Einführung
Thank you for choosing the Elitech TM-2TH Digital Thermometer Hygrometer. This device is designed for precise monitoring of temperature and humidity in various environments, including refrigerators, freezers, wine cabinets, and more. Please read this manual carefully before use to ensure proper operation and to maximize the lifespan of your device.
Produkteigenschaften

The Elitech TM-2TH offers precision monitoring with a temperature range of -10°C to 50°C and a humidity range of 10% to 95% RH. It features ultra-long battery life, flexible installation options, and a °C/°F toggle function.

This device provides high accuracy with ±1°C temperature accuracy and ±5% RH precision (within 30%~85% RH range), ensuring reliable readings for critical environments.

The TM-2TH automatically records and displays maximum and minimum temperature and humidity values, allowing users to track environmental fluctuations over time.

Designed for versatility, the thermometer hygrometer can be installed in three ways: hanging via its integrated hook, standing on a flat surface, or magnetically attached to metal surfaces.

The TM-2TH is suitable for a wide range of applications, including monitoring conditions in wine cabinets, medicine cabinets, refrigerators, camping boxes, and baby's fridges.
Technische Daten
| Modell | TM-2TH |
| Temperaturbereich | -10 °C bis 50 °C (14 °F bis 122 °F) |
| Temperaturgenauigkeit | ±1 °C (±1.8 °F) |
| Feuchtigkeitsbereich | 10 % bis 95 % relative Luftfeuchtigkeit |
| Feuchtigkeitsgenauigkeit | ±5% RH (within 30%~85% RH) |
| Akku-Typ | 1 x CR2032 (im Lieferumfang enthalten) |
| Produktreferenz | TM-2TH-2Pack |
| Verpackungsabmessungen (ca.) | 15.4 x 9.5 x 6.5 cm |
| Paketgewicht (ca.) | 90 Gramm |
| Ursprungsland | China |
Aufstellen
1. Einlegen der Batterie
- Suchen Sie die Abdeckung des Batteriefachs auf der Rückseite des Geräts.
- Öffnen Sie den Deckel, indem Sie ihn aufschieben oder vorsichtig abhebeln.
- Legen Sie eine CR2032-Batterie ein und achten Sie darauf, dass die positive Seite (+) nach oben zeigt.
- Replace the battery compartment cover securely. The device should power on automatically and display current temperature and humidity.
2. Platzierung
The TM-2TH offers multiple placement options:
- Stehen: Use the integrated kickstand to place the device on any flat surface.
- Hängend: Utilize the built-in hook to hang the device from a rack or hook.
- Magnetisch: Attach the device to any metallic surface, such as a refrigerator door, using its magnetic backing.
Choose a location that provides accurate readings for the area you wish to monitor, avoiding direct sunlight or heat sources.
Bedienungsanleitung
1. Anzeige lesen
Upon activation, the device will display the current temperature and relative humidity. The temperature is typically shown in degrees Celsius (°C) or Fahrenheit (°F), and humidity as a percentage (%).
2. Umschalten der Temperatureinheiten (°C/°F)
Locate the °C/°F button, usually on the back or side of the device. Press this button to toggle between Celsius and Fahrenheit temperature units.
3. Viewing MAX/MIN Datensätze
Das Gerät speichert automatisch die höchsten (MAX) und niedrigsten (MIN) Temperatur- und Feuchtigkeitswerte seit dem letzten Reset. view diese Aufzeichnungen:
- Drücken Sie die MAX/MIN Drücken Sie die Taste einmal, um die maximal aufgezeichneten Werte anzuzeigen.
- Drücken Sie die MAX/MIN Drücken Sie erneut, um die minimal aufgezeichneten Werte anzuzeigen.
- Press it a third time to return to the current temperature and humidity display.
4. Resetting MAX/MIN Records
To clear the recorded MAX/MIN values and start a new recording cycle:
- Während viewing the MAX or MIN records, press and hold the MAX/MIN -Taste ca. 3 Sekunden gedrückt halten.
- The display will flash, indicating that the records have been reset to the current temperature and humidity.
Wartung
1. Batteriewechsel
When the display becomes dim or the device stops functioning, it is time to replace the CR2032 battery. Follow the battery installation steps in the "Setup" section to replace the battery.
2. Reinigung
Wipe the device with a soft, dry cloth. Do not use abrasive cleaners or immerse the device in water. Ensure the sensor openings are free from dust and debris for accurate readings.
3. Speicherung
If the device will not be used for an extended period, remove the battery to prevent leakage and store it in a cool, dry place.
Fehlerbehebung
| Problem | Mögliche Ursache | Lösung |
|---|---|---|
| Keine oder nur schwache Anzeige | Die Batterie ist leer oder falsch eingesetzt. | Replace the CR2032 battery or ensure it is installed with correct polarity. |
| Ungenaue Messwerte | Sensor blocked or device placed near heat/cold source. | Ensure sensor openings are clear. Relocate the device to a more representative area. Allow time for readings to stabilize. |
| MAX/MIN-Werte werden nicht zurückgesetzt | Taste nicht lange genug gedrückt halten. | Press and hold the MAX/MIN button for at least 3 seconds until the display flashes. |
Garantie und Support
Elitech provides a standard warranty for its products. For specific warranty terms, technical support, or service inquiries, please refer to the warranty card included with your purchase or visit the official Elitech webBitte bewahren Sie Ihren Kaufbeleg für Garantieansprüche auf.
Official Elitech WebWebsite: www.elitetechlog.com