Anderic MRAC06S1M
Anderic MRAC06S1M Ceiling Fan Receiver Instruction Manual
Model: MRAC06S1M
Produkt überview
The Anderic MRAC06S1M is a replacement ceiling fan receiver specifically designed for use with Harbor Breeze Mazon ceiling fans. This receiver facilitates the remote control functionality of your ceiling fan, managing fan speeds and light operation. It is engineered for a plug-and-play installation, connecting directly into the fan's motor assembly via a square plug connector.
This receiver is compatible with various Harbor Breeze Mazon models, including 0807421, 2599776, 1059534, MZ44WW3LR, MZ44MBLK3LR, and others. It also works seamlessly with existing Anderic remote models such as RRTR214D, A25-FA0138, KUJCE10311, TR214B, KUJCE10712, TR214A, KUJCE10610, and 2BB78ITLF304C.
Wichtige Sicherheitsinformationen
- Always disconnect power to the ceiling fan at the circuit breaker before attempting any installation, maintenance, or troubleshooting.
- Installation should be performed by a qualified electrician or a person with sufficient electrical knowledge to ensure safety and proper function.
- Stellen Sie sicher, dass alle Kabelverbindungen sicher und ordnungsgemäß isoliert sind.
- This receiver is designed for specific fan models and connector types. Verify compatibility before installation. If your fan uses standard wire connections at the canopy, this receiver will not be compatible for plug-and-play installation.
- Do not exceed the maximum load ratings for the motor (1.0A) and light (100W incandescent / 60W LED).
Packungsinhalt
- Anderic MRAC06S1M Ceiling Fan Receiver (1 unit)
- Bedienungsanleitung (dieses Dokument)
Note: Remote control is not included and must be purchased separately if needed. This receiver is designed to work with existing compatible remotes.
Setup und Installation
The Anderic MRAC06S1M receiver is designed for a straightforward plug-and-play installation into compatible Harbor Breeze Mazon ceiling fans. Ensure your fan's existing receiver uses a square plug connector for direct replacement.
Checkliste vor der Installation:
- Verify that your ceiling fan model is listed as compatible or uses a square plug connector for its receiver.
- Ensure you have the necessary tools (e.g., screwdriver, wire strippers if any wiring adjustments are needed, though typically not for plug-and-play).
- Confirm power is OFF at the circuit breaker before proceeding.
Installationsschritte:
- Stromversorgung trennen: Turn off the power to the ceiling fan at the main circuit breaker. Verify power is off using a voltage Tester.
- Zugang zum Lüftergehäuse: Carefully lower the canopy or access the motor housing of your ceiling fan where the existing receiver is located.
- Alten Empfänger entfernen: Disconnect the existing receiver from the fan's wiring. Note the orientation and connection points if possible, though the square plug design simplifies this.
- Install New Receiver: Connect the Anderic MRAC06S1M receiver into the fan's motor assembly. The square plug connector should fit directly into the corresponding port. Ensure it is seated firmly.
- Sicherer Empfänger: Carefully tuck the receiver and wires back into the fan housing, ensuring no wires are pinched.
- Strom wiederherstellen: Replace the fan canopy and turn the power back on at the circuit breaker.
- Testfunktionalität: Use your compatible remote control to test the fan speeds and light operation.

Abbildung 1: Vorderseite view of the Anderic MRAC06S1M receiver, showing its compact design and integrated wiring with the square plug connector.

Abbildung 2: Schräg view of the receiver, clearly showing the distinctive square plug connector essential for plug-and-play compatibility with Harbor Breeze Mazon fans.

Abbildung 3: Zurück view of the receiver, displaying the product label with model number MRAC06S1M-LD-F0, input voltage (AC120V 60Hz), and maximum load ratings for motor and light.

Abbildung 4: Seite view of the receiver, showing the capacitor specifications (5+6UF/250V) and a QC Pass sticker, indicating quality control inspection.
Wichtiger Hinweis zur Kompatibilität:
This receiver is designed for fans where the receiver connects directly into the motor assembly with a square plug. If your existing receiver connects at the canopy with standard wire connections (individual wires that need to be spliced or connected via wire nuts), this MRAC06S1M receiver will nicht be a plug-and-play replacement and may not be compatible without significant modification.
Bedienungsanleitung
Once the Anderic MRAC06S1M receiver is correctly installed, it will enable remote control functionality for your ceiling fan. This receiver is designed to work with specific Anderic and compatible remote models.
Compatible Remote Controls:
The MRAC06S1M receiver is fully compatible with the following remote control models:
- Anderic RRTR214D
- A25-FA0138
- KUJCE10311
- TR214B
- KUJCE10712
- TR214A
- KUJCE10610
- 2BB78ITLF304C
Note: The TR214D remote control is often required for initial pairing or full functionality and is not included with the receiver.
Pairing the Remote (if necessary):
Most compatible remotes will automatically pair or have a simple pairing procedure. Refer to your specific remote control's instruction manual for detailed pairing steps. Typically, this involves:
- Ensure power to the fan is on.
- Within a short timeframe (e.g., 30 seconds) of restoring power, press and hold a specific button on the remote (often a "Learn" button, "Fan Off" button, or a combination of buttons) until the fan light blinks or the fan responds.
- Test all functions (fan speeds, light on/off, dimming if applicable).
Wartung
The Anderic MRAC06S1M receiver is a sealed electronic component and requires minimal maintenance. Follow these guidelines to ensure its longevity:
- Trocken halten: Ensure the receiver is installed in a dry environment, protected from moisture and humidity.
- Sauberkeit: If accessing the receiver during fan maintenance, gently wipe away any dust or debris with a dry, soft cloth. Do not use liquid cleaners.
- Belüftung: Ensure the fan housing allows for adequate airflow around the receiver to prevent overheating.
- Stromstöße: Consider using surge protection for your home's electrical system to protect electronic components like the receiver from power fluctuations.
Fehlerbehebung
If you experience issues with your ceiling fan after installing the MRAC06S1M receiver, refer to the following common problems and solutions:
Problem: Fan or Light Does Not Respond to Remote
- Kein Strom: Check the circuit breaker to ensure power is supplied to the fan.
- Fernbedienungsbatterien: Replace the batteries in your remote control.
- Remote-Kopplung: Attempt to re-pair the remote control with the receiver. Refer to the "Operating Instructions" section or your remote's manual.
- Incorrect Remote: Ensure you are using a compatible remote control model.
- Wackelkontakt: Turn off power at the breaker, then re-check the square plug connection of the receiver within the fan housing to ensure it is secure.
Problem: Fan Operates Intermittently or Incorrectly
- Interferenz: Other electronic devices or nearby remote controls might cause interference. Try operating the fan from a different distance or checking for other active remotes.
- Überlast: Ensure the fan motor and light wattage do not exceed the receiver's maximum load ratings (1.0A for motor, 100W incandescent / 60W LED for light).
- Beschädigter Empfänger: If all other troubleshooting steps fail, the receiver may be faulty and require replacement.
Problem: Light Flickers or Does Not Turn On
- Bulb Issue: Check if the light bulb is properly screwed in or if it needs replacement.
- Wastage Überschritten: Ensure the light bulb wattage does not exceed the receiver's maximum rating (60W for LED, 100W for incandescent).
- Verdrahtung: With power off, check the light wiring connection to the receiver.
If problems persist after following these steps, consult a qualified electrician or contact Anderic customer support.
Technische Daten
| Besonderheit | Detail |
|---|---|
| Modellname | MRAC06S1M |
| Herstellermodell-Nr. | MRAC06S1M-LD-F0 |
| Marke | Anderich |
| Eingangslautstärketage | Wechselstrom 120 V, 60 Hz |
| Max Load Motor | 1.0 A |
| Max Load Light (Incandescent) | 100 W |
| Max Load Light (LED) | 60 W |
| Betriebstemperatur (Ta) | 40°C |
| Farbe | Schwarz |
| Artikelgewicht | 3.36 Unzen |
| Controllertyp | Button Control (via compatible remote) |
| Besonderheit | Plug-in-play, Must pair with TR214D remote (not included) |
| UPC | 191713654939 |
Garantie und Support
For warranty information and customer support regarding your Anderic MRAC06S1M Ceiling Fan Receiver, please contact Anderic directly or refer to their official webBewahren Sie Ihren Kaufbeleg als Kaufnachweis auf.
Anderic Official WebWebsite: www.anderic.com
Weitere Hilfestellungen finden Sie auch auf der Produktseite bei Amazon: Amazon-Produktseite
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.