XINJE XC3-24T-E

XINJE XC3-24T-E PLC User Manual

Programmable Logic Controller Instruction Guide

1. Einführung und Endeview

This manual provides comprehensive instructions for the installation, operation, maintenance, and troubleshooting of the XINJE XC3-24T-E Programmable Logic Controller (PLC). The XC3-24T-E is a robust industrial control device designed for various automation tasks, featuring a compact design and versatile connectivity options.

It is equipped with 14 digital inputs (DI) and 10 digital outputs (DO) with transistor output, suitable for AC220V or DC24V power supply systems. This PLC supports advanced programming capabilities and communication protocols, making it an ideal solution for modern industrial automation.

2. Produktmerkmale

  • Integrated 14 Digital Inputs (DI) and 10 Digital Outputs (DO) with Transistor output.
  • Flexible power supply options: AC220V or DC24V.
  • Expandable with additional expansion modules and BD boards for increased I/O or specialized functions.
  • Built-in Real-Time Clock (RTC) for time-based operations.
  • Supports power-off retentive memory, ensuring data integrity during power interruptions.
  • Capable of basic logic control and complex data operations.
  • Advanced functionalities including high-speed counting, pulse output, and exterior interruption handling.
  • Supports C language function blocks for custom programming.
  • Features free switching for I/O points, enhancing configuration flexibility.
  • Supports free protocol communication and standard MODBUS communication for seamless integration with other devices.

3. Einrichtung und Installation

3.1. Stromversorgungsanschluss

The XC3-24T-E PLC supports both AC220V and DC24V power inputs. Ensure the correct voltage is supplied to the designated power terminals. Refer to the wiring diagram on the device for specific terminal assignments. Always disconnect power before making any connections.

3.2. Eingangs-/Ausgangsverdrahtung

Connect your sensors and input devices to the 14 Digital Input (DI) terminals and your actuators and output devices to the 10 Digital Output (DO) transistor terminals. Pay close attention to polarity for DC circuits and ensure proper current ratings are observed for all connected devices.

3.3. Kommunikationsanschlüsse

  • COM 1 (RS-232): Used for connecting to a host machine or Human Machine Interface (HMI) for programming, debugging, and data exchange.
  • COM 2 (RS-485/RS-232): Supports network communication or connection to intelligent instruments, inverters, and other industrial devices.
  • COM 3 (BD Extensional Communication Port RS-232/RS485): An additional port for extending communication capabilities.

3.4. Physische Installation

The PLC can be installed using M3 screws for fixed mounting or by utilizing a DIN46277 (35mm width) guide rail. Ensure the installation location is stable, well-ventilated, and free from excessive vibration or electromagnetic interference.

3.5. Erdung

Proper grounding is crucial for the safe and reliable operation of the PLC. Implement the third type of grounding. Never perform common grounding with a strong power system to prevent electrical hazards and interference.

4. Bedienungsanleitung

4.1. Programming the PLC

The XC3-24T-E supports programming in both instruction list and ladder diagram modes. User programs have a capacity of 8000 steps. Programming is typically performed via the COM 1 (RS-232) port using compatible PLC programming software on a host machine.

4.2. Program Operation Modes

The PLC operates in two primary program modes:

  • Zirkulations-Scanmodus: The PLC continuously scans and executes the user program from start to finish.
  • Zeitabtastmodus: Die Programmausführung wird mit bestimmten Zeitintervallen synchronisiert.

The dispose speed for program execution is approximately 0.5 microseconds, ensuring rapid response times for control applications.

4.3. Data Retention

The PLC utilizes FlashROM for power failure holding, meaning user programs and critical data are retained even if power is lost, ensuring system integrity and minimizing downtime.

4.4. Timers and Counters

The PLC includes a comprehensive set of timers and counters for precise control:

  • Timers (T): 620 points available.
    • 100mS timer: Set time 0.1~3276.7 seconds
    • 10mS timer: Set time 0.01~327.67 seconds
    • 1mS timer: Set time 0.001~32.767 seconds
  • Counters (C): 635 points available.
    • 16-Bit-Zähler: Setze den Wert K0~32767
    • 32-Bit-Zähler: Setze den Wert K0~2147483647

Data Registers (D) provide 8512 characters for storing operational data.

5. Wartung

To ensure the longevity and reliable operation of your XINJE XC3-24T-E PLC, adhere to the following maintenance guidelines:

  • Umgebungsbedingungen: The PLC is designed to operate within an environment temperature range of 0°C to 6°C and an ambient humidity of 5% to 95% (non-condensing). Operating outside these ranges may affect performance and lifespan.
  • Reinigung: Regularly clean the exterior of the PLC with a soft, dry cloth. Avoid using abrasive cleaners or solvents. Ensure ventilation openings are free from dust and debris to prevent overheating.
  • Verbindungsprüfungen: Periodically inspect all wiring connections to ensure they are secure and free from corrosion. Loose connections can lead to intermittent operation or system failures.
  • Firmware-Updates: Überprüfen Sie die Angaben des Herstellers website for any available firmware updates that may improve performance or address known issues. Follow update procedures carefully.
  • Stabilität der Stromversorgung: Ensure a stable and clean power supply. Fluctuations or noise in the power supply can impact PLC operation.

6. Fehlerbehebung

This section provides general guidance for common issues. For complex problems, consult the XINJE technical support or a qualified technician.

6.1. Kontrollleuchten

Observe the status indicator lights on the PLC front panel:

  • PWR (Leistung): Should be steadily lit when power is supplied correctly. If off, check power connections and source.
  • LAUF: Indicates the PLC is in run mode and executing the program. If off or blinking, the PLC may be in stop mode or encountering an issue.
  • ERR (Fehler): If lit, an internal error or program error has occurred. Refer to the programming software for detailed error codes and diagnostics.

6.2. Häufige Probleme

  • SPS schaltet sich nicht ein: Überprüfen Sie die Lautstärke der Stromversorgungtage matches the PLC's requirements (AC220V or DC24V). Check all power wiring for secure connections and continuity.
  • Eingaben reagieren nicht: Check wiring to input devices. Ensure sensors are correctly powered and functioning. Verify input addresses in the PLC program match physical connections.
  • Ausgänge werden nicht aktiviert: Check wiring to output devices. Ensure actuators are correctly powered and functioning. Verify output addresses and logic in the PLC program. Check for overload or short circuits on output terminals.
  • Kommunikationsprobleme: Verify cable connections (RS-232/RS-485). Ensure communication parameters (baud rate, data bits, parity, stop bits) are correctly configured in both the PLC and the connected device (e.g., HMI, PC).
  • Programmfehler: If the ERR light is on, connect to the PLC with programming software to identify the specific error. Common errors include syntax errors, logic faults, or memory issues.

7. Spezifikationen

KategorieArtikelTechnische Daten
AllgemeinIsolierung VoltageÜber DC 500V 2Mohm
Geräuschbeständigkeit1000 V, 1 µs Impuls für 1 Minute
Umgebungstemperatur0°C ~ 6°C
Luftfeuchtigkeit5 % – 95 % (nicht kondensierend)
InstallationM3-Schraubbefestigung oder Montage mit DIN46277 (35 mm Breite) Führungsschiene
ErdungThe third type grounding (Never perform common grounding with strong power system)
LeistungProgrammbetriebsmodusUmlauf-Scanmodus, Zeit-Scanmodus
Programm-ModusAnleitung und Leiterdiagramm
Dispose Speed0.5us
Stromausfall-HaltestelleFlashROM
Benutzerprogrammkapazität8000 Schritte
E/A-Punkte14 Eingangspunkte, 10 Ausgangspunkte
AusgabeformatTransistor
StromversorgungAC220V/DC24V
Innenliegende Zündspulenkontakte (M)8512 Punkte
Zeitpunkte (T)620 Punkte
Timer (T) Specification100-ms-Timer: Einstellzeit 0.1 bis 3276.7 Sekunden
10-ms-Timer: Einstellzeit 0.01 bis 327.67 Sekunden
1-ms-Timer: Einstellzeit 0.001 bis 32.767 Sekunden
Gegenpunkte (C)635 Punkte
Counter (C) Specification16-Bit-Zähler: Setze den Wert K0~32767
32-Bit-Zähler: Setze den Wert K0~2147483647
Datenregister (D)8512 Zeichen

8. Produktbilder

XINJE XC3-24T-E PLC angled view

Abbildung 8.1: Schräg view of the XINJE XC3-24T-E PLC, showing the input/output terminals and status indicators.

XINJE XC3-24T-E PLC top view

Abbildung 8.2: Draufsicht view of the XINJE XC3-24T-E PLC, highlighting the terminal blocks and model labeling.

XINJE XC3-24T-E PLC with retail packaging

Figure 8.3: The XINJE XC3-24T-E PLC alongside its retail packaging, showing the product box and included documentation.

9. Garantie und Support

Specific warranty terms and detailed support contact information for the XINJE XC3-24T-E PLC are not available in the provided product data. For warranty claims, technical assistance, or further inquiries, please refer to the documentation included with your purchase or contact the vendor or manufacturer directly.

It is recommended to retain your proof of purchase for any warranty-related matters.

© 2024 XINJE. All rights reserved.