GBHJJ IR6500

GBHJJ IR6500 BGA Infrared Rework Station User Manual

1. Einleitung

This manual provides comprehensive instructions for the safe and efficient operation, setup, and maintenance of the GBHJJ IR6500 BGA Infrared Rework Station. This equipment is designed for precise soldering, desoldering, and repair of various packaged devices, including BGA, PBGA, CSP, multi-layer substrates, EMI metal shielding products, and lead-free re-soldering applications.

Hauptmerkmale:

  • Erweiterte Temperaturregelung: Features 8 heating sections and 8 constant temperature sections, allowing for precise control. Up to 10 sets of temperature curves can be saved.
  • Innovative Airflow Management: Designed to minimize the impact of airflow on temperature accuracy, facilitating lead-free soldering rework.
  • Secure PCB Fixture: Equipped with a linear rail-type bracket and special-shaped rod for easy and secure locking and adjustment, preventing PCB deformation.
  • Integriertes Design: Compact and integrated system design reduces workbench area requirements and cable clutter.
  • Wide Application Scope: Suitable for BGA rework on various motherboards, including laptops, desktops, servers, industrial computers, game consoles, communication equipment, and LCD TVs.

2. Sicherheitshinweise

WARNUNG: Die Nichtbeachtung dieser Sicherheitshinweise kann zu Stromschlag, Brand oder schweren Verletzungen führen.

  • Always connect the rework station to a grounded power outlet with the correct voltage (220 V).
  • Do not operate the equipment in damp oder nassen Bedingungen.
  • Ensure adequate ventilation in the work area to dissipate fumes and heat.
  • The heating elements reach high temperatures. Avoid direct contact with hot surfaces. Use appropriate heat-resistant gloves.
  • Vor jeglichen Wartungs- oder Reinigungsarbeiten die Stromzufuhr unterbrechen.
  • Keep children and unauthorized personnel away from the operating equipment.
  • Das Gerät darf nicht verändert werden. Verwenden Sie ausschließlich vom Hersteller zugelassene Ersatzteile.
  • Tragen Sie stets geeignete persönliche Schutzausrüstung (PSA), einschließlich einer Schutzbrille.

3. Packungsinhalt

Verify that all items listed below are present in your package. If any items are missing or damaged, contact your supplier immediately.

GBHJJ IR6500 BGA Infrared Rework Station and accessories

Bild 3.1: Überview of the GBHJJ IR6500 BGA Infrared Rework Station and included accessories. This image displays the main rework station unit, power cable, USB cable, aluminum foil tape, and a thermocouple.

  • GBHJJ IR6500 BGA Infrared Rework Station Unit
  • Power Cable (AC220V compatible)
  • USB-Kabel
  • Aluminiumfolienband
  • Thermoelement
  • Benutzerhandbuch (dieses Dokument)

4. Einrichtungsanweisungen

  1. Auspacken und Aufstellen:

    Carefully remove all components from the packaging. Place the rework station on a stable, level, and heat-resistant workbench. Ensure there is sufficient space around the unit for ventilation and operation.

  2. Stromanschluss:

    Connect the provided power cable to the AC220V power inlet on the rear of the rework station. Ensure the power switch (circuit breaker) is in the OFF position before plugging the other end into a grounded 220V power outlet.

    Hinteren view of GBHJJ IR6500 showing AC220V power inlet

    Bild 4.1: Rear panel of the IR6500, highlighting the AC220V power input connector and the CE marking.

    Hinteren view of GBHJJ IR6500 with fan and power input

    Bild 4.2: Ein anderer view of the rear panel, showing the cooling fan on the left and the power input with an integrated circuit breaker on the right.

    Close-up of the circuit breaker on GBHJJ IR6500

    Bild 4.3: Detaillierte view of the integrated circuit breaker, labeled "ADVANCON LZ47-63", which serves as the main power switch for the unit.

  3. PCB Board Mounting:

    Utilize the linear rail-type bracket system to securely hold the PCB board. Adjust the special-shaped rod and rotate the handles to lock the PCB in place, ensuring it is stable and flat to prevent deformation during the rework process.

    Spitze view of GBHJJ IR6500 with PCB mounting rails

    Bild 4.4: Von oben nach unten view of the IR6500, illustrating the adjustable PCB mounting rails and the upper heating element assembly.

  4. Thermocouple Placement:

    Connect the thermocouple to the designated input on the control panel. Position the thermocouple tip as close as possible to the component being reworked, ideally under the component or on an adjacent test point, to accurately monitor the temperature.

5. Bedienungsanleitung

The IR6500 features a user-friendly control panel for precise temperature management.

Control panel of GBHJJ IR6500 BGA Rework Station

Bild 5.1: Close-up of the control panel, showing the "Lower TEMP Controller" and "Upside TEMP Controller" displays, along with various buttons for programming, manual control, and start/stop functions. Also visible are the Lighting Switch and Fan Switch.

  1. Einschalten:

    After completing the setup, switch the main circuit breaker (Image 4.3) to the ON position. The digital displays on the control panel will illuminate.

  2. Temperatur Profile Einstellung:

    The rework station allows for setting 8 heating sections and 8 constant temperature sections. Use the "PROG" button and navigation keys on the "Upside TEMP Controller" to access and modify temperature profiles. You can save up to 10 distinct temperature curves for different applications.

    • PV (Prozesswert): Zeigt die aktuelle Temperatur an.
    • SV (Set Value): Zeigt die Zieltemperatur an.
    • Refer to the detailed programming guide in the full manual for specific steps on creating and saving temperature profiles.
  3. Manuelle Kontrolle:

    For quick adjustments or specific tasks, the "MAN" (Manual) mode can be engaged. This allows direct control over heater power output. Exercise caution when using manual mode to avoid overheating components.

  4. Starting the Rework Process:

    Once the desired temperature profile is selected or manual settings are configured, press the Start-Taste to initiate the heating cycle. Monitor the temperature displays and the component being reworked.

  5. Stopping the Rework Process:

    To stop the heating cycle at any time, press the Stopptaste. The heaters will turn off, and the cooling fan may activate to dissipate residual heat.

  6. Lighting and Fan Switches:

    Verwenden Sie die Lichtschalter to turn on the integrated work light for better visibility. The Lüfterschalter controls the auxiliary cooling fan, which can be used to accelerate cooling after a rework cycle or for general ventilation.

6. Wartung

Regular maintenance ensures the longevity and optimal performance of your IR6500 BGA Infrared Rework Station.

  • Reinigung:

    After each use, allow the unit to cool completely. Use a soft, dry cloth to wipe down the exterior surfaces. For stubborn residues, a mild, non-abrasive cleaner can be used sparingly. Do not use solvents or harsh chemicals. Keep the heating elements and sensors free from dust and debris.

  • Ventilator und Belüftung:

    Periodically inspect the cooling fan vents on the rear of the unit (Image 4.2) and clean any accumulated dust to ensure proper airflow.

  • Lagerung:

    When not in use, store the rework station in a clean, dry environment, away from direct sunlight and extreme temperatures.

  • Kabelinspektion:

    Regularly check the power cable and other connections for any signs of wear, cuts, or damage. Replace damaged cables immediately.

7. Fehlerbehebung

This section addresses common issues you might encounter with your IR6500 BGA Infrared Rework Station.

ProblemMögliche UrsacheLösung
Gerät lässt sich nicht einschalten.
  • Netzkabel nicht angeschlossen.
  • Der Leistungsschalter ist AUS oder ausgelöst.
  • Kein Strom aus der Steckdose.
  • Stellen Sie sicher, dass das Stromkabel fest angeschlossen ist.
  • Switch circuit breaker to ON. If tripped, reset it.
  • Test outlet with another device or check building's circuit breaker.
Heaters not reaching set temperature.
  • Incorrect temperature profile ausgewählt.
  • Thermocouple improperly placed or faulty.
  • Heater element malfunction.
  • Verify the selected temperature profile.
  • Ensure thermocouple is in good contact with the PCB/component. Check for damage.
  • Contact technical support if heater elements are suspected to be faulty.
PCB board is deforming.
  • PCB not securely mounted.
  • Excessive or uneven heating.
  • Re-secure the PCB using the linear rail-type bracket.
  • Adjust temperature profile to a slower ramp rate or lower peak temperature.

If you encounter issues not covered in this section, or if troubleshooting steps do not resolve the problem, please contact customer support.

8. Spezifikationen

ParameterWert
ModellIR6500
HeizungsartInfrarot (IR)
Abmessungen (L x B x H)475 x 480 x 420 mm (18.7 x 18.9 x 16.54 Zoll)
Gewicht15 kg (41.8 Pfund)
Stromversorgung220 V
Universal Power Consumption1250 W
Leistung der oberen Heizung400 W
Top Heater Dimensions80 mm x 80 mm
Bottom Heater Power800 W
Bottom Heater Dimensions120 mm x 120 mm
Genauigkeit der Temperaturregelung±0.5 %
Applicable Chip Size≤70mm × 70mm
Applicable PCB Size≤400mm × 305mm
AnzeigetypLED-Digitalanzeige
MaterialMetall

9. Garantie und Support

GBHJJ provides a standard manufacturer's warranty for this product. For specific warranty terms and conditions, please refer to the documentation included with your purchase or contact your retailer.

For technical support, troubleshooting assistance, or inquiries regarding parts and service, please contact GBHJJ customer service through your purchase platform or the official GBHJJ webWebsite.

© 2024 GBHJJ. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.