sako SUNON V 4.5KVA/4200W
SAKO SUNON V 4.5 kVA/4200 W/24 V Hybrid-Solarwechselrichter – Benutzerhandbuch
Model: SUNON V 4.5KVA/4200W
1. Einleitung
Thank you for choosing the SAKO SUNON V 4.5KVA/4200W/24V Hybrid Solar Inverter. This manual provides essential information for the safe and efficient operation of your inverter. This device is designed to provide reliable power for your home or office, integrating solar power, utility power, and battery power to ensure an uninterrupted power supply. It features a high-frequency design, a built-in MPPT solar charge controller, and smart monitoring capabilities.
Bitte lesen Sie diese Anleitung vor der Installation und Inbetriebnahme sorgfältig durch und bewahren Sie sie zum späteren Nachschlagen auf.
2. Sicherheitshinweise
Beachten Sie stets die folgenden Sicherheitsvorkehrungen, um das Risiko von Verletzungen oder Schäden am Wechselrichter zu verringern:
- Qualifiziertes Personal: Installation und Wartung dürfen nur von qualifiziertem Personal durchgeführt werden.
- Belüftung: Sorgen Sie für ausreichende Belüftung rund um den Wechselrichter. Blockieren Sie keine Belüftungsöffnungen.
- Umfeld: Install the inverter in a dry, cool, and dust-free environment, away from flammable materials.
- Elektrische Anschlüsse: All wiring must comply with local and national electrical codes. Ensure all connections are tight and secure to prevent loose connections that can cause overheating.
- Erdung: Der Wechselrichter muss ordnungsgemäß geerdet sein.
- Notfall Abschaltung: Know how to quickly disconnect power to the inverter in an emergency.
- Integrierter Schutz: The inverter includes built-in overload protection, short circuit protection, overvoltage schutz, undervoltage protection, and overtemperature protection to ensure safe operation.
- Batteriesicherheit: When connecting batteries, ensure correct polarity. Batteries can produce explosive gases; ensure proper ventilation in battery areas.
3. Produktüberschreitungview
The SAKO SUNON V Hybrid Solar Inverter is a compact and efficient unit designed for seamless integration into solar energy systems. It features a clear LCD screen for status display and configuration, along with intuitive control buttons.


3.1. Komponenten und Anschlüsse

The inverter features:
- LCD Bildschirm: Displays system status, operational parameters, and error codes.
- Bedientasten: For navigation and setting adjustments on the LCD.
- Radiator/Cooling Fins: Zur Wärmeableitung.
- Ein / Aus Schalter: Hauptleistungssteuerung für den Wechselrichter.
- AC-Eingang: Connection for utility grid power or generator.
- Wechselstromausgang: Connection for household appliances and loads.
- PV-Eingang: Anschlüsse für Solarmodulfelder.
- Battery Terminals (BAT+, BAT-): Anschlüsse für die Batteriebank.
- Kommunikationsanschlüsse: USB, RS485, RS232 for PC monitoring, and Local WiFi for mobile app monitoring.
4. Einrichtung
Proper setup is crucial for the inverter's performance and safety. Ensure all safety guidelines are followed during installation.
4.1. Standortauswahl
- Install indoors, away from direct sunlight, rain, and moisture.
- Ensure ambient temperature is between -10°C to 50°C.
- Um eine ausreichende Luftzirkulation zu gewährleisten, muss ein Mindestabstand von 20 cm um den Wechselrichter herum eingehalten werden.
- Mount on a solid, non-flammable surface.
4.2. Kabelverbindungen
Refer to the following diagram for a typical solar system connection. All wiring should be done by a qualified electrician.

- Batterieanschluss: Connect the 24V battery bank to the BAT+ and BAT- terminals. Ensure correct polarity. The inverter supports working with or without a battery.
- PV-Anlagenanschluss: Schließen Sie die Solarmodulgruppe an die PV-Eingangsklemmen an. Stellen Sie sicher, dass die PV-Spannungtage und Stromstärke liegen innerhalb der Spezifikationen des Wechselrichters.
- AC-Eingangsanschluss: Connect the utility grid power or a compatible generator to the AC INPUT terminals.
- AC-Ausgangsanschluss: Connect your household loads and appliances to the AC OUTPUT terminals.
- Erdung: Schließen Sie den Erdungsanschluss des Wechselrichters an eine zuverlässige Erdung an.
4.3. Erste Inbetriebnahme
- Double-check all wiring connections for tightness and correct polarity.
- Schalten Sie den Batterieschutzschalter ein (falls zutreffend).
- Schalten Sie den Schutzschalter der Solaranlage ein (falls zutreffend).
- Schalten Sie den AC-Eingangsschutzschalter ein (falls zutreffend).
- Finally, turn on the inverter's ON/OFF switch. The LCD screen should light up, indicating the inverter is starting.
5. Betrieb
The SAKO SUNON V inverter offers user-configurable settings and multiple operating modes to optimize your power supply.
5.1. LCD-Display und Einstellungen
The LCD screen provides real-time operational data and allows for system configuration. Use the control buttons below the screen to navigate menus and adjust parameters such as DC/AC input priority, battery type, and charging current.
5.2. Lademodi
The inverter supports four distinct charging modes to suit various energy management needs:

- Solarladung: Prioritizes solar power for charging batteries and powering loads.
- Priorität des Stromversorgungsunternehmens: Prioritizes utility grid power for charging and loads, using solar as a secondary source.
- Priorität für Solarenergie: Prioritizes solar power for loads, using utility power only when solar is insufficient.
- Hybridladung: Combines solar and utility power for optimal charging and load support.
5.3. Smart Monitoring
The inverter features built-in WiFi for remote monitoring and control via a mobile application (Android phones only). It also supports USB, RS485, and RS232 communication for connection to a computer, allowing for detailed parametric analysis and real-time status checks.

Through the app or PC software, users can:
- Monitor system status and energy flow.
- View real-time data and historical performance.
- Receive warning messages and alerts.
- Adjust certain operational parameters remotely.
6. Wartung
Regular maintenance ensures the longevity and optimal performance of your SAKO SUNON V inverter.
- Reinigung: Periodically clean the inverter's exterior, especially the radiator and ventilation openings, to prevent dust buildup that can hinder cooling. Use a soft, dry cloth. Do not use liquid cleaners.
- Verbindungsprüfung: Überprüfen Sie jährlich alle elektrischen Anschlüsse (PV, Batterie, Wechselstrom-Ein-/Ausgang) auf festen Sitz und Korrosionsspuren. Ziehen Sie lose Verbindungen fest.
- Umweltcheck: Stellen Sie sicher, dass die Installationsumgebung innerhalb der vorgegebenen Temperatur- und Feuchtigkeitsbereiche bleibt.
- Batterieinspektion: If using batteries, follow the battery manufacturer's maintenance guidelines. Check battery terminals for corrosion and ensure proper ventilation in the battery area.
- Firmware-Updates: Überprüfen Sie die Angaben des Herstellers webAuf dieser Website finden Sie alle verfügbaren Firmware-Updates, um sicherzustellen, dass Ihr Wechselrichter über die neuesten Funktionen und Fehlerbehebungen verfügt.
7. Fehlerbehebung
This section provides guidance for common issues. For problems not listed or if issues persist, contact technical support.
| Problem | Mögliche Ursache | Lösung |
|---|---|---|
| Der Wechselrichter schaltet sich nicht ein. | Keine Batterieverbindung; Batteriespannungtage too low; Inverter switch off; Loose wiring. | Batterieanschlüsse und Lautstärke prüfentage; Ensure inverter switch is ON; Verify all wiring is secure. |
| Kein AC-Ausgang | Overload; Short circuit; Over-temperature; Battery low; AC output breaker tripped. | Reduce load; Check for short circuits; Allow inverter to cool; Charge battery; Reset AC output breaker. |
| Akku wird nicht geladen | PV input too low/high; AC input not present; Charging current setting too low; MPPT fault. | PV-Anlagenspannung prüfentage/current; Verify AC input; Adjust charging current setting; Contact support if MPPT fault. |
| Das LCD-Display zeigt einen Fehlercode an. | Spezifischer Systemfehler. | Refer to the inverter's specific error code list (if available in separate documentation) for detailed troubleshooting steps. Generally, power cycle the unit and check connections. |
8. Spezifikationen
The following table details the technical specifications for the SAKO SUNON V 4.5KVA/4200W/24V Hybrid Solar Inverter.



| Parameter | Value (SUNON V 4.5KVA/24V) |
|---|---|
| Modellname | SUNON V |
| Nennleistung | 4500 VA/4200 W |
| Batterie Voltage | 24 V Gleichstrom |
| Schwebeladung Voltage | 27 V Gleichstrom |
| Überladeschutz | 33 V Gleichstrom |
| Eingangslautstärketage Reichweite | 230 VAC (Selectable: 170-280VAC for PC; 90-280VAC for Home Appliances) |
| Frequenzbereich | 50 Hz / 60 Hz (automatische Erkennung) |
| AC-Lautstärketage Regulierung (Batt.-Modus) | 230 V Wechselspannung ± 5 % |
| Stoßleistung | 8400VA |
| Wirkungsgrad (Spitze) | 90 % - 93 % |
| Übertragungszeit | 10 ms (für PCs); 20 ms (für Haushaltsgeräte) |
| Wellenform | Reine Sinuswelle |
| Solarladegerättyp | MPPT |
| Maximale PV-Array-Leistung | 5000 W |
| Max. Eingangsstrom | 27 A |
| MPPT-Bereich bei Betriebsvoltage | 60 bis 450 V |
| Max. PV-Array-Leerlaufvoltage | 500 V Gleichstrom |
| Maximaler Solarladestrom | 120 A |
| Maximaler Wechselstrom | 100 A |
| Maximaler Ladestrom | 120 A |
| Packing Dimension (D x W x H) | 583 mm * 380 mm * 214 mm |
| Nettogewicht | 9.6 kg |
| Kommunikationsschnittstelle | USB/RS232/RS485(BMS)/Local WiFi/Dry-contact |
| Luftfeuchtigkeit | 5 % bis 95 % relative Luftfeuchtigkeit (nicht kondensierend) |
| Betriebstemperatur | -10°C bis 50°C |
| Lagertemperatur | -15°C bis 60°C |
9. Garantie und Support
SAKO products are designed for reliability and performance. For warranty information, please refer to the warranty card included with your product or contact your local distributor. Standard warranty terms typically cover manufacturing defects for a specified period from the date of purchase.
Extended warranty options may be available through third-party providers. For exampFür dieses Produkt bietet Salama Care eine einjährige und eine zweijährige Garantieverlängerung an.
For technical support, troubleshooting assistance, or service inquiries, please contact your authorized SAKO dealer or the customer support team. When contacting support, please have your product model number (SUNON V 4.5KVA/4200W) and purchase date ready.