OOYCYOO 60A 48V 36V 24V 12V

OOYCYOO 60A MPPT Solar Charge Controller User Manual

Model: 60A 48V 36V 24V 12V

1. Einleitung

The OOYCYOO 60A MPPT Solar Charge Controller is an advanced device designed to efficiently manage power flow from your solar panels to your battery bank. Utilizing Maximum Power Point Tracking (MPPT) technology, it optimizes solar energy harvesting, ensuring rapid and efficient charging for various battery types including lead-acid (Sealed, Gel, Flooded) and Lithium (LFP) batteries across 12V, 24V, 36V, and 48V systems. This controller features a clear LCD display for monitoring system status and multiple safety protections to ensure reliable operation.

OOYCYOO 60A MPPT Solar Charge Controller with LCD display and labeled terminals

Abbildung 1: Vorderseite view of the OOYCYOO 60A MPPT Solar Charge Controller, highlighting the LCD display and connection terminals.

2. Hauptmerkmale

  • 60A MPPT Charging Controller: Verfügt über ein 4-stage battery charging algorithm (Bulk Charge, Boost Charge, Float Charge, and Equalization) for rapid, efficient, and safe charging.
  • Breites Volumentage/Power-Unterstützung: Supports high PV input power and voltage. The controller can accept solar voltage up to 160V. Recommended solar power: 720W for 12V systems, 1440W for 24V, 2100W for 36V, and 2800W for 48V.
  • Kompatibilität mit mehreren Akkus: Compatible with various battery types including lead-acid (Sealed, Gel, Flooded) and Lithium (LFP) batteries. Charging parameters are pre-set and user-definable.
  • High Tracking Efficiency: Advanced Maximum Power Point Tracking technology ensures continuous tracking of the array’s maximum power point, achieving tracking efficiency of not less than 98.1% and peak conversion efficiency up to 98%.
  • Doppeltes Kühlsystem: Constructed with die-cast aluminum for excellent heat dissipation. Includes a built-in cooling fan that activates when the temperature exceeds 45°C and turns off below 40°C, extending product life up to 5000 hours in normal use.
  • Verbesserte Sicherheitsvorkehrungen: Includes protection against PV overcurrent/power, PV short circuit, PV reverse polarity, night reverse charging, battery reverse polarity, battery over voltage, battery over discharge, battery overheating, controller overheating, lithium battery low temperature, load short circuit, load overload, and TVS high voltage Transienten.
Diagram showing multiple protection features of the solar charge controller

Abbildung 2: Überview of the controller's comprehensive safety protection features.

3. Einrichtung und Installation

Proper installation is crucial for the safe and efficient operation of your solar charge controller. Always ensure all power sources are disconnected before making any connections.

3.1 Anschlussreihenfolge

  1. Schließen Sie die Batterie an: First, connect the battery to the controller's battery terminals. Ensure correct polarity (+ to + and - to -). The controller will automatically detect the battery voltage.
  2. Schließen Sie die Solarpaneele an: Next, connect the solar panel array to the controller's PV terminals. Ensure correct polarity. The controller will begin charging the battery.
  3. Gleichstromlast anschließen (optional): Finally, connect your DC load to the load terminals. Do not exceed the maximum rated current for the load output.

Important: Always connect the battery first and disconnect the solar panels first when disassembling the system.

Diagram showing the connection of solar panels, battery, and DC load to the MPPT solar charge controller

Figure 3: System wiring diagram for the solar charge controller, illustrating connections to solar panels, battery, and DC load.

3.2 Installationsvideoanleitung

Eine visuelle Anleitung zum Installationsprozess finden Sie im folgenden Video:

Video 1: Quick installation guide for a 60A MPPT solar charge controller, demonstrating battery and photovoltaic input cable connections.

4. Bedienung

The controller features an LCD display and control buttons for monitoring and adjusting settings.

4.1 LCD-Display und Tasten

The LCD display provides real-time information on system status, including battery voltage, charging current, and load status. Use the 'SET' button to enter settings mode and the 'A', 'B', 'C', 'D' buttons (or similar navigation buttons) to adjust parameters. A 5-second press on the 'SET' button typically initiates a reset or enters advanced settings.

Diagram showing battery adaptability and charging curve for various battery types

Figure 4: Illustration of the controller's strong battery adaptability, supporting GEL, AGM, User, SEL, FLD, LI, and LiFePO4 battery types, along with a typical 4-stage Ladekurve.

4.2 Battery Type and System Voltage Einstellungen

The controller automatically identifies 12V, 24V, 36V, or 48V battery systems. You can select the specific battery type (e.g., Sealed, Gel, Flooded, Lithium) and customize charging parameters if needed. Refer to the specifications table for default values.

Table of original values for 12V, 24V, and 48V systems, including float voltage, Untervoltage protection, and maximum input power

Figure 5: Table detailing default and adjustable parameters for 12V, 24V, and 48V battery systems, including float voltage, Untervoltage protection, and maximum solar panel input power.

4.3 Operation Video Guides

Explore the operational aspects of the solar charge controller with these video guides:

Video 2: Ein überview of the MPPT Solar Charging Controller (80A model shown), demonstrating its features and basic operation.

Video 3: Detailed operation of an Ampinvt solar charge controller, covering display navigation and settings adjustments.

Video 4: An instructional video on the CM Series solar charge controller, demonstrating how to navigate settings and understand display information.

5. Wartung

To ensure the longevity and optimal performance of your OOYCYOO MPPT Solar Charge Controller, follow these maintenance guidelines:

  • Regelmäßige Inspektion: Überprüfen Sie regelmäßig alle Kabelverbindungen auf festen Sitz und Korrosion. Stellen Sie sicher, dass keine Kabel ausgefranst oder beschädigt sind.
  • Sauberkeit: Keep the controller clean and free from dust and debris. Use a dry cloth to wipe the exterior. Do not use liquids or solvents.
  • Belüftung: Ensure the cooling vents are unobstructed to allow for proper airflow. The built-in fan will operate automatically to dissipate heat.
  • Batteriezustand: Monitor your battery bank's health regularly. Ensure batteries are properly maintained according to their manufacturer's recommendations.

6. Fehlerbehebung

This section outlines common issues and their potential solutions. The controller is equipped with multiple protection functions to prevent damage.

Issue/Protection TriggeredMögliche UrsacheLösung
PV-Überstrom/-LeistungSolar panel input power or current exceeds controller limits.Reduce the number of solar panels or ensure total PV power is within specifications.
PV-KurzschlussShort circuit in the solar panel wiring.Inspect solar panel wiring for damage or incorrect connections and rectify.
PV VerpolungSolar panel positive and negative terminals are reversed.Disconnect solar panels and reconnect with correct polarity.
Verpolung der BatteriePlus- und Minuspol der Batterie sind vertauscht.Disconnect battery and reconnect with correct polarity.
Akku über VoltageAkku voltage überschreitet das eingestellte Übervoltage Schutzpunkt.Check battery type settings; ensure battery is not faulty.
Batterie-ÜberentladungAkku voltage drops below the set over-discharge protection point.Reduce load, charge battery, or check battery health.
Überhitzung des ControllersInternal temperature of the controller is too high.Ensure adequate ventilation around the controller. Check if the cooling fan is operating. Reduce load if necessary.
LastkurzschlussShort circuit in the DC load wiring.Inspect load wiring for damage or incorrect connections and rectify.
Überlast ladenConnected DC load exceeds the controller's maximum load current.Reduce the total power of the connected DC loads.

7. Technische Daten

ParameterWert
Nennladestrom60 A
System-Nennvolumentage12V/24V/36V/48V DC Automatische Erkennung
max. PV Leerlauf Voltage160 V Gleichstrom
Maximale PV-Eingangsleistung (12-V-System)720 W
Maximale PV-Eingangsleistung (24-V-System)1440 W
Maximale PV-Eingangsleistung (36-V-System)2100 W
Maximale PV-Eingangsleistung (48-V-System)2800 W
Batterie Voltage Reichweite9 V bis 55 V
Drahtstärke der Stromanschlussklemme6-12AWG
Abmessungen (L x B x H)27.9L x 27.9W x 6.4H Centimetres (11 x 6 x 2.5 inches)
MaterialAluminiumdruckguss
AnzeigetypLCD
Tracking-Effizienz≥ 98.1 %
Maximaler UmwandlungswirkungsgradBis zu 98%

8. Garantieinformationen

Specific warranty details for the OOYCYOO 60A MPPT Solar Charge Controller are not provided in this manual. Please refer to the product packaging, the retailer's website, or contact the manufacturer directly for warranty terms and conditions.

9. Unterstützung und Kontakt

For further assistance, technical support, or to access additional resources, please refer to the manufacturer's official website or contact their customer service. You may also find additional information by scanning the QR code often found on the product or packaging.

A relevant link for additional information or support may be found at: http://qr61.cn/oQXA1T/qsECN8r

Seite view of the OOYCYOO MPPT Solar Charge Controller showing CE, FC, RoHS marks and a QR code

Abbildung 6: Seite view of the controller, displaying regulatory compliance marks and a QR code for additional information.

© 2026 OOYCYOO. Alle Rechte vorbehalten.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.