ZAMEL RTP-04

Programmable Temperature Controller RTP-04

Model: RTP-04 | Brand: ZAMEL

1. Produktüberschreitungview

The ZAMEL RTP-04 is a programmable temperature controller designed for flush-mounted installation. It is compatible with electric underfloor heating systems and offers precise temperature regulation using either an external floor sensor, an internal sensor, or a combination of both, along with a floor temperature limiting function.

ZAMEL RTP-04 Programmable Temperature Controller with LCD display showing 23.0°C and 24.4°C, and control buttons.

Abbildung 1: Vorderseite view of the ZAMEL RTP-04 Programmable Temperature Controller, displaying current and set temperatures on its clear LCD screen, with power, mode, and adjustment buttons below.

2. Hauptmerkmale

  • Klares LCD-Display: Features large characters and uniform white backlighting for easy readability.
  • Umfassende Funktionalität: Displays time, current operating program, and temperature readings from either the internal or external sensor.
  • Erhöhte Sicherheit: Includes overheating protection and an anti-frost function to prevent damage and ensure consistent operation.
  • Flexible Programmierung: Supports 5+2 and 6+1 modes with 6 distinct time intervals for customized heating schedules.
  • Intuitive Steuerung: User-friendly menu interface available in English for straightforward operation.

3. Einrichtung

3.1. Installation

The RTP-04 is designed for flush-mounted installation within a standard 60 mm flush-mounted box. Ensure all electrical connections are made by a qualified electrician in accordance with local wiring regulations.

  • Turn off the main power supply before beginning installation.
  • Mount the controller securely into the flush-mounted box.
  • Connect the power supply, heating element, and external floor sensor (if used) to the appropriate terminals as indicated in the wiring diagram (refer to the full wiring diagram provided in the product packaging).
  • Secure the front panel and restore power.

3.2. Erstes Einschalten

Upon first power-on, the display will illuminate. You may need to set the current time and date before proceeding with programming.

4. Bedienungsanleitung

4.1. Informationen anzeigen

The LCD display shows the current room temperature, the set temperature, the current time, and the active operating program. A small thermometer icon indicates the sensor currently in use (internal or external).

4.2. Tastenfunktionen

SchaltflächensymbolFunktion
(Kraftsymbol)Ein-/Ausschalten
MMode Selection / Menu Access
(Pfeil nach oben)Increase Value / Navigate Up
(Pfeil nach unten)Decrease Value / Navigate Down
(Snowflake/Fan Symbol)Frost Protection / Fan Mode (if applicable)

4.3. Programmiermodi

The RTP-04 offers flexible programming with 5+2 and 6+1 modes, allowing you to set different temperature schedules for weekdays and weekends, or for a single weekend day. Each mode supports up to 6 time intervals per day.

  • 5+2-Modus: Allows one schedule for Monday-Friday and a separate schedule for Saturday-Sunday.
  • 6+1-Modus: Allows one schedule for Monday-Saturday and a separate schedule for Sunday.
  • Intervalle einstellen: Use the 'M' button to enter programming mode, then use the arrow buttons to adjust time and temperature for each interval. Confirm settings to save.

4.4. Temperaturregelung

The controller can regulate temperature based on an internal sensor, an external floor sensor, or both. The floor temperature limiting function prevents the floor from overheating, protecting both the heating system and the floor covering.

5. Wartung

  • Reinigung: Wischen Sie das Display ab und casinMit einem weichen, trockenen Tuch abwischen. Keine Scheuermittel oder Lösungsmittel verwenden.
  • Sensorpflege: Ensure the external floor sensor (if installed) is free from obstructions and debris to ensure accurate readings.
  • Keine vom Benutzer zu wartenden Teile: Versuchen Sie nicht, das Gerät selbst zu öffnen oder zu reparieren. Wenden Sie sich für Reparaturen an qualifiziertes Servicepersonal.

6. Fehlerbehebung

  • Anzeige funktioniert nicht: Check the main power supply. Ensure the controller is properly installed and connected.
  • Falsche Temperaturanzeige: Verify that the sensor is correctly connected and not damaged. Ensure the sensor is placed appropriately for accurate measurement.
  • Heizung aktiviert sich nicht: Check the set temperature to ensure it is above the current room temperature. Verify the operating mode and schedule. Ensure the heating element is functioning correctly.
  • Programmierprobleme: Refer to the detailed programming instructions in the full user manual. Ensure all steps are followed correctly.

If problems persist, contact ZAMEL customer support or a qualified technician.

7. Spezifikationen

AttributWert
Produktabmessungen (L x B x H)18 x 4 x 4 cm
Gewicht26 Gramm
Reference / Model Number1 (RTP-04)
ASINB0F141YCGL
Datum der Erstveröffentlichung auf Amazon.fr27. März 2025
FarbeWeiß
MarkeZAMEL
HerstellerZamel
Verfügbarkeit von ErsatzteilenInformationen nicht verfügbar

8. Garantie und Support

Specific warranty information for the ZAMEL RTP-04 Programmable Temperature Controller is not available in the provided product data. For detailed warranty terms and conditions, please refer to the documentation included with your product or visit the official ZAMEL webWebsite.

For technical support, troubleshooting assistance beyond this manual, or inquiries about spare parts, please contact ZAMEL customer service directly. Contact information can typically be found on the manufacturer's webWebsite oder in der Produktverpackung.

Always ensure that any repairs or installations are carried out by qualified professionals to maintain product safety and validity of any potential warranty.

© 2025 ZAMEL. All rights reserved. This manual is for informational purposes only.