SINOTIMER TM630A

SINOTIMER TM630A 12V DC Programmable Digital Timer Switch

Bedienungsanleitung

Einführung

The SINOTIMER TM630A is a compact, programmable digital timer switch designed to automatically control various electrical equipment by switching them on and off at preset times. This device is suitable for a wide range of applications, including controlling streetlights, neon signs, lamps, water heaters, air conditioners, billboards, electric cookers, boosters, sprayers, bottlers, preheaters, agriculture facilities, and broadcasting equipment. It features a built-in battery to retain programmed settings during power failures, ensuring reliable operation. The TM630A is built with a high-accuracy CMOS chip, offers strong anti-jamming capabilities, and is simple to set up and operate. It conforms to IEC 60367 standards and is CE certified.

Technische Daten

BesonderheitSpezifikation
ModellTM630A (also TM630A-4)
TypMini Digital Timer Switch
MarkennameSINOTIMER
VerwendenZeitschaltuhr
Stromversorgung12 V DC / AC
Ausgabe12V Voltage Ausgabe
Energieaufnahme3.5 VA (MAX) / 4.5 VA (MAX)
AnzeigeLCD
Schaltkontakt1 changeover switch (1NO)
Kapazität30A 250V AC (5000 Watt / 30 Amps)
Studiengänge16 Ein-/Ausschaltvorgänge pro Tag oder Woche
Programmierkombinationen15 Gruppen
Mini-Intervall1 Minute
Timerbereich1 Minute bis 168 Stunden
Temperaturbereich-20°C bis +50°C
Hysterese2 Sekunden/Tag (bei 25 °C)
Mittlerer Fehler1 sec/24h (at 25°C)
Auto Time Error Correction+/- 30 sec, weekly
InstallationDIN RAIL or Screw mounted
Maße98 x 55 x 40 mm
Gewicht0.15 kg
Inside Battery1.2V (rechargeable, for memory backup)
Black-out Memory Retention60 Tage
ZertifikateCE, RoHS, EMV, Niederspannungsdefizit

Aufstellen

1. Installation

The TM630A timer switch can be installed either on a DIN rail or screw-mounted. Ensure the installation location is dry, well-ventilated, and within the specified temperature range (-20°C to +50°C).

2. Schaltplan

Refer to the following wiring diagram for proper connection. Ensure all connections are secure and comply with local electrical codes. This diagram shows the connections for the 12V DC/AC input and the load output.

Wiring diagram for SINOTIMER TM630A timer switch, showing power input and load output connections.
Figure 1: TM630A Wiring Diagram. Connect the 12V DC/AC power supply to the input terminals (L, N) and the load to the output terminals.

The timer has two input terminals for power (typically marked L and N for AC, or + and - for DC) and two output terminals for the load.

3. Erstes Einschalten

Upon initial power-up or after extended storage, the internal 1.2V rechargeable battery may be low. Connect the timer to its power supply (12V DC/AC) for a few hours to allow the internal battery to charge. This battery maintains the programmed settings during power outages.

Bedienungsanleitung

1. Tastenfunktionen

Machen Sie sich mit den Tasten auf der Vorderseite vertraut:

Front view of the SINOTIMER TM630A timer switch, highlighting the buttons and LCD display.
Figure 2: TM630A Front Panel with Buttons.
  • C/R (Abbrechen/Zurückrufen): Clears current settings or recalls saved programs.
  • D+ (Tag): Passt den Wochentag an.
  • H+ (Stunde): Stellt die Stunde ein.
  • M+ (Minute): Passt die Minute an.
  • P (Program/Timer): Wechselt in den Programmiermodus.
  • UHR: Used in combination with D+, H+, M+ to set the current time and day.
  • HANDBUCH: Schaltet den Ausgang manuell EIN/AUS oder stellt ihn auf AUTO-Modus ein.

2. Setting the Present Time and Day

To set the current time and day of the week:

  1. Halten Sie die UHR Taste.
  2. Halten Sie UHRdrücken STUNDE um die aktuelle Stunde einzustellen.
  3. Halten Sie UHRdrücken MINUTE um die aktuelle Minute einzustellen.
  4. Halten Sie UHRdrücken TAG um den aktuellen Wochentag einzustellen.

3. Ein-/Ausschaltzeiten programmieren

The timer supports up to 16 ON/OFF programs per day or week. Follow these steps to set your desired schedules:

Programming instructions table for the timer switch, showing steps for setting time and ON/OFF programs.
Figure 3: Programming Method Table (English section).
  1. Drücken Sie die TIMER (P) button once to enter the 1st ON time setting. The display will show "1 ON".
  2. Drücken STUNDE, MINUTE, Und TAG buttons to set the desired time and day(s) for the 1st ON event.
    • TAG button allows selecting various combinations of days (e.g., MO, TU, WE, TH, FR, SA, SU; MO, TU, WE, TH, FR; SA, SU; MO, WE, FR; TU, TH, SA; MO, TU, WE; TH, FR, SA; MO, WE, FR, SA; MO, TU, WE, TH, FR, SA, SU).
  3. Drücken Sie die TIMER (P) button again. The display will show "1 OFF".
  4. Drücken STUNDE, MINUTE, Und TAG buttons to set the desired time and day(s) for the 1st OFF event.
  5. Wiederholen Sie die Schritte 1-4 für weitere EIN/AUS-Programme (bis zu 16 Paare).
  6. Um den Programmiermodus zu verlassen, drücken Sie die UHR Taste.

4. Manuelle Übersteuerung

Der HANDBUCH Mit dieser Schaltfläche können Sie die programmierten Einstellungen vorübergehend oder dauerhaft überschreiben:

  • Drücken HANDBUCH repeatedly to cycle through modes: ON (always on), OFF (always off), and AUTO (follows programmed schedule).
  • In AUTO mode, the timer will execute the programmed ON/OFF events.

Wartung

1. Interne Batterie

The TM630A includes a 1.2V rechargeable internal battery. This battery automatically recharges when the timer is connected to its power supply. It is designed to retain your programmed settings for up to 60 days during power outages. If the timer has been stored for a long period without power, allow it to charge for several hours before programming to ensure full memory retention.

2. Reinigung

To clean the timer, gently wipe the exterior with a soft, dry cloth. Do not use abrasive cleaners, solvents, or immerse the device in water.

Fehlerbehebung

  • Anzeige ist leer: Check if the timer is receiving power (12V DC/AC). If it has been without power for an extended period, the internal battery may be fully discharged. Connect to power and allow it to charge.
  • Programs are not executing:
    • Stellen Sie sicher, dass der Timer eingeschaltet ist. AUTO mode (check the display for "AUTO"). Press the HANDBUCH button to cycle to AUTO mode if necessary.
    • Überprüfen Sie, ob die aktuelle Uhrzeit und der aktuelle Tag korrekt eingestellt sind.
    • Check that the ON/OFF programs are correctly entered and enabled.
  • Zeitdrift: The timer has an auto time error correction of +/- 30 seconds weekly. Significant deviations may indicate an issue with the power supply or internal components.
  • Loss of programs after power outage: While the internal battery provides memory retention for up to 60 days, prolonged power outages or a depleted internal battery can lead to program loss. Ensure the internal battery is adequately charged.

Benutzertipps

  • For critical applications, consider testing your programmed schedules after initial setup to ensure they function as expected.
  • Nutzen Sie den Vorteiltage of the 15 programming group combinations to create complex weekly schedules for different days or sets of days.
  • The manual override function is useful for temporary changes without altering your saved programs.
  • Given its wide application range, this timer is highly versatile. Consider using it for automating garden irrigation, aquarium lighting, or even charging cycles for low-voltage-Geräte.

Garantie und Support

The SINOTIMER TM630A timer switch is certified with CE, RoHS, EMC, and LVD standards, indicating compliance with relevant health, safety, and environmental protection directives.

For warranty information, technical support, or service inquiries, please contact your original point of purchase or the manufacturer directly. The product package includes a manual in Russian, Portuguese, and English languages for detailed guidance.