diymore U-18

Diymore U-18 USB-C Tester User Manual

Multi-Function Voltage und Strommesser

1. Einleitung

The Diymore U-18 USB-C Tester is a versatile 2-in-1 device designed for monitoring USB-C power delivery, voltage, current, and other charging parameters. It features a 1.77-inch TFT color LCD screen for clear data display and supports various fast charging protocols, including PD and QC2.0/3.0. This manual provides comprehensive instructions for its safe and effective use.

Video 1: Überview of the Diymore U-18 USB-C Tester. This video demonstrates the physical appearance and basic functionality of the device, showcasing dank seines kompakten Designs und Displays.

2. Produktüberschreitungview

2.1 Hauptmerkmale

  • Hochauflösendes Display: 1.77-inch TFT screen shows real-time voltage, current, power, and charging data.
  • Multiprotokoll-Unterstützung: Compatible with PD and QC2.0/3.0 charging protocols.
  • Comprehensive Measurements: Monitore Voltage (4-25V), current (up to 6.5A), power output, and charging protocols with ±0.1V/0.01A accuracy.
  • Anpassbare Schnittstelle: Features 7 different display interfaces for various charging parameters and statistics.
  • Erweiterte Diagnose: Measures wire internal resistance using the pressure difference method to evaluate charging efficiency and cable quality.

2.2 Komponenten und Schnittstelle

Diymore U-18 USB-C Tester Components

Abbildung 1: Diagram illustrating the various ports and control buttons on the Diymore U-18 USB-C Tester. This includes the Type-C Input, Type-C Output, USB-A Input, USB-A Output, USB-HID, Micro USB Input, and the control keys (ENTER, KEY-, KEY+, PD Communication Switch, BACK Key).

The U-18 tester features multiple input/output ports and control buttons:

  • Typ-C-Eingang: Connects to the power source (e.g., charger).
  • Typ-C-Ausgang: Connects to the device being charged/tested.
  • USB-A Input (4V-24V): Connects to a USB-A power source.
  • USB-A Output (0-6.5A): Connects to a USB-A device being charged/tested.
  • USB-HID: For data communication with a computer (if supported by firmware).
  • Micro USB Eingang: For external power supply or firmware updates.
  • 1.77-Zoll-TFT-Farb-LCD-Bildschirm: Displays all measurement data.
  • (1) ENTER Key: Bestätigt die Auswahl oder ruft Menüs auf.
  • (2) KEY - Key: Navigiert nach unten oder verringert Werte.
  • (3) KEY + Key: Navigiert nach oben oder erhöht Werte. (Long press to toggle display orientation)
  • (4) PD Communication Switch: Activates/deactivates PD communication.
  • (5) BACK Key: Kehrt zum vorherigen Bildschirm oder Menü zurück.

3. Einrichtung und grundlegende Bedienung

3.1 Anschließen des Testers

  1. Identify the appropriate input port (USB-A or Type-C) on the tester based on your power source.
  2. Connect the power source (e.g., wall charger, power bank) to the tester's input port.
  3. Connect the device you wish to test (e.g., smartphone, tablet) to the tester's corresponding output port (USB-A or Type-C).
  4. The tester's screen should illuminate and begin displaying real-time data.

3.2 Reading Basic Measurements

Multiple Test Data Indicators

Abbildung 2: Example of the tester's display showing various measurement data, including voltage, current, power, energy statistics, capacity statistics, and fast charging protocol information.

Upon connection, the main display will show key parameters:

  • Bandtage(V): Die elektrische Potenzialdifferenz.
  • Strom (A): Die Flussrate der elektrischen Ladung.
  • Leistung (W): Die Geschwindigkeit, mit der elektrische Energie übertragen wird.
  • Kapazität (Ah): Accumulated charge over time.
  • Energie (Wh): Accumulated energy over time.
  • D+/D- Voltage: Datenleitungsvoltages, useful for protocol detection.
  • Protokoll: Indicates detected fast charging protocols (e.g., QC2.0, QC3.0, PD).

4. Erweiterte Funktionen

4.1 Interface Navigation and Settings

Multi-Functional Interface Settings

Abbildung 3: Various display interfaces and settings menus available on the Diymore U-18 USB-C Tester, including system settings, simple interface mode, cable measurement, and protocol detection/trigger options.

Verwenden Sie die EINGEBEN, KEY -, SCHLÜSSEL +, Und ZURÜCK keys to navigate through different display interfaces and settings menus. A long press on the SCHLÜSSEL + button can rotate the display orientation.

  • Systemeinstellungen: Adjust display brightness, standby time, language, and perform a factory reset.
  • Einfacher Schnittstellenmodus: Provides a streamlined view of essential data.
  • Ripple/Voltage/Current Curve Interface: Displays real-time graphs of voltage und Stromschwankungen.

4.2 Messung des Kabelinnenwiderstands

Wire Internal Resistance Measurement

Abbildung 4: The tester performing a wire internal resistance measurement, displaying reference voltage/current, real voltage/current, difference, and calculated cable resistance.

To measure cable internal resistance:

  1. Navigate to the 'Cable Measurement' interface using the navigation keys.
  2. Connect the power source directly to the tester's input, and then connect the cable to be tested to the tester's output.
  3. The tester will employ the voltage drop method to measure the resistance, automatically calculating and displaying the cable resistance value. A lower resistance indicates a more efficient cable.

4.3 Fast Charging Protocol Detection and Trigger

The tester can automatically detect and trigger various fast charging protocols. Navigate to the 'Protocol Detection/Trigger' interface to:

  • Automatische Erkennung: The tester will attempt to identify the fast charging protocol supported by the connected power source.
  • Manueller Auslöser: You can manually select and trigger specific protocols like PD, QC2.0, or QC3.0 to test compatibility and performance.

5. Spezifikationen

Produktspezifikationstabelle

Abbildung 5: Detailed product specifications for the Diymore U-18 USB-C Tester, including measurement ranges, resolution, and accuracy for various parameters.

IndikatorReichweiteAuflösungGenauigkeit
Monitorlautstärketage4 bis 24 V0.00001 V± (0.2 % + 2)
Strom überwachen0-6.5A0.00001 A± (0.5 % + 2)
Strom überwachen0-156 W0.00001 W± (0.5 % + 2)
D+/D- Voltage0 bis 3.3 V0.001 V± (1.0 % + 2)
Kapazität0-9999.99Ah0.00001 Ah-
Stromverbrauch0-9999.99 Wh0.00001 Wh-
Cable Internal Resistance0 bis 9999.9 Ω0.0001 Ω-
Running Time of Equipment99 Tage 23:59:591 Sekunde-
Rekordzeit1900/2/10 15:59:591 Sekunde-

Abmessungen: 3.94 x 2.56 x 0.59 Zoll (L x B x H)

Energiequelle: USB-C

Betriebstemperaturbereich: 32 °C bis 140 °C (0 °F bis 60 °F)

6. Fehlerbehebung

6.1 Display Not Lighting Up with Type-C PD

Troubleshooting Type-C PD Connection

Abbildung 6: Visual guide for troubleshooting when the tester screen does not light up with a Type-C PD connection, showing solutions like flipping the connector or using the built-in Type-C interface.

If the tester screen does not light up when connected to a Type-C PD power source:

  1. Flip the Type-C connector: Type-C connectors are reversible. Try unplugging and re-inserting the connector with the opposite orientation.
  2. Use the built-in Type-C interface: Ensure you are using the dedicated Type-C input/output ports on the tester for PD connections.

Notiz: When the PD power supply is not connected to a fast charging device, it may not be powered by default.

6.2 Ungenaue Messwerte

  • Stellen Sie sicher, dass alle Verbindungen sicher und frei von Schmutz sind.
  • Test with a different cable or power source to rule out external factors.
  • Perform a factory reset via the system settings menu if persistent issues occur.

7. Sicherheitshinweise

  • Setzen Sie das Gerät keinen extremen Temperaturen, Feuchtigkeit oder direkter Sonneneinstrahlung aus.
  • Lassen Sie das Gerät nicht fallen und setzen Sie es keinen starken Stößen aus.
  • Versuchen Sie nicht, das Gerät zu zerlegen oder zu verändern, da dies zum Erlöschen der Garantie führt und Schäden oder Verletzungen verursachen kann.
  • Außerhalb der Reichweite von Kindern aufbewahren.

8. Garantie und Support

Diymore products are designed for quality and reliability. This product comes with an 18 Monate Garantie ab Kaufdatum. Wir bieten außerdem an: 30-tägiges Rückgaberecht for any reason. For technical assistance or warranty claims, please contact Diymore customer support. Our team is available for 24-Stunden-Kundensupport to address any questions or concerns you may have.

Weitere Hilfe finden Sie unter Diymore Store on Amazon.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.