BSIDE O1 Green

BSIDE Handheld Oscilloscope Multimeter O1 Green User Manual

Model: O1 Green | Brand: BSIDE

Einführung

The BSIDE O1 Green Handheld Oscilloscope Multimeter is a versatile 2-in-1 device designed for comprehensive electrical testing. It combines the functionalities of a true RMS digital multimeter with a graph scope, making it suitable for various applications including HVAC, electronics, and automotive maintenance. Featuring a clear 2.8-inch TFT LCD color display, it provides accurate measurements and waveform visualization.

BSIDE O1 Green 2-in-1 Oscilloscope Multimeter

Image: The BSIDE O1 Green device, highlighting its dual functionality as both a multimeter and an oscilloscope.

Lieferumfang

Your BSIDE O1 Green package includes the following components:

  • 1 x Handheld Oscilloscope Multimeter
  • 1 x Messleitungen
  • 1 x Tragetasche
  • 1 x Ladekabel
  • 1 x Benutzerhandbuch
Contents of the BSIDE O1 Green package

Image: All items included in the product package: the oscilloscope multimeter, test leads, carrying case, and charging cable.

Aufstellen

Aufladen des Geräts

The BSIDE O1 Green is equipped with a rechargeable battery. Before first use, or when the low battery indicator appears, connect the device to a power source using the provided charging cable. The charging port is located under a protective cover on the device.

Charging the BSIDE O1 Green Oscilloscope Multimeter

Image: The device connected to a charging cable, illustrating the charging process.

Anschließen der Messleitungen

Insert the red test lead into the "INPUT" or "VΩ" jack and the black test lead into the "COM" jack for most measurements. For current measurements, use the "10A FUSED" or "6A" jack for the red lead, depending on the expected current range.

Bedienungsanleitung

Allgemeine Bedienung

The device features a 2.8-inch color TFT screen for clear display of measurements and waveforms. Use the navigation buttons (up, down, left, right) and the 'AUTO' and 'FUNC' buttons to navigate menus and select modes.

BSIDE O1 Green 2.8 inch TFT Color Display

Bild: Eine Nahaufnahme view of the device's 2.8-inch TFT color display, showing both oscilloscope and multimeter readings.

Multimeter-Modus

In Multimeter Mode, the device functions as a true RMS digital multimeter. It can measure a variety of electrical parameters:

  • Bandtage: AC- und DC-Voltage-Messung.
  • Aktuell: AC and DC current measurement (up to 10A).
  • Widerstand: Misst den elektrischen Widerstand.
  • Kapazität: Misst Kapazitätswerte.
  • Diode: Tests diodes within 3V.
  • Kontinuität: Checks for circuit continuity with an audible alert.
  • V-Alert (Non-Contact Voltage Erkennung): Erkennt AC-Voltage ohne direkten Kontakt.
  • Prüfung stromführender Leitungen: Identifiziert stromführende Leitungen.
  • MAX/MIN/AVG: Displays maximum, minimum, and average values during measurements.

To switch between measurement functions within Multimeter Mode, press the FUNK Schaltfläche. Die AUTO button enables auto-ranging for most measurements.

Oszilloskopmodus

The Oscilloscope Mode allows for waveform visualization and analysis. Key features include:

  • Bandbreite: 10MHz.
  • Echtzeit-SampPreis: 48 MSa/s.
  • Automatische Kalibrierung: Gewährleistet genaue Messwerte.
  • Speicherfunktion: Stores waveform data.
  • Horizontal SEC Range: 100ns/div - 20s/div.
  • Vertikale Empfindlichkeit: 20mV/div - 100V/div.

Use the navigation buttons to adjust the time base, voltage division, and trigger settings. The AUTO button can automatically set optimal display parameters for the input signal.

BSIDE O1 Green Waveform Measurement

Bild: Examples of various waveforms displayed on the oscilloscope screen, demonstrating its measurement capabilities.

Datenspeicherung und -export

The device supports data storage, allowing you to save measured data and waveforms. This data can then be exported to your computer for further analysis or record-keeping.

BSIDE O1 Green Efficient Data Storage and Export

Image: The device displaying saved data, with icons indicating its data storage and export capabilities to a computer.

Integrierte Taschenlampe

For convenience in low-light conditions, the device includes a bright LED flashlight. This can be activated via a dedicated button or menu option.

BSIDE O1 Green Bright LED Flashlight

Image: The device with its integrated LED flashlight illuminated, demonstrating its utility in dark environments.

Produktdemonstrationsvideo

Watch this official product video for a demonstration of the BSIDE O1 Scope Multimeter's features and operation.

Video: A demonstration of the BSIDE O1 Scope Multimeter, showcasing its various measurement capabilities including voltage, resistance, continuity, and waveform display.

Wartung

Batteriepflege

The device uses a rechargeable Lithium Ion battery. To ensure optimal battery life, charge the device regularly and avoid fully discharging it for extended periods. Always use the provided charging cable.

Reinigung und Lagerung

Clean the device with a soft, dry cloth. Avoid using abrasive cleaners or solvents. Store the multimeter in its provided carrying case to protect it from dust, moisture, and physical damage when not in use.

Servicefreundlichkeit

The device is designed for serviceability. The case uses screws, and components such as the fuse and LiPo battery can be replaced without desoldering, if necessary. For complex repairs, it is recommended to contact qualified service personnel.

Fehlerbehebung

If you encounter issues with your BSIDE O1 Green, consider the following common troubleshooting steps:

  • Gerät lässt sich nicht einschalten: Stellen Sie sicher, dass der Akku geladen ist. Schließen Sie das Ladekabel an und lassen Sie den Akku mindestens 30 Minuten lang laden, bevor Sie das Gerät erneut einschalten.
  • Ungenaue Messwerte: Check that the test leads are properly connected to the correct jacks for the measurement type. Ensure the probes are making good contact with the circuit. Perform an auto-calibration if available in the device settings.
  • Anzeigeprobleme: If the screen is dim or unreadable, adjust the brightness settings. If the display is frozen, try restarting the device.
  • Im Oszilloskopmodus wird keine Wellenform angezeigt: Verify that the input signal is within the device's bandwidth and voltage range. Adjust the time base and vertical sensitivity settings. Ensure the trigger is set appropriately.

For persistent issues, refer to the detailed user manual included in the package or contact BSIDE customer support.

Technische Daten

BesonderheitSpezifikation
MAX-Anzeige6000 Zählwerte
Bildschirmgröße2.8 Zoll
Bandbreite10 MHz
Echtzeit-SampPreis48 MSa / s
Eingangsimpedanz1MΩ, @16pf
Maximale Eingangslautstärketage300 V (DC + AC Spitze)
Horizontaler SEC-Bereich100 ns/div - 20 s/div
Vertikale Empfindlichkeit20 mV/div - 100 V/div
DC-Voltage60mV (0.01mV ±(1%+5)); 600mV/6V/60V (0.1mV/0.001V/0.01V/ ±(0.8%+3)); 600V (0.1V ±(1%+5))
AC-Lautstärketage60mV (0.01mV ±(1.2%+5)); 600mV/6V/60V (0.1mV/0.001V/0.01V/ ±(1%+3)); 600V (0.1V ±(1.2%+5))
Gleichstrom6A/10A (0.001A/0.01A ±(1.2%+3))
Wechselstrom6A/10A (0.001A/0.01A ±(1.2%+3))
Widerstand600Ω (0.1Ω ±(1.2%+5)); 6kΩ/60KΩ/600KΩ (0.001KΩ/0.01KΩ/0.1KΩ ±(1.0%+3)); 6MΩ (0.001MΩ ±(1.2%+5)); 60MΩ (0.01MΩ ±(1.5%+5))
Kapazität99.99nF (0.01nF ±(5.0%+20)); 999.9nF/9.999µF/99.99µF/999.9µF (0.1nF/0.001µF/0.01µF/0.1µF ±(4.5%+5)); 9.999mF/99.99mF (0.001mF/0.01mF ±(5.0%+10))
DiodeMeasures diodes within 3V
KontinuitätJa
V-Alert (non-contact voltage-Erkennung)Ja
Leistung2000mA battery (rechargeable)
Größe187 x 74 x 40.5 mm
Gewicht269g

Garantie und Support

For warranty information and technical support, please refer to the documentation included with your product or contact BSIDE customer service directly. Keep your purchase receipt as proof of purchase for any warranty claims.

Die Kontaktdaten des Kundendienstes finden Sie in der Regel auf der offiziellen Website des Herstellers. weboder über den Einzelhändler, bei dem das Produkt gekauft wurde.

© 2024 BSIDE. Alle Rechte vorbehalten.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.