OWON DGE1030/DGE1060

OWON DGE1030/DGE1060 Arbitrary Waveform Generator User Manual

Models: DGE1030 (30MHz), DGE1060 (60MHz)

1. Einleitung

The OWON DGE1030 and DGE1060 are high-performance single-channel arbitrary waveform generators designed for a wide range of applications in electronics testing, education, and research. These devices offer precise waveform generation with a 3.6-inch TFT LCD for intuitive operation and comprehensive functionality.

Zu den Hauptmerkmalen gehören:

2. Packungsinhalt

Bitte überprüfen Sie nach Erhalt den Inhalt des Pakets, um sicherzustellen, dass alle Artikel vorhanden und unbeschädigt sind:

OWON DGE1060 package contents

Abbildung 2.1: Mitgeliefertes Zubehör und Hauptgerät.

3. Einrichtung

3.1 Stromanschluss

  1. Connect the provided Power Adapter to the DC 5V power socket on the rear panel of the waveform generator.
  2. Plug the power adapter into a suitable power outlet (100V-240V, 50/60Hz).
  3. Press the ON/OFF button on the front panel to power on the device.
Rear panel of OWON DGE1060 showing power socket and USB port

Figure 3.1: Rear panel with Power Socket and USB Device interface.

3.2 Ausgangsverbindung

Connect the BNC to Alligator Clip cable to the 'Out1' BNC connector on the front panel. Connect the alligator clips to your test circuit or device under test.

Front panel of OWON DGE1060 showing controls and output

Figure 3.2: Front panel layout with 'Out1' channel output control area.

3.3-Zoll-PC-Anschluss (optional)

To use PC remote control via SCPI commands or LabVIEW, connect the waveform generator to your computer using the provided USB Cable. The USB Device interface is located on the rear panel.

OWON DGE1000 connected to a laptop for PC remote control

Figure 3.3: Device connected to a PC for remote control.

4. Bedienungsanleitung

4.1 Benutzeroberfläche vorbeiview

The DGE1000 series features a 3.6-inch TFT color LCD display. All channel output waveform status and menu settings are fully displayed on the screen. Convenient shortcut keys improve man-machine interaction and working efficiency.

OWON DGE1000 series front panel with labeled areas

Figure 4.1: Front panel layout: 3.6-inch TFT LCD, function setting area, ON/OFF button, channel output control area, waveform switching area.

4.2 Grundlegende Wellenformerzeugung

The device supports 5 basic waveforms: Sine, Square, Pulse, Ramp, and Noise. To select a basic waveform:

  1. Press one of the dedicated waveform buttons in the waveform switching area (e.g., Sine, Square, Ramp, Puls).
  2. Use the rotary knob and navigation buttons to adjust parameters such as Frequency, Amplitude, Offset, and Phase.
OWON DGE1000 series LCD showing Sine wave settings

Figure 4.2: LCD display showing Sine wave settings with high frequency stable output.

4.3 Erzeugung beliebiger Wellenformen

The DGE1000 series includes 160 built-in arbitrary waveforms. You can also store up to 16 non-volatile digital arbitrary waveforms.

  1. Press the 'Arb' button.
  2. Navigate through the list of built-in waveforms or select a stored user waveform.
  3. Passen Sie die Parameter nach Bedarf an.
OWON DGE1000 series LCD showing arbitrary waveform selection and modulation settings

Figure 4.3: Arbitrary waveform selection menu and modulation mode options.

4.4 Modulationsfunktionen

The device supports various modulation types:

To access modulation functions, press the 'Mode' button and select the desired modulation type from the menu. Use the rotary knob and soft keys to configure modulation parameters.

OWON DGE1060 display showing Sweep function settings

Figure 4.4: LCD display showing Sweep function settings.

OWON DGE1000 series LCD showing Burst function settings and file Management

Figure 4.5: LCD display showing Burst function settings and arbitrary waveform file Management.

5. Wartung

5.1 Allgemeine Pflege

5.2 Reinigung

To clean the exterior of the device, use a soft, damp Tuch. Verwenden Sie keine Scheuermittel oder Lösungsmittel, da diese das Material beschädigen können.asing oder Display. Stellen Sie vor der Reinigung sicher, dass das Gerät ausgeschaltet und von der Stromversorgung getrennt ist.

6. Fehlerbehebung

If you encounter issues with your OWON DGE1030/DGE1060, please refer to the following common troubleshooting steps:

Sollte das Problem nach Durchführung dieser Schritte weiterhin bestehen, wenden Sie sich bitte an den Kundendienst, um weitere Unterstützung zu erhalten.

7. Spezifikationen

The following table details the technical specifications for the OWON DGE1030 and DGE1060 models:

OWON DGE1030 DGE1060 Product Specifications Table

Figure 7.1: Detailed Product Specifications for DGE1030 and DGE1060.

Allgemeine Spezifikationen:

OWON DGE1000 series Burst function and Input/Output specifications

Figure 7.2: Burst function parameters and Input/Output specifications.

8. Garantie und Support

This product comes with a 12-month warranty from the date of purchase. For any technical assistance, warranty claims, or support inquiries, please contact your vendor or OWON customer service directly. Ensure you retain your proof of purchase for warranty validation.

9. Benutzertipps

Aus den bereitgestellten Informationen waren keine spezifischen Benutzertipps verfügbar.views or Q&A. For optimal performance, always refer to the detailed operating instructions and ensure proper connections are made before powering on the device.