Loom Solar Fusion

Loom Solar Fusion 3kW On-Grid Solar Inverter User Manual

Marke: Loom Solar | Modell: Fusion 3kW, 1Phase

1. Einleitung

This user manual provides essential information for the safe and efficient operation, installation, and maintenance of your Loom Solar Fusion 3kW, 1Phase On-Grid Solar Inverter. Please read this manual thoroughly before installation and operation, and keep it for future reference.

Loom Solar Fusion 3kW On-Grid Solar Inverter

Figure 1: Loom Solar Fusion 3kW On-Grid Solar Inverter, front view.

2. Sicherheitshinweise

Safety is paramount when dealing with electrical equipment. Adhere to all local and national electrical codes. Only qualified personnel should perform installation and maintenance.

  • Intelligent AFCI (Arc-fault Circuit Interrupter) Protection: The inverter is equipped with AFCI protection that cuts off DC arcs within 0.5 seconds to prevent potential fire hazards.
  • AC/DC-Überspannungsschutz: Integrated lightning protection safeguards the inverter and connected systems from electrical surges.
  • IP65-Schutz: The inverter's robust design ensures it is dustproof, waterproof, and anti-salt fog, providing durability in various environmental conditions.
  • Always disconnect all power sources (DC and AC) before performing any service or maintenance.
  • Versuchen Sie nicht, den Wechselrichter selbst zu öffnen oder zu reparieren. Wenden Sie sich an qualifiziertes Servicepersonal.
Safety Shield Icon

Überlegene Sicherheit

Blitzsymbol

Überspannungsschutz

3. Produktmerkmale

The Loom Solar Fusion 3kW On-Grid Solar Inverter is designed with advanced technology to provide reliable and efficient solar power conversion for residential applications.

  • Hohe Effizienz: Achieves an industry-leading conversion efficiency of 98% through advanced power electronics technologies.
  • Fernüberwachung: Supports remote monitoring via GPRS/Wifi Kit, WLAN, and Ethernet, allowing you to track performance from anywhere.
  • Breiter MPPT-Volumentage Reichweite: Features an extra-wide Maximum Power Point Tracking (MPPT) voltage range for optimized energy harvesting.
  • Robustes Design: Built to withstand extreme weather conditions including high temperatures, snow, sandstorms, and rain.
  • Intelligentes Design: Easy to install with an intuitive LED display for local monitoring.
On-Grid Solar Inverter features: Max 98.1% Efficiency, AC/DC Lightening Protection, Reliable Heat Dissipation, Various Complex Grid Adaptable

Figure 2: Key features of the Loom Solar On-Grid Solar Inverter.

4. Einrichtung und Installation

Installation of the Loom Solar Fusion inverter should only be performed by certified and qualified solar professionals. Improper installation can lead to equipment damage, personal injury, or voiding of warranty.

  • Standortauswahl: Choose a well-ventilated area, protected from direct sunlight and excessive moisture. Ensure adequate clearance around the inverter for heat dissipation.
  • Montage: Securely mount the inverter to a sturdy wall or frame using appropriate hardware.
  • Elektrische Anschlüsse: Connect the DC input from the solar panels and the AC output to the grid according to the wiring diagram provided in the full installation guide (not included in this manual). Ensure all connections are tight and correctly polarized.
  • Erdung: Properly ground the inverter as per local electrical codes.

5. Bedienungsanleitung

Once installed and connected, the Loom Solar Fusion inverter operates largely automatically. It will convert DC power from your solar panels into AC power for your home and the grid.

  • Erstinbetriebnahme: After all connections are verified, switch on the DC isolator and then the AC breaker. The inverter will perform self-tests and begin operation.
  • LED-Anzeige: The front panel features an LED display that provides real-time operational status, power output, and error codes. Refer to the full manual for a detailed explanation of display messages.
  • Fernüberwachung: For detailed performance tracking, connect the inverter to your network using the GPRS/Wifi Kit, WLAN, or Ethernet. Download the Loom Solar mobile application to monitor your system remotely.
Hand holding a smartphone displaying the Loom Solar monitoring app with an inverter in the background.

Figure 3: Remote monitoring via the Loom Solar mobile application.

6. Wartung

Regelmäßige Wartung gewährleistet die Langlebigkeit und optimale Leistung Ihres Solarwechselrichters.

  • Reinigung: Periodically clean the inverter's exterior with a soft, dry cloth. Ensure ventilation openings are free from dust and debris. Do not use liquid cleaners.
  • Sichtprüfung: Regularly check for any visible damage to the casing, cables, or connections.
  • Leistungsüberwachung: Utilize the remote monitoring system to track the inverter's performance and identify any anomalies early.
  • Professioneller Check-up: It is recommended to have a qualified technician perform a comprehensive inspection and maintenance check annually.

7. Fehlerbehebung

This section provides general guidance for common issues. For complex problems, contact Loom Solar customer support.

ProblemMögliche UrsacheLösung
Wechselrichter liefert keinen StromNo sunlight, DC isolator off, AC breaker off, grid outage, error code displayed.Check sunlight conditions. Ensure DC isolator and AC breaker are ON. Verify grid status. Check inverter display for error codes and consult the full manual.
Geringe LeistungsabgabePartial shading on panels, dirty panels, suboptimal weather, system fault.Clear any shading. Clean solar panels. Monitor weather conditions. If issue persists, contact support.
Fehlermeldung auf dem DisplayInternal fault, grid issue, connection problem.Note down the error code. Refer to the detailed error code section in the comprehensive manual or contact Loom Solar support.

8. Spezifikationen

Detailed technical specifications for the Loom Solar Fusion 3kW On-Grid Solar Inverter.

Loom Solar Fusion 31 PV Grid-Tied Inverter Specifications Table

Figure 4: Detailed technical specifications for Fusion 31 inverter.

AttributWert
HerstellerLOOM SOLAR PVT. GMBH.
ArtikelmodellnummerFusion
Produktabmessungen (L x B x H)28 x 18.5 x 31 cm
Artikelgewicht6 kg
Nettomenge1 Anzahl
Generischer NameWechselrichter
MarkeLoom Solar
Empfohlene Verwendung für das ProduktHeim
StromquelleSolarbetrieben
Wastage3000 Watt
ModellnameFusion 31
Max. Eingangsleistung3000 W + 10 %
Max. DC I/P (Vdc)550 V
Max. MPPT Voltage Reichweite70 bis 550 V
Max. Eingangsstrom20 A
AC-Nennleistung3000 W
Nennnetzfrequenz50Hz (±5%)
Rated Grid Voltage230 V
Nennausgangsstrom14.3 Amp
Leistungsfaktor0.8
SchutzartIP65
Umgebungstemperatur bei Betrieb-25°C ~ +65°C

9. Gewährleistung

The Loom Solar Fusion 3kW On-Grid Solar Inverter comes with a 5 Jahre Garantieund gewährleistet so Sicherheit und zuverlässige Leistung.

To log a complaint or register your warranty, please visit the official Loom Solar warranty registration portal:

Registrieren Sie Ihre Garantie hier

10. Unterstützung

For any technical assistance, queries, or support regarding your Loom Solar Fusion inverter, please contact us:

  • Kontakt zum Kundendienst: 8447921124
  • E-Mail: sales@loomsolar.com
  • WebWebsite: www.loomsolar.com
  • Herstelleradresse: LOOM SOLAR PVT. LTD., Plot no. 14/8, Mathura Road, Sector - 27B, Faridabad - 121003

© 2024 Loom Solar. All rights reserved.

Ask a question about this manual