1. Einleitung

This manual provides detailed instructions for the assembly, operation, and maintenance of your Generic 7050 Stereo Trinocular Microscope. This instrument is designed for precise observation and imaging, featuring a 3.5X-50X zoom range, 100X magnification capability, simul-focus optics, and an integrated 24MP 4K camera. Please read this manual thoroughly before use to ensure proper function and longevity of your microscope.

2. Sicherheitshinweise

  • Always handle the microscope with care to prevent damage to optical and mechanical components.
  • Stellen Sie sicher, dass das Mikroskop auf einer stabilen, ebenen Fläche steht, um ein Umkippen zu verhindern.
  • Vor der Reinigung oder Durchführung von Wartungsarbeiten die Stromversorgung unterbrechen.
  • Avoid direct exposure of the eyes to the LED ring light at maximum brightness.
  • Keep the microscope away from dust, moisture, and corrosive chemicals.
  • Do not attempt to disassemble or repair the microscope yourself. Contact support if issues arise.

3. Packungsinhalt

Überprüfen Sie, ob alle unten aufgeführten Komponenten in Ihrem Paket enthalten sind:

  • 1 x Trinocular Stereo Zoom Head
  • 1 x Pair WF10X/22MM Eyepieces
  • 1 x 56-LED Ring Light
  • 1 x Pillar Table Stand
  • 1 x Focusing Rack
  • 1 x Pair of Eye-Guards
  • 1 x Staubschutz
  • 1 x 24MP 4K Camera (with 0.5X Mount Adapter)
  • Optional Auxiliary Objectives (0.5X, 0.7X, 2.0X) and Protection Glass may be included depending on your specific kit.
Generic 7050 Stereo Trinocular Microscope with included accessories

Abbildung 3.1: Überview of the microscope and its main components, including the trinocular head, stand, LED ring light, and various auxiliary lenses and adapters.

4. Einrichtungsanweisungen

  1. Montieren Sie den Ständer: Secure the pillar to the base of the table stand. Ensure it is firmly tightened.
  2. Attach the Focusing Rack: Slide the focusing rack onto the pillar and secure it at a suitable height using the locking screw.
  3. Mount the Trinocular Head: Carefully insert the trinocular stereo zoom head into the focusing rack's mounting ring. Tighten the securing screw to hold the head in place.
  4. Okulare einbauen: Insert the WF10X/22MM eyepieces into the two ocular tubes of the trinocular head. Place the eye-guards over the eyepieces for comfortable viewing.
  5. Attach LED Ring Light: Mount the 56-LED ring light around the objective lens of the microscope head. Connect its power cable to the provided power input.
  6. Install 4K Camera: Attach the 0.5X mount adapter to the 24MP 4K camera. Then, insert the camera assembly into the third (trinocular) port on the microscope head. Secure it with the locking screw.
  7. Strom anschließen: Connect the power adapter to the LED ring light and the camera (if applicable), then plug into a suitable power outlet (100-240V, 50-60HZ).
Nahaufnahme view of the trinocular stereo microscope head

Abbildung 4.1: The trinocular head, showing the eyepiece ports and the third port for camera attachment. Note the zoom adjustment knob on the side.

5. Bedienungsanleitung

5.1 Grundlegende Beobachtung

  1. Platzieren Sie das Exemplar: Position your specimen on the workbench directly under the objective lens.
  2. Beleuchtung anpassen: Turn on the 56-LED ring light and adjust its brightness using the variable intensity control knob to achieve optimal illumination for your specimen.
  3. Interpupillenabstand anpassen: While looking through the eyepieces, adjust the distance between the two eyepiece tubes until you see a single, clear circular field of view.
  4. Fokus: Use the coarse and fine focus knobs on the focusing rack to bring the specimen into sharp focus.
  5. Zoom anpassen: Rotate the zoom knob on the microscope head to change the magnification (0.7X-5X objective zoom, resulting in 7X-50X with WF10X eyepieces). The simul-focus feature maintains focus across the zoom range.
  6. Dioptrieneinstellung: If one eye appears out of focus, use the diopter adjustment ring on one of the eyepieces to compensate for individual eye differences.

5.2 Using the 24MP 4K Camera

The integrated 24MP 4K camera allows for digital imaging and video recording of your observations.

  • Anschluss an das Display: Connect the camera's HDMI output to a compatible monitor or display for live viewing in 4K (3840*2160@30FPS) or Full HD (1920*1080@60FPS).
  • Kamerasteuerung: The camera features buttons for exposure, color adjustment, horizontal/vertical mirroring, picture freezing, taking pictures, and video recording.
  • Messfunktionen: Utilize the basic HDMI 4K output with simple measurement cross hairs. Grid lines (horizontal, vertical, center scale) can be customized in color and thickness for precise measurements.
  • Lagerung: Images (6552*3688 24MP) and videos can be saved to an external storage device (not included, typically via USB or SD card slot if available on the camera unit).
Close-up of the 24MP 4K camera unit with HDMI and Type-C ports

Abbildung 5.1: The 24MP 4K camera unit, highlighting its HDMI output, Type-C port, LED indicator, and control buttons for various camera functions.

6. Wartung

  • Reinigung der Optik: Use a soft, lint-free cloth and a specialized optical cleaning solution to clean eyepiece and objective lenses. Avoid touching optical surfaces with bare hands.
  • Reinigung des Körpers: Wischen Sie das Mikroskopgehäuse mit einem weichen, fusselfreien Tuch ab.amp Tuch. Verwenden Sie keine scharfen Chemikalien oder Scheuermittel.
  • Staubschutz: Always cover the microscope with the provided dust cover when not in use to prevent dust accumulation.
  • Lagerung: Store the microscope in a dry, cool place, away from direct sunlight and vibrations.

7. Fehlerbehebung

  • No Image/Dark Field:
    • Check if the LED ring light is powered on and brightness is adjusted.
    • Ensure the specimen is correctly positioned and in focus.
    • Verify eyepieces are properly seated.
  • Verschwommenes Bild:
    • Adjust the focus knobs (coarse and fine).
    • Clean the eyepieces and objective lenses.
    • Adjust interpupillary distance and diopter settings.
  • Kamera zeigt kein Bild an:
    • Ensure the camera is properly connected to the microscope and the display.
    • Überprüfen Sie die Stromversorgung der Kamera.
    • Verify the display input source is set correctly to HDMI.

8. Spezifikationen

BesonderheitSpezifikation
Kopf360° rotatable, 45° inclined trinocular
OkulareWF10X/22MM (30mm super widefield high-eyepoint)
Objective Zoom Range0.35X-9.0X (with Barlow lenses)
Vergrößerung7X-50X (with WF10X eyepieces)
Arbeitsabstand100 mm (4 Zoll)
Dioptrieneinstellung+/- 5dp
Augenabstand55-75mm (2-3/16" - 2-15/16")
Beleuchtung56-LED Ring Light, 0-100% adjustable brightness
Ring Light Power Input100-240 V, 50-60 Hz
Kamera Sensor1/1.8 IMX377
Effective Camera Pixels24 Millionen
Kameraauflösung3840*2160@30FPS (4K), 1920*1080@60FPS (Full HD)
Picture Pixel6552 x 3688 (24 MP)
AusgabeschnittstelleHDMI
Pixelgröße1.55UM*1.55UM
Kamera-StromversorgungDC-12V / 1A
Artikelgewicht5000 Gramm (11.02 Pfund)
ModellnummerDAVFTATAI

9. Garantie und Support

We are committed to customer satisfaction. For any questions, technical assistance, or support regarding your microscope, please contact our customer service. We strive to answer your questions promptly within 24 hours. Please refer to your purchase documentation for specific warranty terms and contact information.