Ortis KJ-033

Ortis Hi-Lo Sump Pump Switch Controller KJ-033 User Manual

Modell: KJ-033

1. Einleitung

The Ortis Hi-Lo Sump Pump Switch Controller KJ-033 is an electronic adjustable float switch designed for automatic water level management in various applications such as sewage pits, fish tanks, and water tanks. It features stainless steel anti-corrosion dual sensors and supports both 220V and 110V AC power inputs. This manual provides detailed instructions for installation, operation, maintenance, and troubleshooting to ensure optimal performance and longevity of your device.

2. Sicherheitshinweise

Bitte lesen Sie vor der Installation und Inbetriebnahme alle Sicherheitshinweise sorgfältig durch. Die Nichtbeachtung dieser Hinweise kann zu Stromschlag, Brand oder schweren Verletzungen führen.

  • Elektrische Gefahr: Vor jeglichen Installations-, Wartungs- oder Fehlersucharbeiten muss die Stromversorgung unterbrochen sein.
  • Bandtage Kompatibilität: Überprüfen Sie, ob die Stromversorgungsspannungtage matches the controller's specifications (220V/110V AC).
  • Richtige Erdung: Always connect the device to a properly grounded outlet.
  • Wassereinwirkung: Do not immerse the controller unit in water. The controller unit is designed to be mounted above the water level.
  • Qualifiziertes Personal: Installation and electrical connections should be performed by qualified personnel if you are unsure.
  • Umgebungsbedingungen: Do not operate the device in explosive atmospheres or where flammable liquids or gases are present.

3. Produktmerkmale

The Ortis KJ-033 controller offers several features for reliable water level management:

  • Dual Stainless Steel Sensors: Anti-corrosion sensors for accurate water level detection.
  • Einstellbarer Sensorbereich: Sensors can be adjusted from 1/2 inch to 20 inches to define high and low water levels.
  • Mehrere Betriebsmodi: Supports Drain Mode (for emptying) and Water Mode (for filling).
  • LED-Anzeigen: Visual feedback for power, load status, and alarm conditions.
  • Überlastschutz: Integrated protection for connected pumps.
  • Mute-Funktion: Allows silencing of the alarm.
  • Breite Anwendung: Suitable for sewage pits, fish tanks, water tanks, and other water management systems.
Ortis Hi-Lo Sump Pump Controller with LED indicators, water mode, drain mode, compatibility, overload protection, and 3 load running modes.

Abbildung 3.1: Ortis Water Level Controller Overview with Key Features.

Application scenarios for the Ortis Water Level Controller including sewage pits, water towers, swimming pools, and fish tanks.

Abbildung 3.2: Various Application Scenarios for the Controller.

4. Einrichtung und Installation

Proper installation is crucial for the reliable operation of the controller.

4.1 Controller-Montage

The controller unit should be mounted in a dry location, above the maximum water level, and within reach of a grounded power outlet.

  • Schraubmontage: Use appropriate screws and anchors to secure the controller to a wall or stable surface through the mounting tabs.
  • Saugnapfmontage: For temporary or non-permanent installations, a suction cup can be used to attach the controller to a smooth, clean surface.
Diagram showing two installation methods for the Ortis Water Level Controller: screw mounting and suction cup mounting.

Abbildung 4.1: Controller Installation Methods.

4.2 Sensor Installation and Adjustment

The dual sensors detect the high and low water levels. Their position determines the operating range of your pump.

  • Sensorplatzierung: Position the sensors vertically in the water, ensuring they are securely fastened and will not move. The lower sensor defines the 'low' water level, and the upper sensor defines the 'high' water level.
  • Einstellbarer Bereich: The sensors can be adjusted along their cables to set the desired water level range, from 1/2 inch to 20 inches apart. Ensure both sensors are submerged at the desired 'on' level and the lower sensor is exposed at the desired 'off' level for drain mode, or vice versa for water mode.
  • Kabelmanagement: Route sensor cables to prevent entanglement or damage.
Diagram illustrating adjustable sensors with a range of 1/2 inch to 20 inches, showing how they are installed in water.

Abbildung 4.2: Adjustable Sensor Installation.

4.3 Elektrischer Anschluss

  • Netzstecker: Plug the controller's power cord into a grounded 220V or 110V AC outlet.
  • Pumpenanschluss: Plug your sump pump or other load device into the outlet on the front of the controller. Ensure the pump's power requirements do not exceed the controller's output capacity (15A, up to 2HP).
Example installation diagram showing the Ortis controller plugged into an outlet, with its sensors and connected pump in a sump pit.

Abbildung 4.3: Example Sump Pit Installation.

5. Bedienungsanleitung

The controller features a simple interface for selecting operating modes and managing alarms.

Close-up of the Ortis Water Level Controller's control panel, showing LED indicators for Drain, Water, DisAlarm, Mute, AUTO, OFF, ON, and Load.

Abbildung 5.1: Systemsteuerung überview.

5.1 Modusauswahl

Use the 'Drain' and 'Water' buttons to select the desired operating mode:

  • Ablassmodus: (LED indicator 'Drain' illuminates) In this mode, the controller activates the pump when the water level reaches the upper (high) sensor and deactivates it when the water level drops below the lower (low) sensor. This mode is typically used for emptying sewage pits or sumps.
  • Wassermodus: (LED indicator 'Water' illuminates) In this mode, the controller activates the pump when the water level drops below the lower (low) sensor and deactivates it when the water level reaches the upper (high) sensor. This mode is typically used for replenishing water in fish tanks or water tanks.

5.2 Power and Operation Switch

The main switch controls the power and operational state of the connected load:

  • WAGEN: (LED indicator 'AUTO' illuminates) The controller operates automatically based on the selected mode (Drain or Water) and sensor readings.
  • AUS: (LED indicator 'OFF' illuminates) The connected pump is turned off, regardless of water levels.
  • AUF: (LED indicator 'ON' illuminates) The connected pump is continuously turned on, regardless of water levels. Use this for manual override or continuous operation.

5.3 Mute-Funktion

Press the 'Mute' button to silence any active alarms. The 'DisAlarm' LED will illuminate when the alarm is muted.

Diagram illustrating how the Hi-Lo pump switch works in sewage pits, showing the pump turning off when water is below the Lo sensor and turning on when water reaches the Hi sensor.

Abbildung 5.2: Operational Logic in Drain Mode (Sewage Pit Example).

6. Wartung

Regular maintenance ensures the longevity and reliable operation of your Ortis controller.

  • Sensorreinigung: Periodically inspect and clean the stainless steel sensors to remove any buildup of debris, algae, or mineral deposits that could affect their accuracy. Disconnect power before cleaning.
  • Kabelinspektion: Check all cables and connections for signs of wear, damage, or corrosion. Replace any damaged components immediately.
  • Steuereinheit: Keep the controller unit clean and dry. Avoid exposing it to direct sunlight or extreme temperatures.
  • Testbetrieb: Periodically test the controller's operation by manually raising or lowering water levels to ensure the pump activates and deactivates as expected in the selected mode.

7. Fehlerbehebung

In der folgenden Tabelle finden Sie häufig auftretende Probleme und deren Lösungen.

ProblemMögliche UrsacheLösung
Pump does not turn on/off automatically.1. Controller not in AUTO mode.
2. Sensors are dirty or improperly positioned.
3. Pump is not plugged in or is faulty.
1. Ensure the switch is set to 'AUTO'.
2. Clean sensors and verify their high/low positions.
3. Check pump connection and functionality.
Der Alarm ertönt häufig.1. Water level not reaching desired sensor within expected time.
2. Fehlfunktion des Sensors.
3. Alarm sensitivity setting (if applicable, check product documentation).
1. Check pump operation and water flow. Adjust sensor positions if needed.
2. Inspect sensors for damage or debris. Replace if faulty.
3. Use the 'Mute' button temporarily. Consult manufacturer for alarm logic details.
Controller hat keinen Strom.1. Netzkabel abgezogen.
2. Die Steckdose hat keinen Strom.
3. Interne Sicherung durchgebrannt.
1. Ensure power cord is securely plugged in.
2. Test the outlet with another device. Check circuit breaker.
3. Wenden Sie sich an den Kundendienst, um Hilfe zu erhalten.
Pump runs continuously in AUTO mode.1. Sensor stuck in 'on' position (e.g., upper sensor always wet in Drain Mode).
2. Fehlfunktion des Controllers.
1. Clean and reposition sensors. Ensure they can freely detect water level changes.
2. Disconnect power and reconnect. If issue persists, contact support.

8. Spezifikationen

Diagram showing the dimensions of the Ortis Water Level Controller: 3.9 inches length, 3.3 inches height, 1.6 inches depth. Sensor cables are 16 feet long, and the power cord is 1.3 feet long.

Abbildung 8.1: Abmessungen des Controllers.

BesonderheitSpezifikation
ModellKJ-033
MarkeOrtis
Eingangslautstärketage220 V / 110 V Wechselstrom
Ausgangsstrom15 A
Maximale LastleistungBis zu 2 PS
SensormaterialEdelstahl
Adjustable Sensor Range1/2 Zoll bis 20 Zoll
HerstellerFJKJ INC.

9. Garantie und Support

For warranty information and technical support, please refer to the product packaging or contact the seller/manufacturer directly. Keep your purchase receipt as proof of purchase.

Hersteller: FJKJ INC.