Hanmatek DOS1102

Hanmatek DOS1102 Digitaloszilloskop Benutzerhandbuch

Model: DOS1102 | Brand: Hanmatek

1. Einleitung

The Hanmatek DOS1102 is a high-performance digital storage oscilloscope designed for various electronic measurement tasks. Featuring a 110MHz bandwidth, 1GSa/s real-time sampling rate, and a 7-inch TFT LCD, it provides reliable and accurate waveform analysis. This manual provides essential information for setting up, operating, maintaining, and troubleshooting your DOS1102 oscilloscope.

2. Einrichtung

2.1. Auspacken und Inspektion

Carefully unpack the oscilloscope and check for any signs of damage. Verify that all standard accessories are included:

  • Hanmatek DOS1102 Digital Oscilloscope
  • Zwei Oszilloskop-Tastköpfe
  • Power Cords (specific to region)
  • Adjustment Tool (screwdriver)
  • Kurzanleitung / Benutzerhandbuch
  • Software-CD
Hanmatek DOS1102 Oszilloskop und mitgeliefertes Zubehör
Figure 2.1: Hanmatek DOS1102 Oscilloscope and standard accessories, including probes, power cords, adjustment tool, and documentation.

2.2. Körperliche Übergriffeview

Familiarize yourself with the front panel controls and connectors:

Vorderseite view of Hanmatek DOS1102 Oscilloscope
Figure 2.2: Front panel of the DOS1102, showing the 7-inch display, control knobs for Multipurpose, Position, Horizontal, Vertical, and Trigger, along with CH1 and CH2 input connectors.
  • Anzeige: 7-inch TFT (True Color) LCD screen with 65535 colors and 800 x 480 pixels resolution.
  • Eingangskanäle (CH1, CH2): BNC connectors for probe connection.
  • Steuerknöpfe: Dedicated knobs for Multipurpose, Position, Horizontal, Vertical, and Trigger adjustments.
  • Funktionstasten: Buttons for Utility, Measure, Acquire, Cursor, Display, Storage, etc.
  • USB-Host-Schnittstelle: Located on the front panel for data storage.
Close-up of USB port on Hanmatek DOS1102 Oscilloscope
Figure 2.3: The USB Device & Host interface, allowing for data storage with a record length of each acquired waveform not less than 10K sampling-Punkte.

2.3. Stromversorgung anschließen

Connect the provided power cord to the AC input on the rear panel of the oscilloscope and then to a suitable power outlet.

2.4. Anschluss der Sonden

Connect the oscilloscope probes to the CH1 and CH2 BNC input connectors on the front panel. Ensure a secure connection. The probes are used to connect the oscilloscope to the circuit under test.

Connecting oscilloscope probes to a circuit board
Abbildung 2.4: Bspample of connecting oscilloscope probes to a circuit for measurement.

3. Bedienungsanleitung

3.1. Ein-/Ausschalten

Drücken Sie den Netzschalter an der Vorderseite, um das Oszilloskop ein- oder auszuschalten.

3.2. Basic Waveform Display

After powering on, connect a signal to CH1 or CH2. Use the Vertical (Position and Scale) and Horizontal (Position and Scale) knobs to adjust the waveform's position and size on the screen. The oscilloscope features a 110MHz bandwidth and 1GSa/s real-time sampling rate for accurate signal capture.

Oscilloscope display showing a waveform
Figure 3.1: The 7-inch TFT LCD displaying a waveform, with 800x480 pixel resolution for clear visualization.

3.3. Auslösung

The Trigger section allows you to stabilize repetitive waveforms. Adjust the Trigger Level knob to set the voltage threshold at which the oscilloscope starts acquiring data. Use the Trigger Menu button to access advanced trigger settings.

3.4. Messungen

Press the 'Measure' button to access automatic measurement functions. The oscilloscope can display various parameters such as frequency, peak-to-peak voltage, RMS-Volumentage und mehr.

3.5. Datenspeicherung

The USB Host interface on the front panel allows you to save waveform data, screenshots, and settings to a USB flash drive. The storage depth for acquired waveforms is not less than 10K sampling-Punkte.

Oscilloscope connected to a circuit, highlighting key specifications
Figure 3.2: The DOS1102 in use, emphasizing its 110MHz bandwidth, 1GSa/s real-time sampling rate, and dual-channel capability.

4. Wartung

4.1. Reinigung

Verwenden Sie zum Reinigen des Oszilloskops ein weiches, trockenes Tuch. Bei hartnäckigem Schmutz wischen Sie vorsichtig mit einem Tuch darüber.ampened with water or a mild cleaning solution can be used. Avoid using abrasive cleaners or solvents that could damage the casing oder Bildschirm. Stellen Sie sicher, dass das Gerät ausgeschaltet und vom Stromnetz getrennt ist, bevor Sie es reinigen.

4.2. Speicherung

Store the oscilloscope in a clean, dry environment away from direct sunlight, extreme temperatures, and high humidity. When not in use for extended periods, disconnect all probes and power cables.

5. Fehlerbehebung

  • Kein Strom: Ensure the power cord is securely connected to both the oscilloscope and the power outlet. Check the power button.
  • Keine Wellenformanzeige: Verify that the input signal is connected correctly to CH1 or CH2. Adjust the Vertical Scale (V/div) and Horizontal Scale (s/div) knobs to bring the waveform into view. Check the trigger settings.
  • Instabile Wellenform: Adjust the Trigger Level and Trigger Mode settings to stabilize the waveform. Ensure the trigger source is correctly selected.
  • Falsche Messungen: Calibrate probes if necessary. Ensure the input coupling (AC/DC) is appropriate for the signal being measured.
  • Gerätestörung: If the oscilloscope does not function correctly upon receipt, contact customer support for immediate assistance. The manufacturer offers replacement for new items at once for such issues.

6. Spezifikationen

Besonderheit Spezifikation
Typ Oszilloskop
Modellnummer DOS1102
Zustand 100% nagelneu
Bandbreite 110 MHz
Echtzeit-Sampling-Rate 1GSa/s
Kanäle 2 Kanäle
Maximale Wellenform-Erfassungsrate 50,000 WFM/s
Zeitbasisbereich (s/div) 2ns/div - 1000s/div, step by 1-2-5
Bildschirmauflösung 800*480 Pixel
Anzeigetyp 7-inch TFT (True Color) LCD, 65535 colors
Größe (L*B*H) 301 mm * 152 mm * 70 mm
Energieaufnahme Nicht höher als 18 W
USB-Schnittstelle USB Device & Host interface (for data storage)
Dimensions of the Hanmatek DOS1102 Oscilloscope
Figure 6.1: Physical dimensions of the ultra-portable DOS1102 oscilloscope (301x152x70mm).

7. Garantie und Support

7.1. Garantieinformationen

The Hanmatek DOS1102 oscilloscope typically comes with a warranty period. For initial defects, new items may be replaced for free within 1-3 months. For other issues, free repair services are generally available for 1-2 years, depending on the specific product and terms.

7.2. Technischer Support

For technical assistance, troubleshooting beyond this manual, or warranty claims, please contact the seller or manufacturer directly. Provide your product model (DOS1102) and a detailed description of the issue.

8. Benutzertipps

  • Sondenkalibrierung: Regularly calibrate your oscilloscope probes for accurate measurements. Most oscilloscopes have a dedicated output for probe compensation.
  • USB-Datenübertragung: Utilize the USB host interface to save important waveform data or screenshots for later analysis or documentation.
  • Anwendungsvielfalt: This oscilloscope is suitable for a wide range of applications, including PCB design, testing, and general electronic circuit analysis.

HANMATEK DOS1102 Digitaloszilloskop: Umfassende Funktionen & Anwendungsdemonstration

HANMATEK DOS1102 Digitaloszilloskop: Umfassende Funktionen & Anwendungsdemonstration

0:59 • 720×720 • feature_demo

Zugehörige Dokumente - DOS1102

Vorview HANMATEK DOS1102 Digitales Speicheroszilloskop – Kurzanleitung
Starten Sie schnell mit dem digitalen Speicheroszilloskop HANMATEK DOS1102. Diese Kurzanleitung enthält wichtige Sicherheitshinweise, Beschreibungen der Vorder- und Rückseite, der Benutzeroberfläche, grundlegende Bedienungshinweise und die PC-Kommunikation.
Vorview Hanmatek DOS1102 Digital-Speicheroszilloskop – Kurzanleitung
Eine Kurzanleitung zum digitalen Speicheroszilloskop Hanmatek DOS1102 mit Sicherheitsvorkehrungen, Beschreibungen der Vorder- und Rückseite, Steuerbereichsfunktionen, Benutzeroberfläche und grundlegenden Vorgängen wie Sondenkompensation und automatischen Messungen.
Vorview Technische Daten zum tragbaren Oszilloskop Hanmatek DOS1102
Dieses Dokument enthält detaillierte technische Details zum professionellen tragbaren Oszilloskop Hanmatek DOS1102, das bei einer Frequenz von 1 GS/s für die Relevanz in c erforderlich istampWir beziehen uns auf erneuerbare Energien, Maschinen und elektrische Anlagen und beziehen uns auf den akademischen Kontext der UANL.
Vorview Hanmatek HO11 Handheld-Oszilloskop Benutzerhandbuch
Ausführliches Benutzerhandbuch für das Hanmatek HO11-Handoszilloskop mit detaillierten Informationen zu Funktionen, Bedienung und technischen Daten. Erfahren Sie, wie Sie das Gerät für verschiedene elektronische Messszenarien verwenden.
Vorview Benutzerhandbuch für Handheld-Oszilloskope der HANMATEK HO-Serie mit Einzelkanal
Umfassendes Benutzerhandbuch für das Handheld-Oszilloskop der HANMATEK HO-Einzelkanalserie mit Sicherheitsinformationen, Bedienung, technischen Daten und Fehlerbehebung.
Vorview HANMATEK DOS1104 Digitalspeicheroszilloskop Benutzerhandbuch und Spezifikationen
Ausführliches Benutzerhandbuch für das digitale Speicheroszilloskop HANMATEK DOS1104 mit Sicherheitsvorkehrungen, Kurzanleitung, Betriebsverfahren, Schnittstellenerklärung, PC-Kommunikation und umfassenden technischen Daten.