1. Einleitung
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Pinyue LRS32-6G 130 Hot Water Circulation Pump. This high-pressure, silent household pump is designed for various hot water circulation applications, including floor heating, radiator systems, water heaters, water tanks, apartment pressurization, and solar heating systems.
Key features of this pump include low noise operation, high traffic volume capability, an all-copper motor, high-temperature resistance, three-speed adjustment, and built-in safety protection.

2. Sicherheitshinweise
Please read and understand all safety instructions before installing or operating the pump. Failure to follow these instructions may result in electric shock, fire, serious injury, or property damage.
- Vor jeglichen Installations-, Wartungs- oder Reparaturarbeiten muss die Stromzufuhr unterbrochen werden.
- Ensure the pump is installed by a qualified professional in accordance with local electrical and plumbing codes.
- Do not operate the pump if it is damaged or appears to be malfunctioning.
- Halten Sie Kinder und unbefugtes Personal während des Betriebs von der Pumpe fern.
- Sorgen Sie für eine ordnungsgemäße Erdung, um Stromschläge zu vermeiden.
- Die Pumpe darf nicht für brennbare oder ätzende Flüssigkeiten verwendet werden.
3. Produktüberschreitungview und Komponenten
The Pinyue LRS32-6G 130 circulation pump consists of several key components designed for reliable performance.

- Pumpenkörper: Das Hauptgehäuse der Pumpe.
- Einlass: Connection point for water entering the pump.
- Auslauf: Connection point for water exiting the pump.
- Einstellknopf: Used to select the operating speed/power of the pump.
- Vent Bolt: Für releasing air from the pump system during initial setup or maintenance.
- Anschlussdose: Houses the electrical connections.
4. Installation
Proper installation is crucial for the pump's performance and longevity. Consult a qualified technician if you are unsure about any steps.
4.1 Prüfungen vor der Installation
- Überprüfen Sie, ob die Spezifikationen der Pumpe (Volumen)tage, flow, head) match your system requirements.
- Ensure the installation location is dry, well-ventilated, and protected from freezing temperatures.
- Confirm that the distance between the pump's inlet and outlet connections (mouths) is 130mm, as required for proper fitting in many systems.
4.2 Montage der Pumpe
- Mount the pump securely to a stable surface, ensuring it is level.
- The pump can be installed in either horizontal or vertical piping, but ensure the motor shaft is horizontal to prevent premature wear.
4.3 Sanitäranschlüsse
- Connect the pump to the piping system using appropriate fittings. The pump has a 2-inch diameter connection.
- Use thread sealant on all pipe connections to prevent leaks.
- Ensure that isolation valves are installed on both sides of the pump to facilitate future maintenance without draining the entire system.
4.4 Elektrische Anschlüsse
- The pump operates on 220V/50Hz power. Ensure your electrical supply matches these requirements.
- All electrical wiring must be performed by a licensed electrician and comply with local electrical codes.
- Connect the power supply to the junction box, ensuring proper grounding.
- Überprüfen Sie, ob alle Verbindungen fest und sicher sind.
5. Bedienung
Once installed, the pump is ready for operation. Follow these steps for initial startup and normal use.
5.1 Erstinbetriebnahme
- System ausfüllen: Ensure the entire heating or circulation system is filled with water and all air has been bled from the system.
- Vent the Pump: Loosen the vent bolt (refer to Figure 2) slightly until water begins to flow out, indicating that air has been expelled from the pump casing. Tighten the vent bolt.
- Kraft anwenden: Turn on the electrical supply to the pump.
- Auf Lecks prüfen: Inspect all connections for any signs of leakage.
5.2 Adjusting Pump Speed
The pump features a three-speed adjustment knob, allowing you to optimize performance for different system demands.

- Rotate the adjustment knob (refer to Figure 2) to select the desired speed setting.
- Higher speeds provide greater flow and head, suitable for larger systems or higher demand.
- Lower speeds consume less energy and are ideal for maintaining circulation in smaller systems or during periods of lower demand.
5.3 Anwendungen

This pump is versatile and can be used in various scenarios:
- Floor Heating Circulation: Ensures even heat distribution throughout floor heating systems.
- Radiator Circulation: Facilitates efficient hot water flow to radiators.
- Water Heater Circulation: Improves hot water delivery from water heaters.
- Water Tank Circulation: Maintains consistent water temperature in storage tanks.
- Apartment Pressurization: Boosts water pressure in residential settings.
- Solar Pressurization: Supports solar hot water systems.
6. Wartung
Regular maintenance helps ensure the long-term reliability and efficiency of your circulation pump.
- Jährliche Inspektion: Periodically check the pump for any signs of wear, corrosion, or damage.
- Auf Lecks prüfen: Überprüfen Sie regelmäßig alle Rohrverbindungen auf Undichtigkeiten und ziehen Sie diese gegebenenfalls fest.
- Belüftung: Ensure the pump area remains well-ventilated to prevent overheating.
- Systemspülung: If your heating system accumulates debris, consider flushing the system to prevent blockages in the pump.
- Überwinterung: If the pump is in an area prone to freezing, ensure the system is properly drained or protected from freezing temperatures during cold periods.
7. Fehlerbehebung
Hier sind einige häufige Probleme und ihre möglichen Lösungen:
- Pumpe startet nicht:
- Check power supply and electrical connections.
- Ensure the motor is not seized (try rotating the shaft manually if accessible, with power off).
- Low Flow or No Flow:
- Check for air in the system; re-vent the pump.
- Stellen Sie sicher, dass die Absperrventile vollständig geöffnet sind.
- Inspect for blockages in the piping or pump impeller.
- Verify the pump speed setting is appropriate for the system demand.
- Übermäßiger Lärm/Vibration:
- Check for air in the system; re-vent the pump.
- Stellen Sie sicher, dass die Pumpe sicher montiert ist.
- Inspect for foreign objects in the impeller.
- Check for cavitation (insufficient water supply to the pump).
Sollten die Probleme weiterhin bestehen, wenden Sie sich bitte an den Kundendienst oder einen qualifizierten Techniker.
8. Spezifikationen

| Attribut | Wert |
|---|---|
| Modellnummer | LRS32-6G 130 |
| Markenname | Pinyue |
| Herkunft | Festlandchina |
| Anwendung | Familienhäuser |
| Druck | Hochdruck |
| Leistung (W) | 93/67/48 (Three-speed) |
| Max Flow (L/min) | 55/40/25 (Three-speed) |
| Max. Förderhöhe (m) | 6/5/3 (Three-speed) |
| Bandtage (V) | 220V/50Hz |
| Durchmesser (Zoll) | 2" |
| Motor | 100% pure copper |
| Stromquelle | Elektrisch |
| Struktur | Einzeltage Pump (Shielded circulating pump) |
| Material | Gusseisen |
| Welle | Stainless Steel Welded Shaft |
| Distance between mouths | 130 mm |
9. Benutzertipps
- Check Dimensions Carefully: Vor dem Kaufasing or installing, always confirm the distance between the pump's inlet and outlet connections (130mm for this model) to ensure compatibility with your existing plumbing.
- Optimize with Speed Adjustment: Utilize the three-speed adjustment feature to balance energy consumption and performance. A lower speed might be sufficient for maintaining circulation, while a higher speed can address peak demand.
- Genießen Sie den leisen Betrieb: This pump is designed for silent operation, making it suitable for household environments without causing disruptive noise.
10. Garantie und Support
The Pinyue LRS32-6G 130 Hot Water Circulation Pump comes with a 1-year warranty from the date of purchase, covering manufacturing defects. Please retain your proof of purchase for warranty claims.
For technical support, troubleshooting assistance, or warranty inquiries, please contact our customer service team:
- Verkaufsleiter: Miss Han
- WhatsApp: +86 13973647302
- WeChat: Lsh200521-
- E-Mail: 2775014343@qq.com
- Telefon: +86 13973647302