1. Einleitung
The PEAKMETER PM6508 is a professional digital temperature and humidity meter designed for accurate measurement of ambient temperature, relative humidity, wet bulb temperature, and dew point temperature. This handheld device is suitable for various industrial applications, including environmental monitoring in farms and warehouses. It features a clear HD display, data logging capabilities, and a durable, shatter-resistant design.

Figure 1: PEAKMETER PM6508 Digital Temperature & Humidity Meter
2. Produktmerkmale
- Measures Ambient Temperature, Relative Humidity, Wet Bulb Temperature, and Dew Point Temperature.
- High precision measurements for reliable data.
- Large, clear HD digital display for easy reading.
- Data Hold function to freeze current readings.
- MAX/MIN function to record extreme values.
- Data Storage for up to 100 groups of readings.
- Umschaltbare Temperatureinheiten (°C/°F).
- Hintergrundbeleuchtung für bessere Sichtbarkeit bei schlechten Lichtverhältnissen.
- Automatic Power-Off feature to conserve battery life.
- Durable, shatter-resistant cover and non-slip design for robust use.
- Equipped with a high-quality Switzerland Sensirion SHT11 sensor.
- Powered by a TI MSP430F135 Microprocessor.
- CE-zertifiziert für Sicherheit und Qualität.
3. Produktspezifikationen

Abbildung 2: Detaillierte Produktparameter
| Technische Daten | Reichweite | Auflösung | Genauigkeit |
|---|---|---|---|
| Umgebungstemperatur | -20°C bis 0°C (-4°F bis 32°F) 0°C – 45°C (32°F – 113°F) 45°C – 60°C (113°F – 140°F) | 0.1 °C/°F 0.1 °C/°F 0.1 °C/°F | ±1.5 °C ±0.5 °C ±1.5 °C |
| Relative Luftfeuchtigkeit | 0 % bis 20 % 20 % bis 80 % 80 % bis 100 % | 0.1 % 0.1 % 0.1 % | ±4.0 % ±3.0 % ±4.0 % |
| Feuchtkugeltemperatur | -20°C bis 0°C (-4°F bis 32°F) 0°C – 45°C (32°F – 113°F) 45°C – 60°C (113°F – 140°F) | 0.1 °C/°F 0.1 °C/°F 0.1 °C/°F | ±1.5 °C ±0.5 °C ±1.5 °C |
| Taupunkttemperatur | -50°C bis 0°C (-58°F bis 32°F) 0°C – 45°C (32°F – 113°F) 45°C – 60°C (113°F – 140°F) | 0.1 °C/°F 0.1 °C/°F 0.1 °C/°F | ±1.5 °C ±0.5 °C ±1.5 °C |
Allgemeine Spezifikationen:
- Datenaufnahme: Ja
- Data Logging and Recall: 100 Gruppen
- °C/°F-Auswahl: Ja
- Hintergrundbeleuchtung: Ja
- Max Min: Ja
- Stromversorgung: 4 x 1.5V AAA-Batterie (nicht im Lieferumfang enthalten)
- Gewicht: Ca. 190g
- Größe: 184 mm × 60 mm × 29 mm
- Sicherheitsbewertung: CE CAT.III 300V RoHS
4. Komponenten und Bedienelemente

Figure 3: PM6508 Digital Temperature & Humidity Meter Controls
- Temperatur- und Feuchtigkeitssensor: Located at the top, protected by a shatter-resistant cover.
- HD-Anzeige: Shows temperature, humidity, and other readings.
- Power On/Power Off Button: Dient zum Ein- und Ausschalten des Geräts.
- MAX/MIN-Taste: Schaltet zwischen Maximal-, Minimal- und aktuellen Messwerten um.
- Mode Switch (H Button): Activates Data Hold function.
- DP WB Button: Switches between Dew Point and Wet Bulb temperature display.
- MEM-Taste: Initiates data storage.
- LESEN-Schaltfläche: Ruft gespeicherte Daten ab.
- Taste für Hintergrundbeleuchtung: Schaltet die Display-Hintergrundbeleuchtung ein/aus.
- °C/°F-Taste: Schaltet zwischen Celsius und Fahrenheit um.
- Battery Jar: Compartment for batteries, located at the back.
- Rutschfestes Design: Ergonomisches Design für sichere Handhabung.

Figure 4: High-precision Switzerland Sensirion SHT11 Sensor
5. Einrichtung und Installation
5.1 Einlegen der Batterie
The PM6508 requires four (4) 1.5V AAA batteries (not included). To install the batteries:
- Suchen Sie das Batteriefach auf der Rückseite des Geräts.
- Öffnen Sie die Batterieabdeckung.
- Insert four AAA batteries, ensuring correct polarity (+ and -).
- Schließen Sie die Batterieabdeckung fest.
Note: Batteries are not included due to air mail regulations.

Figure 5: Battery Compartment and Installation
6. Bedienungsanleitung
6.1 Ein-/Ausschalten
- Drücken Sie die Ein-/Ausschalten button (green circle) to turn the device on.
- Halten Sie die Ein-/Ausschalten Taste, um das Gerät auszuschalten.
6.2 Measuring Temperature and Humidity
Upon powering on, the device will automatically display the current ambient temperature and relative humidity. Ensure the sensor at the top is exposed to the environment you wish to measure.
6.3 Schalttemperatureinheiten (°C/°F)
- Drücken Sie die ° C / ° F Taste zum Umschalten zwischen Celsius und Fahrenheit-Temperatureinheiten.
6.4 Datenhaltefunktion
- Drücken Sie die H button to freeze the current readings on the display. The "HOLD" indicator will appear.
- Drücken Sie die H button again to release the data hold and resume live readings.
6.5 MAX/MIN Messung
- Drücken Sie die MAX/MIN Taste zum Durchschalten der Maximal-, Minimal- und aktuellen Messwerte.
- The display will show "MAX" or "MIN" to indicate the mode.
- Drücken Sie die Taste wiederholt, um view the maximum, minimum, and then return to current readings.
6.6 Dew Point and Wet Bulb Temperature
- Drücken Sie die DP WB button to switch the display to show Dew Point Temperature or Wet Bulb Temperature.
- The corresponding indicator ("DEW POINT" or "WET BULB") will appear on the screen.
6.7 Data Storage and Retrieval (MEM/READ)
The device can store up to 100 groups of data.
- To store data: Press the MEM button. The current readings will be saved.
- To retrieve stored data: Press the LESEN Klicken Sie auf die Schaltfläche MINIMAL MAXIMAL buttons to navigate through the stored data groups.
6.8 Hintergrundbeleuchtung
- Drücken Sie die Hintergrundbeleuchtung button (sun icon) to turn the display backlight on or off.
6.9 Automatische Abschaltung
The device features an automatic power-off function to save battery. If no button is pressed for a certain period, the meter will automatically shut down. This feature can usually be disabled or adjusted in advanced settings, though specific instructions are not provided here.
7. Wartung
- Reinigung: Reinigen Sie das Gerät mit einem weichen, trockenen Tuch. Verwenden Sie keine Scheuermittel oder Lösungsmittel.
- Lagerung: Bei längerer Nichtbenutzung sollten die Batterien entfernt werden, um ein Auslaufen zu verhindern. Das Gerät sollte an einem kühlen, trockenen Ort, vor direkter Sonneneinstrahlung und extremen Temperaturen geschützt aufbewahrt werden.
- Sensorpflege: Keep the temperature and humidity sensor clean and free from dust or debris to ensure accurate readings. Avoid touching the sensor directly.
- Batteriewechsel: Tauschen Sie die Batterien umgehend aus, sobald die Anzeige für niedrigen Batteriestand erscheint.
8. Fehlerbehebung
| Problem | Mögliche Ursache | Lösung |
|---|---|---|
| Gerät lässt sich nicht einschalten | Defekte oder falsch eingesetzte Batterien. | Batteriepolung prüfen. Durch neue AAA-Batterien ersetzen. |
| Ungenaue Messwerte | Sensor obstructed or dirty; device not acclimatized to environment; low battery. | Clean the sensor. Allow device to stabilize in the measurement environment. Replace batteries. |
| Das Display ist dunkel oder flackert | Schwache Batterie. | Batterien ersetzen. |
| Cannot store or recall data | Memory full; incorrect button sequence. | Ensure memory is not full (if applicable, manual does not specify how to clear). Refer to operating instructions for correct button usage. |
9. Benutzertipps
Based on common user experiences with similar devices:
- For best accuracy, allow the meter to stabilize in the measurement environment for at least 15-30 minutes before taking readings.
- Avoid exposing the sensor directly to moisture or extreme temperature changes to prevent damage.
- When measuring in different locations, ensure the sensor is clean and free from residual moisture from previous measurements.
10. Garantie und Support
PEAKMETER provides a warranty for its products:
- Most items come with a 1-year warranty from the date of purchase.
- Accessories typically come with a 3-month warranty.
For defective or faulty products, please take photos or videos and contact PEAKMETER Official Store customer support for assistance. Please retain your proof of purchase for warranty claims.