IXITAB KWS-AC301/KWS-AC300

Bedienungsanleitung

KWS-AC301/KWS-AC300 Digital Power Energy Meter

1. Einleitung

This manual provides detailed instructions for the installation, operation, and maintenance of the IXITAB KWS-AC301/KWS-AC300 Digital AC Power Energy Meter. This device is designed to accurately measure and display AC voltage, current, active power, energy (kWh), and temperature. It is suitable for monitoring electrical parameters in various AC circuits.

2. Sicherheitshinweise

WARNUNG: Electrical shock hazard. Installation and servicing should only be performed by qualified personnel. Failure to follow these instructions may result in serious injury or death.

  • Ensure the power supply is disconnected before installation or wiring.
  • Überschreiten Sie nicht das angegebene Volumentage and current ratings (AC 50-300V, 100A).
  • Betreiben Sie das Gerät nicht bei Nässe oder damp Bedingungen.
  • Halten Sie das Gerät von brennbaren Materialien fern.
  • Vor dem Einschalten der Stromversorgung prüfen Sie, ob alle Verbindungen sicher und korrekt sind.

3. Produktüberschreitungview

The KWS-AC301/KWS-AC300 meter features a clear digital display for simultaneous monitoring of multiple electrical parameters. It is compact and designed for easy integration into electrical panels or systems.

Placeholder image indicating no product image available for the KWS-AC301/KWS-AC300 Digital Power Energy Meter.

Figure 3.1: Product image placeholder. This image indicates that a specific product image is not available. The actual product is a compact digital meter designed for AC electrical measurements.

Zu den Hauptmerkmalen gehören:

  • Real-time measurement of AC Voltage (V), Stromstärke (A), Wirkleistung (W) und Energie (kWh).
  • Temperaturanzeige.
  • Hohe Genauigkeit und Stabilität.
  • Leicht lesbare Digitalanzeige.

4. Aufbau und Verkabelung

Before proceeding, ensure the main power supply is OFF.

  1. Montage: Choose a suitable location for the meter, typically within an electrical panel or enclosure, ensuring adequate ventilation.
  2. Bandtage Input (L/N): Schließen Sie das AC-Voltage input wires to the designated L (Live) and N (Neutral) terminals on the meter. Ensure the voltage liegt im Wechselstrombereich von 50-300V.
  3. Stromwandleranschluss (CT):
    • Pass the load wire (the wire carrying the current you wish to measure) through the hole of the external current transformer (CT).
    • Connect the two small wires from the CT to the dedicated CT input terminals on the meter. Pay attention to polarity if indicated, though many simple CTs are non-polar for measurement.
  4. Lastanschluss: Ensure the load is correctly connected to the circuit being monitored.
  5. Einschalten: After all connections are verified and secure, restore power to the circuit. The meter should power on and display readings.

Note: The CT must be connected before applying power to the meter to avoid damage. Do not disconnect the CT while power is applied to the meter.

5. Bedienungsanleitung

Once powered on, the KWS-AC301/KWS-AC300 meter will automatically begin displaying the measured parameters. The display typically cycles through or shows simultaneously:

  • Bandtage(V): Zeigt die aktuelle Wechselstromspannung antage.
  • Strom (A): Displays the current AC amperage flowing through the monitored circuit.
  • Wirkleistung (W): Displays the instantaneous active power consumed by the load.
  • Energie (kWh): Accumulates the total energy consumed over time. This value is typically non-volatile and retained even after power loss.
  • Temperatur (°C/°F): Displays the ambient temperature measured by the device.

Some models may include a button for resetting the energy (kWh) reading. If present, press and hold the button for approximately 5 seconds to clear the accumulated energy data. Refer to specific product markings for button functionality.

6. Wartung

The KWS-AC301/KWS-AC300 meter requires minimal maintenance.

  • Reinigung: Verwenden Sie ein weiches, trockenes Tuch, um das Display und die Tastatur zu reinigen.asing. Verwenden Sie keine scheuernden Reinigungs- oder Lösungsmittel.
  • Inspektion: Überprüfen Sie regelmäßig die Drahtverbindungen, um sicherzustellen, dass sie fest sitzen.
  • Lagerung: If storing the device for an extended period, keep it in a dry, cool environment, away from direct sunlight and extreme temperatures.

7. Fehlerbehebung

ProblemMögliche UrsacheLösung
Anzeige/Zähler schaltet sich nicht einKeine Stromversorgung; falsche Verkabelung; defektes Gerät.Check power connections. Verify L/N wiring. Ensure power is applied. If problem persists, contact support.
Incorrect current reading (0A or very low)CT not connected; CT connected incorrectly; load wire not passed through CT.Ensure CT is properly connected to the meter. Verify the load wire passes through the CT. Do not disconnect CT while powered.
Falsche LautstärketagLesenFalsche Lautstärketage input wiring; voltage außerhalb des angegebenen Bereichs.Check L/N voltage input connections. Ensure voltage liegt im Bereich von 50-300V Wechselstrom.
Energy (kWh) not accumulatingNo current flow; faulty unit.Ensure there is an active load drawing current. Verify current reading is non-zero.

8. Spezifikationen

ParameterWert
ModellKWS-AC301 / KWS-AC300
Betriebslautstärketage ReichweiteWechselstrom 50-300 V
Aktueller Bereich0-100A
MessparameterBandtage, Current, Active Power, Energy (kWh), Temperature
Verpackungsabmessungen1.18 x 0.79 x 0.39 Zoll
Artikelgewicht1.76 Unzen
HerstellerIXITAB
ASINB0CSWFLZFL
Datum der ersten Verfügbarkeit20. Januar 2024

9. Garantie und Support

This product is manufactured by IXITAB. For warranty information, technical support, or service inquiries, please contact the seller or manufacturer directly through the platform where the product was purchased. Please have your purchase details and product model number (KWS-AC301/KWS-AC300) ready when contacting support.

For further assistance, you may refer to the product listing on Amazon.com.

© 2024 IXITAB. All rights reserved. Information subject to change without notice.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.