This manual provides essential information for the safe and effective use of your ResMed AirTouch F30i Clear Frame System. The AirTouch F30i Clear full face mask system features innovative AdaptiSeal™ technology within the ComfiSoft™ fabric cushion, designed to offer comfort at the seal.

Please read this manual thoroughly before using the device and retain it for future reference. This product is intended for use by patients requiring non-invasive ventilation or positive airway pressure therapy.

2. Hauptmerkmale

  • Softness and Comfort: The ComfiSoft™ cushion with AdaptiSeal™ technology combines breathable fabric and flexible silicone to gently adapt to the face, providing a soft feel without added pressure or rigid plastic.
  • Optimierte Passform: A flexible conduit frame adjusts to different facial profiles and head shapes for an accurate fit, reducing setup time. AdaptiSeal™ technology also allows flexibility during sleep movement. Cushions and frames are available in various sizes.
  • Verbesserte Flexibilität: Features a top-of-the-head tube connection with a 360-degree elbow rotation, allowing freedom of movement and various sleeping positions.
  • Benutzerfreundlichkeit: The quick-release elbow facilitates easy disconnection and reconnection from your therapy device.

3. Einrichtungsanweisungen

Before initial use, ensure you have the correct cushion and frame size for your needs. The AirTouch F30i Clear Frame System does not include headgear, which must be acquired separately.

Image showing a hand holding a ResMed AirTouch F30i cushion with 'M' for Medium size indicated, and a separate frame with 'SMALL' for frame size indicated. Text below reads 'Check the size' and 'Be sure to confirm the size of both the cushion and frame'.

Figure 3.1: Confirming Cushion and Frame Size. This image illustrates how to identify the cushion size (M for Medium) and frame size (SMALL) on the components of the AirTouch F30i system. It emphasizes the importance of verifying both components' sizes for a proper fit.

  1. Komponenten prüfen: Carefully unpackage and inspect all components of your AirTouch F30i Clear Frame System for any damage.
  2. Assemble Cushion and Frame: Attach the ComfiSoft™ cushion to the flexible frame. Ensure it is securely seated to prevent leaks.
  3. Anschlusskopfbedeckung (separat erhältlich): If you have compatible headgear, connect it to the frame according to the headgear's instructions.
  4. Attach Elbow and Tubing: Connect the quick-release elbow to the mask frame. Then, attach your CPAP tubing to the elbow.
Image showing the disassembled components of the ResMed AirTouch F30i Clear Frame System, including the cushion, flexible frame, and elbow connector, with a separate headgear shown in the background. Text reads 'AirTouch™ F30i Clear Frame System (Without Headgear)' and 'Tube-up design lets you sleep in any position'.

Figure 3.2: AirTouch F30i Clear Frame System Components. This image displays the main components of the AirTouch F30i Clear Frame System, highlighting its tube-up design and confirming that headgear is not included. It shows the cushion, frame, and elbow connector.

4. Bedienungsanleitung

Once assembled, the AirTouch F30i Clear Frame System is designed for comfortable and flexible use during sleep therapy.

  1. Donning the Mask: Hold the mask against your face and pull the headgear over your head. Adjust the headgear straps evenly until the mask feels secure and comfortable, without overtightening.
  2. Connecting to Therapy Device: Connect the CPAP tubing from your therapy device to the quick-release elbow on the mask.
  3. Starting Therapy: Turn on your therapy device. Lie down and adjust the mask position slightly if necessary to achieve a comfortable and effective seal. The flexible frame and top-of-the-head tube connection allow for various sleeping positions.
  4. Trennung: To temporarily disconnect from your therapy device, simply press the quick-release tabs on the elbow and detach the tubing. The mask can remain on your face.
Image of a person sleeping on their side, wearing the ResMed AirTouch F30i mask. The text highlights 'Flexible Frame' and states it's 'Designed to adapt to different facial profiles and head shapes for an accurate fit the first time'.

Figure 4.1: User wearing the AirTouch F30i mask while sleeping. This image demonstrates the mask's flexible frame adapting to a user's facial profile, allowing for comfortable sleep in various positions due to its design.

5. Wartung und Reinigung

Regular cleaning and maintenance are crucial for the hygiene and longevity of your AirTouch F30i Clear Frame System.

Image detailing the cleaning steps for the ResMed AirTouch F30i Clear Frame System. Steps include soaking components, hand washing the cushion without a bristled brush, hand washing other components with a soft non-metallic brush, rinsing, squeezing excess water from the cushion, shaking the QuietAir™ vent, and air drying away from direct sunlight.

Figure 5.1: Caring for your AirTouch F30i Clear Frame System. This image provides a visual guide to the recommended cleaning process for the mask components, emphasizing gentle handling of the cushion and proper drying techniques.

Tägliche Reinigung

  • Weichen Sie die Komponenten in warmem Wasser mit einem milden Flüssigwaschmittel ein.
  • Hand wash the AirTouch™ F30i cushion only, without using a bristled brush.
  • Hand wash other components with a soft, non-metallic bristled brush (e.g., a soft toothbrush).
  • Alle Komponenten gründlich unter fließendem Wasser abspülen.
  • Squeeze the cushion with a clean towel to remove excess water.
  • For the QuietAir™ vent, shake to remove any excess water.
  • Lassen Sie die Komponenten vor direkter Sonneneinstrahlung an der Luft trocknen.

Ersatzplan

We recommend replacing your frame system every three months to ensure optimal performance and hygiene.

Image showing a clear frame system for a CPAP mask with text 'Replacement tip' and 'We recommend replacing your frame system every three months'. Below are bullet points listing signs it might be time to replace: Cracks, Tears, Other visible signs of deterioration.

Figure 5.2: Replacement Tip for Frame System. This image advises users to replace the frame system every three months and lists common signs of wear and tear, such as cracks, tears, or other visible deterioration, that indicate a need for replacement.

Anzeichen dafür, dass es Zeit sein könnte, Ihr Rahmensystem zu ersetzen:

  • Risse
  • Tränen
  • Weitere sichtbare Anzeichen von Verschleiß

6. Fehlerbehebung

If you encounter issues with your AirTouch F30i Clear Frame System, consider the following common solutions:

Problem Mögliche Ursache Lösung
Luftleckage Mask not fitted correctly; cushion worn out; headgear too loose/tight. Readjust headgear for a snug but comfortable fit. Ensure cushion is properly seated on the frame. Inspect cushion for tears or wear and replace if necessary.
Discomfort/Red Marks Mask overtightened; incorrect mask size; cushion not clean. Loosen headgear straps. Verify you are using the correct cushion and frame size. Clean the cushion thoroughly.
Difficulty Breathing Vent blocked; mask components dirty. Check the QuietAir™ vent for obstructions and clean all mask components as per maintenance instructions.

If problems persist, consult your healthcare provider or contact ResMed customer support.

7. Spezifikationen

Spezifikation Detail
Technische Daten 8.66 x 11.81 x 3.15 Zoll
Artikelgewicht 3.52 Unzen
Hersteller ResMed
ASIN B0G36C2WBV
Datum der ersten Verfügbarkeit 20. November 2025

8. Garantie und Support

For warranty information, product support, or to purchase replacement parts, please refer to the official ResMed website or contact ResMed customer service directly. Keep your purchase receipt as proof of purchase.

ResMed Contact Information:

  • Offiziell WebWebsite: www.resmed.com
  • Customer Support: Refer to the contact section on the ResMed website for regional support numbers and email.

© 2026 ResMed. Alle Rechte vorbehalten. Änderungen vorbehalten.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.