Tunze 6040.005

Tunze Turbelle NanoStream 6040.005 HUB Edition Bedienungsanleitung

Modell: 6040.005

1. Einleitung

This manual provides detailed instructions for the installation, operation, and maintenance of your Tunze Turbelle NanoStream 6040.005 HUB Edition. This high-performance stream pump is designed for aquariums ranging from 20 to 500 liters (5.3 to 132 USgal.), offering adjustable flow rates and smart control capabilities.

The Turbelle NanoStream 6040.005 HUB Edition is equipped with a WIFI/Cloud-based controller (Turbelle Controller 7020) for precise flow management and features a compact design for easy integration into your aquarium.

2. Sicherheitshinweise

  • Always disconnect the power supply before performing any maintenance or installation work on the pump.
  • Ensure the power supply unit is placed in a dry area, away from water splashes.
  • Die Pumpe darf nicht in Betrieb genommen werden, wenn das Netzkabel oder ein Teil des Geräts beschädigt ist.
  • This device is intended for indoor use only and for aquariums.
  • Außerhalb der Reichweite von Kindern aufbewahren.
  • The pump must be fully submerged during operation.

3. Packungsinhalt

Bitte überprüfen Sie, ob alle Artikel im Paket vorhanden sind:

  • Tunze Turbelle NanoStream 6040.005 Pump
  • Turbelle Controller 7020 (WIFI/Cloud-based)
  • Power Supply Unit (100-240V / 50-60Hz)
  • Magnet Holder (for glass thickness up to 12 mm / 1/2”)
  • Strömungsabweiser
  • Bedienungsanleitung

4. Einrichtung und Installation

Follow these steps to properly install your Turbelle NanoStream 6040.005 pump:

4.1. Positioning the Pump

Tunze Turbelle NanoStream 6040.005 pump mounted on aquarium glass with magnet holder

Image: The Turbelle NanoStream 6040.005 pump securely mounted to the aquarium glass using its magnet holder.

  • Ort wählen: Select a position in your aquarium where the pump can create optimal water flow without disturbing substrate or corals excessively. Ensure the pump is fully submerged.
  • Attach Magnet Holder: Place the pump unit inside the aquarium and align the external magnet holder on the outside of the glass. The strong magnets will secure the pump in place. The magnet holder is suitable for glass thicknesses up to 12 mm (1/2 inch).
  • Richtung anpassen: The pump's outlet can be rotated to direct the water flow as desired.

4.2. Anschließen des Controllers

Tunze Turbelle Controller 7020 with various buttons and display for flow control

Image: The Tunze Turbelle Controller 7020, showing its interface for adjusting pump settings and modes.

  • Connect Pump to Controller: Plug the pump's cable into the designated port on the Turbelle Controller 7020.
  • Stromversorgung anschließen: Plug the power supply unit into the controller, then plug the power supply into a suitable electrical outlet.
  • Erstes Einschalten: The pump will perform a brief self-test upon initial power-up.

5. Bedienungsanleitung

The Turbelle NanoStream 6040.005 is controlled via the Turbelle Controller 7020, offering various modes and settings.

5.1. Controller vorbeiview

Tunze Turbelle Controller 7020 with buttons for Food Timer, Manual, Cloud, Analog, Mode, Wave Search, Min Power, Pulse Duration, Max Power

Bild: Detailliert view of the Tunze Turbelle Controller 7020, highlighting its control functions.

The controller allows you to adjust flow rate, set wave patterns, and utilize special functions like the food timer.

5.2. Grundlegende Bedienung

  • Modusauswahl: Use the "Mode" button to cycle through different operating modes (e.g., Constant, Pulse, Wave).
  • Durchflussanpassung: Use the "+" and "-" buttons to increase or decrease the flow rate in Constant mode, or to adjust pulse intensity/duration in other modes.
  • Food Timer: Press the "Food Timer" button to temporarily stop the pump for approximately 10 minutes, allowing fish to feed undisturbed. The pump will automatically resume operation after the timer expires.
  • Wave Search: The "Wave Search" function helps to find the optimal wave frequency for your aquarium.

5.3. WIFI/Cloud Control

The HUB Edition features WIFI/Cloud-based control. Refer to the separate Tunze app manual for detailed instructions on connecting your controller to your home network and managing it remotely via the cloud.

6. Wartung

Regular maintenance ensures optimal performance and longevity of your Turbelle NanoStream pump.

6.1. Cleaning the Pump

Tunze Turbelle NanoStream 6040.005 pump disassembled for cleaning, showing impeller and housing

Image: The Turbelle NanoStream 6040.005 pump, illustrating its components for easy disassembly and cleaning.

  • Stromversorgung trennen: Vor der Reinigung muss die Pumpe immer vom Stromnetz getrennt werden.
  • Remove from Aquarium: Die Pumpe vorsichtig aus dem Aquarium entnehmen.
  • Zerlegen: Gently detach the flow deflector and the protective cage. The impeller can then be carefully removed.
  • Saubere Komponenten: Use a soft brush and warm water to remove algae, calcium deposits, and other debris from all pump components, especially the impeller and its housing. For stubborn deposits, a mild vinegar solution can be used, followed by thorough rinsing.
  • Zusammenbauen: Reassemble the pump in reverse order, ensuring all parts are correctly seated.
  • Frequenz: Clean the pump every 1-3 months, depending on the amount of debris and algae in your aquarium.

6.2. Kabelprüfung

Periodically inspect the power cable for any signs of wear, cuts, or damage. If any damage is found, discontinue use immediately and contact Tunze support.

7. Fehlerbehebung

Hier sind einige häufige Probleme und ihre Lösungen:

ProblemMögliche UrsacheLösung
Pump not starting or weak flow.
  • Keine Stromversorgung.
  • Impeller blocked by debris.
  • Luft in der Pumpe.
  • Controller settings too low.
  • Überprüfen Sie die Stromanschlüsse.
  • Disconnect power, remove pump, clean impeller and housing.
  • Gently shake the pump while submerged to release air.
  • Increase flow setting on the controller.
Pump making unusual noise.
  • Impeller dirty or damaged.
  • Pumpe nicht vollständig eingetaucht.
  • Vibrations against aquarium glass.
  • Clean or inspect impeller for damage. Replace if necessary.
  • Stellen Sie sicher, dass die Pumpe vollständig eingetaucht ist.
  • Adjust pump position or use the included Silence Clamp (if applicable) to reduce vibrations.
Controller antwortet nicht.
  • Problem mit der Stromversorgung.
  • Fehlfunktion der Steuerung.
  • Check power connections to the controller.
  • Try resetting the controller by unplugging and replugging the power. If issues persist, contact support.

8. Spezifikationen

ModellTunze Turbelle NanoStream 6040.005 HUB Edition
Artikelmodellnummer (intern)6095.005
Aquariengröße20 to 500 liters (5.3 to 132 USgal.)
DurchflussrateApprox. 200 to 4,500 l/h (53 to 1,190 USgal./h)
Energieaufnahme1.5 - 13 W
Netzteil100-240V / 50-60Hz
Kabellänge3 m (118 Zoll)
Dimensions (without flow deflector and Magnet Holder)60 x 43 x 68 mm (2.36 x 1.69 x 2.68 Zoll)
Auslassdurchmesserø40 mm (1.57”)
Magnet Holder Glass ThicknessUp to 12 mm (1/2”)
MaterialPlastik
FarbeBlack/Blue/White
Artikelgewicht2.75 Pfund

9. Gewährleistung

The Tunze Turbelle NanoStream 6040.005 HUB Edition comes with a 5 Jahr Garantie from the date of purchase. This warranty covers manufacturing defects and material faults under normal use conditions. Please retain your proof of purchase for warranty claims. The warranty does not cover damage caused by improper installation, misuse, neglect, or unauthorized modifications.

10. Support und Kontaktinformationen

For further assistance, technical support, or warranty inquiries, please contact Tunze customer service or visit the official Tunze webWebsite.

Online-Hilfe: Visit the Tunze Store on Amazon

Bitte halten Sie Ihre Produktmodellnummer (6040.005) und das Kaufdatum bereit, wenn Sie sich an den Support wenden.

© 2024 Tunze. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.