1. Einleitung und Produktübersichtview
The DIHOOL Electric Lift Table, Model US-DHLCE-S395A, is a three-section electric lifting column designed for adjustable height applications. It is driven by a DC motor and constructed with aluminum oxide material for durability and efficient heat dissipation. This lifting platform is suitable for various uses, including medical appliances, home elevator systems, children's photography chairs, Japanese tatami tables, hidden lifting tables, children's toy tables, and laser printers.
Key features include a maximum load capacity of 80KG (180LB) and an adjustable height range. The system incorporates a current limit protection system that automatically disconnects the circuit if the load exceeds 80KG or an obstacle is detected, protecting the motor from damage. The controller supports multiple control methods, including remote, button, wire, and WiFi.

Bild 1.1: Überview of the DIHOOL Electric Lift Table's 3-section sleeve lifting structure, built-in limit switch, and quiet operation. The structure allows for simultaneous lifting and lowering of double-layer aluminum tubes, enhancing aesthetics. A built-in limit switch prevents damage from the internal telescopic push rod extending too far. The unit operates at a quiet 30dB.

Image 1.2: Illustration of the lift table's high load capacity. It has a no-load speed of 10mm/s (0.4inch/s) and a maximum load capacity of 200kg (450lbs). For optimal performance and longevity, it is recommended to operate at 80% of the maximum load capacity (160kg/352lbs) and avoid continuous long-term operation, with a maximum continuous runtime of 20 minutes.
2. Sicherheitshinweise
Read all instructions carefully before installation and operation. Failure to follow these instructions may result in injury or damage to the product.
- Tragfähigkeit: Do not exceed the maximum load capacity of 80KG (180LB). The static load capacity is 120KG (260LB). Overloading can cause damage to the motor and lifting mechanism.
- Hinderniserkennung: The controller features a current limit protection system. If the load exceeds the maximum or an obstacle is encountered, the system will automatically disconnect to prevent motor damage. However, always ensure the path of movement is clear.
- Dauerbetrieb: The motor requires heat dissipation. Avoid continuous operation for extended periods. The operating frequency is a 10% working system, with a maximum continuous run time of 20 minutes. After 20 minutes of continuous operation, allow the unit to cool down.
- Stromversorgung: Stellen Sie sicher, dass die Stromversorgungslautstärketage matches the product specifications (AC100V-220V for power supply, DC24-30V for DC Motor).
- Installation: Follow installation guidelines carefully. For ceiling installations, ensure the load capacity is less than 140KG and use specialized expansion screws. Lateral installation is prohibited and will void the warranty for any resulting damage.
- Kinder und Haustiere: Keep children and pets away from the lift table during operation to prevent accidents.
- Umgebungsbedingungen: Operate the lift table within the specified temperature range of -15°C to +65°C.
3. Produktspezifikationen
The following table details the technical specifications for the DIHOOL Electric Lift Table, Model US-DHLCE-S395A.

Image 3.1: Detailed parameters and dimensions for various DIHOOL electric lift table models, including DHLCE-S395A. This model features an initial height of 370mm (14.6in), a final height of 765mm (30.1in), and a stroke length of 395mm (15.6in). It is a 3-section unit with a voltage range of DC20-32V, a no-load speed of 10mm/s, and a max load capacity of 200KG (450LB). It includes built-in limit switches and operates at a 10% work system, with a maximum of 20 minutes continuous working time. The material is body aluminum with an iron panel.
| Spezifikation | Wert |
|---|---|
| Modell | US-DHLCE-S395A |
| Maximale Tragfähigkeit | 80 kg |
| Statische Belastbarkeit | 120 kg |
| Min. Höhe | 360MM (14.17") |
| Max. Höhe | 790MM (31.10") |
| Strichlänge | 430 MM |
| Geschwindigkeit | 10 MM/S |
| Column Width | 144 x 144 mm |
| Dimensions (L.W.H) | 200*200*360 MM |
| Bandtage (Stromversorgung) | AC100V-220V |
| Bandtage (DC Motor) | Gleichstrom 24-30 V |
| Amperage Kapazität | 3 Amps |
| Oberflächenbehandlung | Electrophoretic black |
| IP-Schutzart | IP43 |
| Betriebstemperatur | -15°C ~ +65°C |
| Betriebsfrequenz | 10% working system, maximum 1 hour work continue (Note: Image 3.1 states max 20 min continuous working) |
| Material | Aluminiumoxid |
| Geräuschpegel | 40 Dezibel |
| Im Lieferumfang enthaltene Komponenten | Regler |
| Montage erforderlich | Ja |
| Artikelgewicht | 9 Kilogramm |
4. Einrichtung und Installation
This section provides guidance on installing your DIHOOL Electric Lift Table. Ensure all components are present before beginning installation.
4.1 Mitgeliefertes Zubehör
Im Paket ist die für die Installation notwendige Hardware enthalten:
- M8*20 Bolts (8pcs)
- M8 Nuts (8pcs)
- M5*25 Screws (16pcs)

Image 4.1: Description of included accessories (M8*20 Bolts, M8 Nuts, M5*25 Screws) and examples of installation methods. For wooden board installation, use M5*25 screws. For steel plate installation, use M8*20 bolts and M8 nuts. The image also highlights customizable options for enclosure color, upper/lower panels, and power interface.
4.2 Installationsumgebungen
The lift table can be installed in various configurations. Always ensure the desktop size does not exceed 80*80cm. If the length and width of the desktop exceed 80cm, it is recommended to use 2 or more columns.

Image 4.2: Illustrations of different installation methods. Forward Installation: The desktop size should not exceed 80*80cm. Avoid placing excessive weight on the edge of the desktop; ensure the load's center of gravity is positioned at the center. Umgekehrte Installation: Similar desktop size and weight distribution guidelines apply. Deckenmontage: Use specialized expansion screws. If the lift is suspended from the ceiling, modify parameters for up and down current. Load capacity must be less than 140KG. Seitlicher Einbau: Side mounting is prohibited. Any resulting damage will not be covered under warranty.
- Forward Installation: Mount the lift table with the motor facing downwards. Ensure the load is centered to prevent tipping.
- Umgekehrte Installation: Mount the lift table with the motor facing upwards. Ensure the load is centered.
- Deckenmontage: This method requires specialized expansion screws. If suspending the lift from the ceiling, it is crucial to adjust the parameters for the up and down current in the controller. The load capacity for ceiling installation must be less than 140KG.
- Seitlicher Einbau: Side mounting is strictly prohibited. Any damage resulting from lateral installation will not be covered under warranty.
4.3 Stromversorgungsmethoden
The lift table can be powered by various methods, including 12V, 20V-30V, 110V, or 220V.

Image 4.3: Demonstrates multiple power supply methods. The actuator can operate directly on 12V power, achieving 5mm/s speed with a maximum load capacity of 100kg. A boost converter (12V to 24V) can be used to enable full-power operation. Examples include AC adapter (AC120V/AC240V), automotive power receptacle (DC12V input with boost converter), storage battery (DC24V), and power bank (100W PD3.0/PD3.1). Common applications shown are elevating photography platforms, laser marking machines, tatami beds, and elevating tables for RVs.
5. Bedienungsanleitung
The DIHOOL Electric Lift Table features a pre-wired controller with seven available control modes for convenient operation.
5.1 Controller Description

Image 5.1: Detailed diagram of the DIHOOL DC Motor Controller (Model: IPS-S2). It shows various components including the motor connection (6-30V DC Power), WiFi indicator light, WiFi pairing button, current display, and control buttons (F1, F2, F3, Up, Down, Set). The image also outlines the functions of F1 (Motor Protection Setting), F2 (Signal Operation Setting), and F3 (Automatic Operation Setting) with their respective sub-functions and parameter descriptions.
5.2-Kontrollmethoden
The lifting column is pre-wired, simplifying setup. Seven control modes are available:
- Fernbedienung
- Handle-Controller
- IPS-S2 Controller (Main unit)
- WiFi-Steuerung
- Function F3 programmable automatic lifting
- IN2 IN3 I/O Signal Control Button (Purchase separately)
- Function F2 Photoelectric switch control (Purchase separately)
5.3 Controllerfunktionen
The controller features three main function buttons (F1, F2, F3) for advanced settings:
- F1: Motor Protection Settings
Press F1 to enter sub-function settings. Use the up/down arrows to select and adjust parameters such as Current Limit Up/Down, Running Time Up/Down, Rebound Time, Reduce Voltage for Up/Down, and Standby Time. - F2: Signal Operation Settings
Press F2 to enter sub-function settings. Adjust parameters like Up/Down Working Time, Motor Running Time, Operation Mode (Signal present, stop; Signal disappear, execute actions A,b,c; Signal present, execute actions A,b,c; Signal disappear, execute actions b and c), and Motor Not Working. - F3: Automatic Operation Settings
Press F3 to enter sub-function settings. Adjust parameters such as Up/Down Working Time, Pause Time, Down Working Time, Number of Cycles, and Cycle Delay Mode.
Zeitsteuerung: If a specific height is desired (e.g., 200MM), calculate the time required to reach that height and then set parameter C (time) within the F3 Automatic Operation Settings.
Downward Current Setting: The controller allows setting a downward current 0.2~0.3A higher than the indicated current. This feature helps prevent objects from being caught during downward movement.
6. Wartung
Regular maintenance ensures the longevity and optimal performance of your DIHOOL Electric Lift Table.
- Reinigung: Periodically clean the exterior of the lift column with a soft, dry cloth. Avoid using abrasive cleaners or solvents that could damage the aluminum oxide finish.
- Inspektion: Regularly inspect all cables and connections for any signs of wear, fraying, or damage. Ensure all mounting bolts and screws are securely tightened.
- Schmierung: The internal mechanism is generally maintenance-free. Do not attempt to lubricate internal components unless specifically instructed by DIHOOL support.
- Überlastungsschutz: Always adhere to the maximum load capacity of 80KG (180LB). Operating the unit beyond its rated capacity can lead to premature wear and motor failure.
- Abkühlungsphasen: Respect the operating frequency of 10% working system, with a maximum continuous run time of 20 minutes. Allow the motor to cool down after extended use to prevent overheating.
- Umweltschutz: Keep the lift table in an environment within the specified operating temperature range and protect it from excessive moisture or dust, which can affect electrical components.
7. Fehlerbehebung
This section addresses common issues you might encounter with your electric lift table. If the problem persists, contact customer support.
| Problem | Mögliche Ursache | Lösung |
|---|---|---|
| Lift table does not move | Keine Stromversorgung Lose Kabelverbindung Überlastschutz aktiviert Fehlfunktion des Controllers | Check power outlet and cable connections. Stellen Sie sicher, dass alle Kabel fest eingesteckt sind. Reduce load; check for obstacles. Allow motor to cool if recently overloaded. Refer to controller manual or contact support. |
| Lift table moves slowly or intermittently | Unzureichende Leistung Partial overload Überhitzung des Motors | Ensure stable power supply. Check voltage. Reduce load to below maximum capacity. Allow the unit to cool down. Avoid continuous operation. |
| Ungewöhnliche Geräusche während des Betriebs | Obstruction in lifting mechanism Lose Komponenten Motorproblem | Inspect the lifting column for any foreign objects. Überprüfen Sie alle Befestigungsteile auf festen Sitz. Sollten die Geräusche weiterhin auftreten, stellen Sie die Nutzung ein und kontaktieren Sie den Support. |
| Die Controller-Anzeige funktioniert nicht. | Keine Stromversorgung zum Controller Controller cable issue | Check main power and controller connection. Ensure controller cable is not damaged or loose. |
| WiFi control not connecting | Incorrect WiFi settings Routerprobleme | Refer to the controller manual for WiFi setup instructions. Ensure correct network and password. Starten Sie Ihren WLAN-Router neu. |
8. Garantie und Support
For specific warranty terms and conditions, please refer to the documentation provided with your purchase or contact DIHOOL customer service directly. Warranty coverage typically includes defects in materials and workmanship under normal use.
Kundendienst:
If you encounter any issues not covered in this manual or require further assistance, please contact DIHOOL customer support. Have your product model number (US-DHLCE-S395A) and purchase information ready when contacting support.
Contact information can typically be found on the DIHOOL official webauf der Website oder auf Ihrer Produktverpackung.