1. Produktüberschreitungview
The JMT HLK-LD2450 is a 24GHz radar module designed for real-time tracking of moving targets within a detection area. It provides distance, angle, and speed information of these targets via a serial port. This module is primarily intended for indoor applications such as smart homes, offices, and hotels, enabling precise positioning and tracking of people.

Abbildung 1: Überview of the JMT HLK-LD2450 radar module, illustrating its compact design for human movement trajectory tracking.
2. Hauptmerkmale
- Trajectory Tracking: Real-time tracking of moving targets, outputting distance, angle, and speed data.
- Application Scenes: Optimized for indoor environments including homes, offices, and hotels for human presence and movement detection.
- Erfassungswinkel: Azimuth ± 60° / Tilt ± 35°.
- Winkelgenauigkeit: 2° bis 20°.
- Erkennungsentfernung: Maximum sensing distance of 8 meters.
- Genauigkeit der Entfernungsmessung: 0.15 Meter.
- Datenausgabe: Serial ASCII format.
- Modulationsmodus: FMCW (Frequency Modulated Continuous Wave).
- Frequenz: 24G-24.25GHz (ISM band).
- Sweep Bandwidth: 250MHz (CE/FCC compliant).
- Baudrate der seriellen Schnittstelle: 256000, with 1 stop bit and no parity bit.
- Paket: Default 1.5mm x 4Pin Female connector.
3. Technische Daten
| Parameter | Wert |
|---|---|
| Frequenz | 24G-24.25GHz |
| Sweep-Bandbreite | 250MHz (CE/FCC compliant) |
| Modulationsmodus | FMCW |
| Netzteil Voltage | 5V (Typical) |
| Externe Dimension | 15mm x 40mm |
| Detection Angle (Azimuth) | ± 60° |
| Detection Angle (Tilt) | ± 35° |
| Maximale Erfassungsreichweite | 8m |
| Distance Defense Rate | 0.75 m |
| Genauigkeit der Entfernungsmessung | 0.15 m |
| Winkelgenauigkeit | 2° bis 20° |
| Datenaktualisierungsrate | 10 Hz |
| Umgebungstemperatur | -40°C ~ +85°C |
| Datenformat | Serial ASCII output |
| Baudrate der seriellen Schnittstelle | 256000 |
| Konfiguration der seriellen Schnittstelle | 1 stop bit, no parity bit |
| Steckertyp | 1.5mm x 4Pin Female (Default) |
| Artikelgewicht | 9.07 g (0.32 Unzen) |
4. Einrichtungsanweisungen
This section details the physical connection and initial configuration of the HLK-LD2450 module.
4.1. Modulschnittstelle
The module features a 4-pin interface for power and serial communication. Refer to the diagram below for pin assignments.

Abbildung 2: HLK-LD2450 module dimensions and interface pinout. The module measures 15mm x 40mm.
- 1: VCC - 5V Power Input
- 2: Masse - Strommasse
- 3: TX - Serial Transmission (Output from module)
- 4: RX - Serial Port Reception (Input to module)
Achten Sie auf die richtige Polarität und Lautstärketage when connecting the power supply. Incorrect connections may damage the module.
4.2. Physische Installation
The module is suitable for wall-mounted installation in indoor environments. Consider the detection angle specifications (Azimuth ± 60° / Tilt ± 35°) to optimize coverage for the desired tracking area.

Abbildung 3: The HLK-LD2450 module showing the pin headers for connection, designed for motion positioning and tracking.
5. Bedienungsanleitung
The HLK-LD2450 module communicates via a serial port, outputting target information in ASCII format.
5.1. Serial Communication Parameters
- Baudrate: 256000
- Stopp-Bits: 1
- Paritätsbit: Keiner
5.2. Using the Configuration Tool
To interact with the module and retrieve data, use the dedicated Configuration Tool (software provided separately by the manufacturer, if applicable). Follow these steps:
- Connect the HLK-LD2450 module to your computer via a serial interface (e.g., USB-to-serial converter).
- Open the Configuration Tool software.
- In the Configuration Tool, select the correct serial port number (COM port) corresponding to your connected module.
- Ensure the serial port information (baud rate, stop bits, parity) matches the module's specifications (256000, 1 stop bit, no parity).
- Click the "Detect Device" button within the Configuration Tool.
- Once the module is detected, click "Start" to begin receiving moving target information from the detection area.
Wichtiger Hinweis: The serial port tool and the host tool cannot be used simultaneously. Ensure only one application is accessing the serial port at any given time.
6. Wartung
The JMT HLK-LD2450 module is designed for reliable operation with minimal maintenance. Adhere to the following guidelines:
- Umgebungsbedingungen: Operate the module within the specified ambient temperature range of -40°C to +85°C. Avoid exposure to extreme humidity, dust, or corrosive environments.
- Reinigung: If necessary, gently clean the module's surface with a soft, dry cloth. Do not use liquid cleaners or solvents.
- Physische Handhabung: Handle the module with care to prevent physical damage to the PCB or components. Avoid bending or applying excessive force.
- Stromversorgung: Ensure a stable 5V power supply is used. Fluctuations or incorrect voltage kann die Leistung beeinträchtigen oder das Modul beschädigen.
7. Fehlerbehebung
This section provides solutions to common issues you might encounter with the HLK-LD2450 module.
7.1. No Data Output / Connection Issues
- Überprüfen Sie die Leistung: Verify that the module is receiving a stable 5V power supply and that the VCC and GND connections are correct.
- Serial Port Selection: Ensure the correct COM port is selected in your Configuration Tool or serial terminal software.
- Serial Port Parameters: Confirm that the baud rate is set to 256000, with 1 stop bit and no parity bit.
- Kabelverbindungen: Inspect all serial communication cables for proper connection and integrity. Ensure TX and RX lines are correctly cross-connected if using a direct serial connection (TX of module to RX of host, RX of module to TX of host).
- Softwarekonflikt: Remember that the serial port tool and the host tool cannot be used at the same time. Close any other applications that might be accessing the serial port.
- Treiberprobleme: Ensure that the drivers for your USB-to-serial converter (if used) are correctly installed and up-to-date.
7.2. Inaccurate or Intermittent Tracking
- Hindernisse: Ensure there are no significant physical obstructions (e.g., thick walls, large metal objects) between the module and the target area that could interfere with radar signals. While the module can detect through thin materials, dense objects will block signals.
- Einbaulage: Adjust the module's mounting position and angle to ensure optimal coverage of the desired detection area, considering the specified Azimuth and Tilt angles.
- Umwelteinflüsse: While 24GHz is robust, strong electromagnetic interference in the immediate vicinity could potentially affect performance.
8. Garantieinformationen
Specific warranty details for the JMT HLK-LD2450 module are not provided in the available product information. Please refer to the seller or manufacturer's official webDie Garantiebedingungen finden Sie auf der Webseite.
9. Kundendienst
For technical assistance, further documentation, or inquiries regarding the JMT HLK-LD2450 module, please contact your point of purchase or visit the official JMT website. Support contact information is not available in the provided product data.