to the instrument.
5.3. Kalibrierung
For continued accuracy, it is recommended to have the EM720 manometer calibrated periodically by a qualified service center. Refer to UEi Test Instruments' official website or contact customer support for calibration services and recommended intervals.
6. Fehlerbehebung
| Problem | Mögliche Ursache | Lösung |
|---|---|---|
| Das Gerät lässt sich nicht einschalten. | Defekte oder falsch eingesetzte Batterien. | Batteriepolarität prüfen; gegebenenfalls durch neue Batterien ersetzen. |
| Ungenaue oder schwankende Messwerte. | Unstable pressure source, leaky connections, or instrument not zeroed. | Ensure stable pressure; check all tubing and probe connections for leaks; perform zeroing procedure. |
| Display shows "OL" or "OVER". | Pressure input exceeds the instrument's range. | Disconnect from pressure source immediately. Do not exceed ±80 in WC. |
| Auto-power off too quickly. | Auto-power off feature enabled. | Refer to the full manual for instructions on disabling or adjusting auto-power off settings, if available. |
If the problem persists after attempting these solutions, please contact UEi Test Instruments customer support.
7. Spezifikationen
| Besonderheit | Detail |
|---|---|
| Technische Daten | 1 x 1 x 1 Zoll; 1 Pfund |
| Artikelmodellnummer | EM720SPKIT |
| Hersteller | UEI. |
| Druckmessbereich | ±80 in WC |
| Temperaturkompensation | Ja |
| Funktionen | HOLD, MIN/MAX/AVG, Ambient Temperature Measurement |
| Inhalt des Kits | EM720 manometer, stepped T fitting (2), static pressure probes (2), pressure tubing with brass fittings (2), step connector with 3.15-inch tubing (2), 60-inch pressure tube, batteries, soft case, manual |
8. Garantieinformationen
UEi Test Instruments products are designed for reliability and performance. For specific warranty terms and conditions applicable to the EM720SPKIT, please refer to the warranty card included with your product or visit the official UEi Test Instruments webBewahren Sie Ihren Kaufbeleg für Garantieansprüche auf.
9. Kundendienst
For technical assistance, troubleshooting, or service inquiries, please contact UEi Test Instruments customer support:
- WebWebsite: Besuchen Sie die offizielle UEi Test Instruments Store on Amazon oder deren Unternehmen website for FAQs, product documentation, and contact information.
- Telefon/E-Mail: Refer to the contact details provided in your product packaging or on the official webWebsite.
When contacting support, please have your product model number (EM720SPKIT) and purchase date available.