Einführung

Thank you for choosing the Antec Vortex View 360 AIO Liquid CPU Cooler. This manual provides essential information for the proper installation, operation, and maintenance of your new cooling system. Please read this manual thoroughly before installation to ensure optimal performance and longevity of your product.

Antec Vortex View 360 AIO Liquid CPU Cooler with radiator, three fans, and pump block featuring an integrated display.

Ein Überview of the Antec Vortex View 360 AIO Liquid CPU Cooler, showcasing the 360mm radiator with three 120mm fans and the pump block with its integrated 5-inch IPS display.

Sicherheitshinweise

Bitte beachten Sie die folgenden Sicherheitsvorkehrungen, um Schäden am Produkt oder Verletzungen zu vermeiden:

  • Vor der Installation oder Wartung stellen Sie bitte sicher, dass Ihr Computer vollständig vom Stromnetz getrennt ist.
  • Die Bauteile sind vorsichtig zu behandeln, um Beschädigungen zu vermeiden.
  • Do not open the pump or radiator, as this may void the warranty and cause liquid leakage.
  • Keep the product away from extreme temperatures, humidity, and direct sunlight.
  • Verwenden Sie ausschließlich das mitgelieferte Zubehör und Montagematerial.

Packungsinhalt

Überprüfen Sie, ob alle Komponenten in Ihrem Paket vorhanden sind:

  • Antec Vortex View 360 AIO Cooler (Radiator, Pump, Fans)
  • Mounting Hardware for Intel (LGA 115X/1200/1700/1851)
  • Montagehardware für AMD (AM4/AM5)
  • USB 3.0 Hub with Passthrough Cable
  • Lüfter- und RGB-Kabel
  • Bedienungsanleitung
Image showing the various components included in the Antec Vortex View 360 package and a list of compatible CPU sockets.

A visual representation of the components included in the Antec Vortex View 360 AIO cooler package, alongside a list of supported CPU sockets: Intel LGA115X/1200/1700/1851 and AMD AM4/AM5.

Installationshandbuch

1. Vorbereitung

  • Ermitteln Sie Ihren CPU-Sockeltyp (Intel LGA oder AMD AM).
  • Stellen Sie sicher, dass Ihr PC-Gehäuse ausreichend Platz für einen 360-mm-Radiator bietet.
  • Gather necessary tools (screwdriver, etc.).

2. Montage des Kühlers und der Lüfter

  1. Attach the three 120mm fans to the radiator using the provided screws. Ensure the fan airflow direction is appropriate for your case's cooling strategy.
  2. Mount the radiator assembly to the designated location in your PC case (e.g., top, front).

3. Installing the Pump Block

The pump block comes with pre-applied thermal paste. If you prefer to use your own, carefully clean off the pre-applied paste before applying a new layer.

  1. Install the appropriate mounting brackets for your CPU socket onto the pump block.
  2. Carefully place the pump block onto your CPU, aligning it with the mounting holes.
  3. Secure the pump block using the provided thumb screws or nuts, tightening them in a cross pattern until snug.
  4. For optimal thermal contact, orient the cold plate as follows: Intel CPUs at 6 o'clock, AMD CPUs at 3 o'clock.
Diagram showing optimal cold plate orientation for Intel (6 o'clock) and AMD (3 o'clock) CPUs for the Antec Vortex View 360.

Illustrations detailing the recommended cold plate orientation for Intel (6 o'clock) and AMD (3 o'clock) processors to ensure optimal thermal contact and efficient heat transfer.

The integrated 5-inch IPS display on the pump block features a 360° Rotatable Ball Joint. This allows you to freely adjust and lock the display angle after installation using the built-in twist dial, ensuring optimal viewing from any angle without needing tools.

Close-up of the Antec Vortex View 360 pump block showing the 360-degree rotatable ball joint mechanism for display adjustment.

This image illustrates the 360° rotatable ball joint on the pump block, allowing users to freely adjust and lock the display angle for optimal viewing without tools.

4. Verbindungskabel

  1. Connect the fan PWM cables to the CPU_FAN or AIO_PUMP headers on your motherboard, or to a fan hub if applicable.
  2. Connect the pump power cable to the dedicated AIO_PUMP header or a suitable fan header on your motherboard.
  3. Connect the USB cable from the pump to the provided USB 3.0 Hub with Passthrough. Then, connect the USB hub to an available USB 2.0 or 3.0 header on your motherboard. This allows the pump to communicate with the Antec iUnity software while keeping front-panel USB ports accessible.
  4. Connect the RGB cables from the fans and pump to your motherboard's ARGB header or a compatible RGB controller.
Diagram illustrating the USB 3.0 Hub with Passthrough connection from the pump to the motherboard.

This diagram explains the USB 3.0 Hub with Passthrough feature, allowing the pump to connect to the motherboard while maintaining accessibility for front-panel USB ports.

Bedienungsanleitung

IPS Display Customization

The Antec Vortex View 360 features a vivid 5-Zoll IPS-Display with 1280x720 resolution and 300 nits brightness. This display is fully customizable via the Antec iUnity software to show real-time CPU/GPU temperatures, system statistics, animated GIFs, or personalized images.

The 5-inch IPS display of the Antec Vortex View 360 AIO cooler showing its dimensions and clear visibility.

Eine detaillierte view of the 5-inch IPS display, highlighting its 1280x720 resolution, 60Hz refresh rate, and 300 nits brightness, designed for clear visibility of system stats, animations, or custom media.

Antec iUnity 2.0 Software

Download and install the Antec iUnity 2.0 software from the official Antec website. This software provides comprehensive control over your cooling system:

  • Fan and Pump Curves: Adjust fan speeds and pump performance based on temperature thresholds.
  • RGB-Beleuchtung: Customize the addressable RGB backglow system with various effects and colors.
  • Display Personalization: Upload custom images, GIFs, or select from pre-set monitoring displays for the IPS screen.
Screenshot of the Antec iUnity 2.0 software interface, showing lighting customization options.

A screenshot of the iUnity 2.0 software dashboard, demonstrating its capabilities for adjusting fan and pump curves, customizing per-zone RGB lighting on the Vortex View, and personalizing the display content.

RGB Backglow System

The pump block features an addressable RGB panel behind the display, delivering customizable ambient lighting. This system can be synchronized with other RGB components in your PC via the Antec iUnity software, allowing you to set custom lighting zones and effects.

The RGB backglow system of the Antec Vortex View 360 pump block illuminating the surrounding components.

This image demonstrates the addressable RGB panel located behind the display, providing customizable ambient lighting across the pump block and adjacent components, controllable via Antec iUnity software.

Wartung

Regular maintenance helps ensure the longevity and optimal performance of your AIO cooler:

  • Staubreinigung: Reinigen Sie die Kühlrippen und Lüfterflügel des Kühlers regelmäßig mit Druckluft, um Staubablagerungen zu vermeiden, die den Luftstrom und die Kühlleistung beeinträchtigen können.
  • Kabelmanagement: Stellen Sie sicher, dass alle Kabel fest angeschlossen sind und den Luftstrom nicht behindern.
  • Software-Updates: Keep the Antec iUnity software updated to the latest version for new features and performance improvements.
  • Dichtheitsprüfung: While rare, periodically check for any signs of liquid leakage around the pump block and tubing. If a leak is detected, immediately power off your system and contact Antec support.
Diagram showing the internal components of the Antec Vortex View 360 pump, emphasizing its low-resonance design.

Eine interne view of the Vortex View pump, illustrating its engineering for low-resonance operation and sub-14 dBA acoustics at 2800 RPM, ensuring quiet performance.

Fehlerbehebung

Sollten Probleme auftreten, beachten Sie bitte die folgenden gängigen Schritte zur Fehlerbehebung:

  • Kein Strom/Lüfter drehen sich nicht:
    • Überprüfen Sie alle Stromanschlüsse an Pumpe und Lüftern.
    • Ensure the pump is connected to the correct motherboard header (AIO_PUMP or CPU_FAN).
    • Verify fan cables are properly connected to the motherboard or fan hub.
  • Hohe CPU-Temperaturen:
    • Confirm the pump block is securely mounted to the CPU and making good contact.
    • Check if thermal paste is properly applied.
    • Stellen Sie sicher, dass die Lüfter richtig laufen und ausgerichtet sind, um einen optimalen Luftstrom zu gewährleisten.
    • Entfernen Sie jeglichen Staub von den Kühlrippen des Kühlers.
    • Verify pump and fan speeds in Antec iUnity software.
  • Display Not Working/Showing Incorrect Info:
    • Ensure the USB cable from the pump to the USB hub, and from the hub to the motherboard, is securely connected.
    • Restart the Antec iUnity software.
    • Check for software updates for Antec iUnity.
  • RGB Not Functioning:
    • Verify all RGB cables are correctly connected to the motherboard's ARGB header or controller.
    • Check RGB settings in Antec iUnity software or your motherboard's RGB software.

Technische Daten

Besonderheit Detail
Technische Daten 15.51 Zoll L x 4.72 Zoll B x 1.06 Zoll H
Marke Antec
Typ des Stromanschlusses 4-polig
Bandtage 12 Volt
Wastage 400 Watt (TDP-Unterstützung)
Kühlmethode Wasser
Kompatible Geräte Desktop
Geräuschpegel 28.6 Decibels (Fans), Sub-14 dBA (Pump at 2800 RPM)
Maximale Drehzahl 2000 U/min (Lüfter)
Luftstromkapazität 59.23 Kubikfuß pro Minute
Artikelgewicht 4 Pfund
Modell Wirbel View 360
CPU-Sockel-Kompatibilität Intel LGA 115X/1200/1700/1851 & AMD AM4/AM5
IPS-Bildschirm 5" IPS, 1280x720 resolution, 300 nits brightness

Garantie

The Antec Vortex View 360 AIO Liquid CPU Cooler comes with a 6 Jahr Garantie from the date of purchase. This warranty covers defects in materials and workmanship under normal use. Please retain your proof of purchase for warranty claims. For detailed warranty terms and conditions, please refer to the official Antec webWebsite.

Unterstützung

For technical assistance, troubleshooting beyond this manual, or warranty inquiries, please visit the official Antec support website or contact their customer service. You can typically find contact information on the Antec webauf der Website oder auf der Produktverpackung.

Antec Official WebWebsite: www.antec.com

© 2026 Antec Inc. Alle Rechte vorbehalten.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.